PubMed Health⌕ Search

Biomedical subjects

S Stea

Publications and source records attributed to S Stea.

At least 37 records · Page 2Linked to original sources

Sister chromatid exchange in patients with joint prostheses.

The evaluation of sister chromatid exchanges (SCE) is used to establish the cytogenic damage in subjects exposed to toxic substances. The test is considered to be 1 of the most sensitive and accurate indicators of damage and responds to toxic chemicals at low doses. We evaluated the incidence of SCE in peripheral lymphocytes of patients with articular prostheses. Subjects with prostheses made of titanium-aluminium-vanadium alloys presented a significantly higher SCE number than the control population (6.3+/-2.3 vs 4.4+/-1.3; P = .0128), whereas subjects with prostheses made of chrome-cobalt alloy or mixed prostheses presented a higher SCE value than the controls but not significantly different. The presence of high-frequency cells was alarming only in 5 patients, 4 of whom had titanium alloy prostheses, whereas none belonged to the control group. The number of SCE was not affected by the presence of bone-cement used in prosthesis fixation or by the implant duration. The indication of possible cytogenic damage in patients with titanium alloy prostheses that emerged from this study should be considered carefully, even though the sample population was small.

Adult↗

In vitro investigation of aluminum and fluoride release from compomers, conventional and resin-modified glass-ionomer cements: a standardized approach.

The amount of fluoride release from dental cements necessary for an anticariogenic effect is not established: moreover, the possible toxic effects due to high fluoride and aluminum release are not well known and the results are still controversial. The aim of our study was to evaluate fluoride (F) and aluminum (Al) release from dental cements using a 'standardized approach' according to the end-use of the materials, i.e. biocompatibility testing. Two polyacid-modified resin composites of recent application, commonly called compomers (Dyract and Dyract Cem), were compared with two conventional acid-based (Fuji I, Ketac-Cem) and two resin-modified (Vitremer, Vitrebond) glass-ionomer cements (GICs). All types of cement are used in dentistry and are commercially available. Extracts of the cements into minimum essential medium, after setting over a 1-h (group A) and 1-week (group B) period, were performed. The extraction conditions were rigorously standardized. Mean values +/- standard deviation of F- and Al-levels in such extracts were measured and were expressed as microg g(-1) (micrograms of ions per gram of cement). A great difference in the amount of ion release, both F and Al, was shown among the tested materials. The GICs, as well as Ketac-Cem, released more F and Al than the compomers. All of the materials released the greatest proportion of ions when the extraction was performed in the first hour after mixing (group A). Al- and F-values showed a highly significant positive correlation, independently from the curing time. We conclude that the biological assessment of dental cements can be performed only if a pre-evaluation of the leachables is obtained by applying a standardized protocol which allows a useful comparison between the different materials.

Aluminum↗

In vitro testing of ten bone cements after different time intervals from polymerization.

Biological response of cells to implanted bone cement is a fundamental but often neglected issue in successful cemented implants. In this study, ten acrylic bone cements for orthopedics were assayed using two different in vitro testing methods on L929 cells. The cements were mixed as prescribed, cured for either 1 h or 7 days and then extracted in minimum essential medium (MEM) according to the ISO standard for the preparation of samples. For the evaluation of cytotoxicity, the neutral red uptake assay (NRU) and the incorporation of propidium iodide (PI) were used to detect the viability/death of cells. The two methods were shown to be well correlated (p < 0.0001) in the case of both the 1-h and the 7-day extracts. Two cements, i.e. CERIM LT and CMW2, were found to be toxic after 1-h curing through both the spectrophotometric NRU assay and the cytofluorometric assay with PI. After 7-day curing, these two cements, as well as the Zimmer-low viscosity cement, were toxic according to the NRU assay. The toxic effect of all the cements disappeared after dilution of extracts 1:2 with MEM, except in the case of CERIM LT. In the search for the component inducing the toxic effect, the possible contribution of the residual monomer was discarded on the basis of literature data and the influence of various other factors was analyzed, including the contrast medium (barium sulphate or zirconium dioxide) and the concentrations of N,N-dimethyl-paratoluidine and of benzoyl peroxide (< 1% or > or = 1%). Unlike zirconium dioxide, barium sulphate was found to damage the cells at the 1-h endpoint. Benzoyl peroxide at concentration > or = 1% was found to affect cells at the same endpoint, whereas dimethylparatoluidine had no effect regardless of the proportion.

Animals↗

Modulation of pro- and anti-apoptotic genes in lymphocytes exposed to bone cements.

The ability of bone cements to modify the apoptotic program in activated immune cells and the mechanisms by which they act were evaluated. Mononuclear cells were collected from healthy individuals, cultured for 4 and 24 h with phytohemoagglutinina-P and cement extracts and then tested to assess: (a) cell viability; (b) early apoptotic events, by Annexin V/propidium iodide staining; and (c) the expression of pro- (p53, c-myc, ICE) and anti-apoptotic (bcl-2) genes. After 4 h three cements were able to increase significantly the percentage of apoptotic cells, while after 24 h no differences were found. The proportion of dead cells was not significantly changed at either culture time. The simultaneous expression of both pro-apoptotic (ICE, c-myc, p53) and antiapoptotic genes (bcl-2) was investigated only with regard to the materials which induced significant changes in apoptosis: two cements induced the p53 expression, while the third down-regulated bcl-2. As apoptosis regulates the balance of immune response, the authors recommend that the interaction between materials and immune cells should be assessed, so that the use of pro-apoptotic materials may be avoided in patients with immune defects.

Annexin A5↗

Biocompatibility and performance in vitro of a hemostatic gelatin sponge.

The biocompatibility of a hemostatic gelatin sponge (Cutanplast Standard) was evaluated in vitro. Cytotoxicity was assessed by neutral red uptake and amido black staining tests; genotoxicity was assayed using the Ames test, Sister Chromatides Exchanges (SCE) and chromosomal aberrations. The ability of the hemostatic gelatin sponge to induce platelet adhesion and release reaction was also determined. The undiluted extract of the test material was found to be cytotoxic, but cell viability was not affected by 1:2 and 1:10 diluted extract. The same extract was found to be non-genotoxic using the three assays for genotoxicity. A significant decrease of platelet number, as well as a significant release of platelet factor 4 was found to be caused by the solid material. In conclusion, Cutanplast Standard is neither cytotoxic nor genotoxic, while inducing platelet adhesion and release reaction when challenged with blood.

Absorbable Implants↗

Effects of metal ions on white blood cells of patients with failed total joint arthroplasties.

In this study twenty-two patients who had revision surgery for aseptic loosening of joint prostheses were examined. The concentration in serum of soluble products of corrosion from the implant, that is, chromium (Cr), cobalt (Co), and nickel (Ni) ions, and the number of white blood cells (leucocytes, myeloid cells, lymphocyte subpopulations) were measured. Twenty patients with no implants were used as controls. The patients who had revision surgery showed normal Ni concentration whereas by statistical analysis that same patient group was shown to have serum Cr and Co levels significantly higher than those of the control. By flow cytometry, a significant decrease of leucocytes, myeloid cells, lymphocytes, and CD16 populations as found in patients versus controls whereas CD3, CD4, CD8, and CD20 positive cells were decreased, but not significantly. In the arthroplasty patients the Cr concentrations were inversely correlated with some of the immunologic parameters while no significant correlation was found between Co levels and decreased lymphocyte subpopulations. Only in revision surgery patients with high Cr concentrations did we find a significant decrease of lymphocytes, namely of CD4 and CD16 positive cells; revision surgery patients with normal Cr concentrations did not show a significant decrease of lymphocyte subpopulations. These data suggest that the presence of metal ions, especially chromium, released from prosthesis components could be associated with changes of lymphocyte subpopulations in patients with loosening of joint prostheses.

Adult↗

Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis.

The aim of this study was the evaluation of the release of bone-resorbing cytokines in peripheral blood mononuclear cells (PBMC) of patients with aseptic loosening of Co-Cr hip prostheses. TNF-alpha, IL-6, and GM-CSF were measured in both unstimulated and PHA-stimulated PBMC, and in PBMC cultured in the presence of chromium and cobalt extracts. Blood samples from healthy donors were used as controls. Serum samples of both patients and healthy donors were tested to determine the concentration of metal ions. The proportion of lymphocyte, monocyte and lympocyte subpopulation in cultured PBMC did not differ in patients and the control group. In unstimulated PBMC the release of TNF was significantly higher in patients than in the control group, while IL-6 was significantly decreased and no change was observed for GM-CSF. When the PBMC were challenged with chromium extract, all the 'index of cytokine release' resulted higher in patients than in the control group; cobalt extract increased both the TNF and GM-CSF index, but not the index of IL-6 release. Metal concentrations in serum from patients were significantly increased and correlated with the TNF release in PBMC stimulated with both metal extract. Our results suggest that a CoCr-implant releases a large amount of metal ions which could mediate the priming or the renewal of a cell-mediated hypersensitivity reaction. The prevalence of circulating lymphocytes responsible for the delayed hypersensitivity, namely Thl, would justify both the significant increase of TNF and the significant decrease of IL6 in unstimulated PBMC of patients, as well as the significant increase of the 'index of cytokine release' after the challenge with metal ions.

Adult↗

Wear debris and cytokine production in the interface membrane of loosened prostheses.

In this study, thirty-nine patients were examined. All of them suffered from hip joint prostheses loosening and underwent revision surgery. Bioptic samples were collected at the interface between bone and implant either at the stem or cotyle level. Immunohistochemistry was performed to detect IL-1alpha, IL-1beta, IL-6 and TNF, cytokines that directly cause bone resorption and indirectly induce synthesis of other bone resorbing cytokines. Quantitative analysis of the positive cells and correlation with clinical data was performed. It resulted that there is a great variability in positive cells for cytokines according to the harvest site; anyway, cytokines tend to be higher in patients carrying a joint prosthesis with polyethylene acetabular component and it is associated with plastic wear particles, even though there is no direct correlation between wear amount and cytokine levels. There is a statistically significant negative correlation between metal wear and a cytokine (IL-6); cytokines levels do not depend on the implant time to failure and do not correlate with pain score. As expected, cytokines levels tend to be lower in subjects being treated with non-steroidal antiinflammatory drugs. It can be concluded that plastic wear is the factor inducing the highest cytokine levels in the tissues around the prosthesis at the interface; cytokines that are an indicator of osteolysis risk.

Adult↗

Hydroxyapatite fully coated conic hip prosthetic stem: a long term animal study.

The purpose of this paper is to evaluate in an animal model the long term results obtained with a prosthetic stem fully coated with hydroxyapatite. The cup was manufactured in polyethylene and was cemented. Six arthroplasties were performed in six sheep. After twelve months, the animals were euthanized and the femurs were harvested and processed for undecalcified sectioning. Twelve cross sections were cut perpendicularly to the longitudinal stem axis. Sections one to five corresponded to the area of the stem which, at the time of surgery, had a full initial contact between the bone and the prosthesis; sections six to ten corresponded to the area of the stem which, at the time of surgery, had a gap from 0 to 2 mm between the bone and the prosthesis; sections eleven and twelve had an initial gap larger than 2 mm. At one year after implantation, in the sections one to five, morphological analyses showed extensive direct contact between the bone and the hydroxyapatite coating. Bone prosthesis contact was lower in the sections six to ten. No contact was seen in sections eleven and twelve. Comparing bone to prosthesis contact of each subsequent section, from proximal to distal, the difference becomes significant with section five compared to section six (p < 0.00005). No detachment of the hydroxyapatite coating from the metallic substrate was observed in any section. In conclusion, this study shows that a conic shaped femoral stem, fully coated with hydroxyapatite gives very good histological and histomorphometric results at one year. Prosthesis osteointegration showed to be influenced by the initial bone to prosthesis contact. No direct bone to prosthesis contact was achieved if the initial bone to prosthesis gap was larger than 2 mm.

Animals↗

Cytotoxicity testing of materials with limited in vivo exposure is affected by the duration of cell-material contact.

Silicones for dental impression largely are used to record the geometry of hard and soft dental tissues. They are considered to be medical devices, and the assessment of cytotoxicity is a necessary step in the evaluation of their biocompatibility. Extracts of six addition-type and six condensation-type silicones have been tested with L929 cells according to the ISO 10993-Part 5 standard. The cytotoxicity was evaluated by three different methods: neutral red uptake, propidium iodide (PI) staining, and amido black staining. According to the selected specific assay, contact between cells and material extracts was maintained for 24 h in the first series of experiments; then, considering that in vivo application of these materials is restricted to a few minutes, additional experiments were performed after 1 h of cell/extract contact. Analysis of the results showed that the addition-type silicones are nontoxic even when tested after prolonged exposure of the cells to the materials while the condensation-type silicones were cytotoxic at 24 h of incubation. Nevertheless, harm to the patient actually could be negligible, considering its very short time of exposure in vivo. This is supported by our finding that most are not toxic after 1 h. We suggest that the experimental conditions of cytotoxicity testing have to be relevant to the in vivo situation; accordingly, the time of exposure should be designed carefully.

Amido Black↗

In vitro sister chromatid exchange induced by glass ionomer cements.

The genotoxicity of three glass ionomer cements used in dentistry, manufactured by American (Vitrebond), Japanese (Fuji I), and European (Ketac Cem) companies were examined. The cement components were mixed according to the manufacturers' instructions and allowed to set for two defined times: 1 h or 1 week, before extracting them, as established by ISO standard 10993 part 12. To highlight sister chromatid exchange during mitosis, the extracts then were tested with human peripheral lymphocytes in the presence or absence of metabolic activation with S9 mix. The test performed was a genotoxicity test as provided for in standard EN 30993 part 3. Vitrebond resulted in direct genotoxicity and was strongly cytotoxic both in the extracts performed at 1 h and those at 1 week if they were allowed to set without photoactivation. Fuji I was noncytotoxic and showed only uncertain indirect genotoxicity in the extracts at 1 h; genotoxicity was not present in the extracts at 1 week. Ketac Cem cement was not genotoxic nor was it cytotoxic either at 1 h or 1 week. The authors concluded that of the three cements tested the European cement Ketac Cem passed one of the tests suggested by the EEC standard for assessing genotoxicity.

DNA Damage↗

False positive results in cytotoxicity testing due to unexpectedly volatile compounds.

We investigated the cytotoxicity of different dental materials according to the study protocol adopted by our lab for the screening of new materials. Experimental parameters used in such testing are addressed mainly in documents EN 30993 "Biological evaluation of medical devices, Part 5: Tests for cytotoxicity: in vitro methods" and "Biological evaluation of medical devices, Part 12: Sample preparation and reference materials." Cells were cultured in microplates and challenged with aqueous extracts of the materials. The assay methods were neutral red- and propidium iodide-uptake assays, both indicative of cell viability and able to provide quantitative data. The observation of contrasting results for one material using the above-mentioned methods raised some concern about the assay system used. With further experimentation, it appeared that a sustained release of volatile substances still present in one extract exerted a toxic effect in neighboring cultures. It is concluded that in the microenvironment of a microplate the distribution of samples cannot be disregarded, as it may be responsible for toxicity cross-contamination. Moreover, the use of more than one single method has to be recommended in cytotoxicity testing, in order to avoid false positive results due to experimental artifacts.

Animals↗

The interface of bone microstructure and an innovative coating: an X-ray diffraction study.

The in vivo compatibility and degradation aspects of an innovative coating to be sprayed onto titanium implants were investigated. The surface of fluorinated apatite (fHA), consisting of fluorhydroxyapatite plasma sprayed in a vacuum atmosphere, was treated with carbonate to improve its biological compatibility. fHA coating was compared with titanium implants coated (a) with hydroxyapatite (HA) by the traditional plasma spraying, and (b) with titanium oxide (TiOx). Screw-shaped implants were inserted in the cortical bone of sheep tibiae. X-ray diffraction (XRD) analysis of bone tissue and coatings was carried out at 2, 4, 12 and 36 weeks after surgery. The crystallographic habit of the implant-facing bone, as well as the structural stability of the coating, were evaluated. For each time period and type of ceramic bone apatite lattice at the interface, no significantly different reference apatite lattice and no foreign peak were recorded. Two weeks after implantation, the bone at the interface was strongly unmineralized in all samples; after 4 weeks, poorly mineralized bone microareas decreased. At 12 weeks, the newly formed bone tissue at the interface with both the new coating and HA coating was shown to be fully mineralized; this crystallographic habit was retained at 36 weeks, when particle release from the tested material was lower compared to the controls. The XRD pattern of bone apatite surrounding the coating particles was unmodified. The innovative coating did not alter the mineralization process at the interface. It improved implant osteointegration, mainly due to a limited release of particles. Consequently, clinical performance of external fixation treatment could be improved by modifying the chemical composition of the implant surface.

Animals↗

Detection of mutagenic potential of some glass-ionomer cements through Ames testing.

The mutagenic potential of three commercially available glass-ionomer cements used in dentistry was examined. The cement components were mixed according to the manufacturers indications and set for two defined times: 1 h or, alternatively, 1 wk. Cements B and C set spontaneously; in the case of cement A, the manufacturer suggests the use of a lamp to trigger also a photopolymerization. Photopolymerization, however, was not used. Ames tests were performed on the dimethyl sulphoxide extracts of cements by using Salmonella typhimurium strains TA 98, TA 100, TA 1535, TA 1537, TA 1538 and TA 102. Cement A showed mutagenicity only against TA 1537 strain, either in the presence or absence of metabolic activation with microsomial fraction S9. The other two cements showed no mutagenic potential. We conclude that glass-ionomer cements are, on the whole, safe materials from the viewpoint of genotoxicity, and hypothesize that the mutagenicity observed in cement A could depend on its polymerization performed without light activation.

Journal Article↗

X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants.

The microstructural characteristics of the newly formed bone tissue at the interface with hydroxyapatite-coated and uncoated stainless steel pins used in an external fracture fixation system have been evaluated. The bone far from the interface was used as a control. Pins were transversally inserted into the diaphyses of sheep tibiae and were loaded in for six weeks. Three sheep received coated pins and two received uncoated pins. Crystallographic habit and mineralization of the implant-facing bone were evaluated. Moreover, lattice parameters of bone apatite were measured and hydroxyapatite (HA) coating degradation was investigated, by means of conventional and microbeam X-ray diffraction (XRD). In coated pins, six weeks after the implantation the newly formed bone tissue at the interface did not reach complete maturation, but the presence of the implant did not alter the apatite lattice structure; the lattice parameters did not show statistically significant variations with respect to those observed in the control bone. In uncoated pins, bone tissue rarely appeared totally mineralized and lattice parameters were significantly different with respect to those observed in the bone far from the implant. HA particles were observed spreading in the bone-facing coated pins; the XRD pattern of bone apatite surrounding HA particles was unmodified. It was concluded that HA coatings improved the bone remodelling process during pin fixation in comparison to uncoated pins and did not alter the crystallographic habit of apatite.

Journal Article↗

Cell death induced by metal ions: necrosis or apoptosis?

We have evaluated if the cytotoxic effects of metals released from implants are due to necrosis or apoptosis. Peripheral blood mononuclear cells were exposed to different concentrations of chromium, nickel and cobalt extracts and the characteristics of both apoptosis and necrosis were evaluated by flow-cytometry at different culture endpoints. In order to define the prevalence of apoptosis or necrosis, the ratio cell death/apoptosis was calculated. A ratio of </=1 means the prevalence of apoptotic events; a ratio >1 indicates the acute toxicity of the tested substance (necrosis). The extracts of chromium, cobalt and nickel had a cytotoxic effect on the mononuclear cells; high concentrations of cobalt and nickel produced cell necrosis, whereas by lowering the extract concentration apoptotic phenomena were observed. High chromium concentrations can induce cell death by apoptosis. Our data suggest that when large amounts of nickel and cobalt are released from implanted metal devices, necrosis is produced and consequently a strong inflammatory tissue reaction is likely to occur. The release of either chromium or limited amounts of nickel and cobalt induces toxicity characterized by apoptotic phenomena, which allows an adaptation of the tissue to the implant.

Journal Article↗

Bone-resorbing cytokines in serum of patients with aseptic loosening of hip prostheses.

Our aim was to determine if the serum levels of bone-resorbing cytokines (IL-1beta, TNF-alpha, IL-6, GM-CSF) are altered in patients with aseptic loosening of a total hip prosthesis, and if such levels are influenced by the type of implant. We determined cytokine levels in sera from 35 patients before revision for failed total hip arthroplasty and compared them with those in 25 healthy donors. We also assessed the soluble receptor of interleukin-2 (sIL-2r) in serum as an indication of a specific immune reaction against the implant. Our findings showed that the sIL-2r and TNF-alpha serum level did not change. The IL-6 level was not significantly altered, but was higher in patients with TiAIV prostheses than in those with a CrCoMo implant and in patients with cemented prostheses. The IL-1beta level was found to be higher in those with a TiAIV cemented prosthesis than in the control group (p=0.0001) and other groups of patients (p=0.003 v uncemented TiAIV, p=0.01 v cemented CrCoMo, p=0.001 v uncemented CrCoMo). The GM-CSF level significantly increased in patients compared with healthy subjects (p=0.008), and it was higher in those with cemented than with uncemented implants (p=0.01). Only patients with cementless CrCoMo prostheses had levels of GM-CSF similar to those of the control group. The highest GM-CSF concentrations were observed in patients treated with non-steroidal anti-inflammatory drugs (NSAIDs) in the last months before revision (p=0.04). In addition, when massive osteolysis was observed, the level of GM-CSF tended to decrease to that of the control group.

Acetabulum↗

A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins. An in vivo study in sheep.

Three types of surfaces for external fixation pins were compared. One hundred and eight stainless-steel tapered 5/6-millimeter pins were divided into three groups: thirty-six pins remained uncoated (Group A), thirty-six were plasma-sprayed with hydroxyapatite (Group B), and thirty-six were plasma-sprayed with titanium (Group C). The pins were implanted in the left tibia of eighteen sheep, with each sheep receiving six pins from the same group. A unilateral fixator then was assembled on the pins. The medial aspect of the mid-part of the tibial diaphysis was exposed, and a five-millimeter-long cylinder of bone was removed so that load would be borne by the bone-pin interfaces. Six weeks after the procedure, radiographs demonstrated rarefaction of twenty-nine pin tracks in Group A, fifteen in Group B, and thirty in Group C (p = 0.021 for Group A compared with Group B and p = 0.016 for Group B compared with Group C). The mean final insertion torque (and standard deviation) was 4360+/-1050 newton-millimeters in Group A, 3420+/-676 newton-millimeters in Group B, and 3740+/-643 newton-millimeters in Group C. With the numbers available, no significant differences could be detected among these values. The mean extraction torque was 253+/-175 newton-millimeters in Group A, 3360+/-1260 newton-millimeters in Group B, and 1720+/-1030 newton-millimeters in Group C (p = 0.002 for Group A compared with Group B, p = 0.017 for Group A compared with Group C, and p = 0.03 for Group B compared with Group C). The extraction torque was significantly lower than the corresponding insertion torque in both Group A (p < 0.001) and Group C (p = 0.003); no significant difference could be found, with the numbers available, in Group B (hydroxyapatite-coated pins). At sixty times magnification, direct contact was seen along a mean of 16+/-9 per cent of the bone-pin interface in Group A, 30+/-12 per cent of the interface in Group B, and 28+/-15 per cent of the interface in Group C (p = 0.042 for Group A compared with Group C). However, at 10,000 times magnification, direct bone-pin contact was found only in Group B.

Animals↗