Error reduction and parameter optimization of the TAPIR method for fast T1 mapping.

A methodology is presented for the reduction of both systematic and random errors in T(1) determination using TAPIR, a Look-Locker-based fast T(1) mapping technique. The relations between various sequence parameters were carefully investigated in order to develop recipes for choosing optimal sequence parameters. Theoretical predictions for the optimal flip angle were verified experimentally. Inversion pulse imperfections were identified as the main source of systematic errors in T(1) determination with TAPIR. An effective remedy is demonstrated which includes extension of the measurement protocol to include a special sequence for mapping the inversion efficiency itself.

Algorithms↗

Fast T(1) mapping with volume coverage.

Four different sequences which enable high-resolution, multislice T(1) relaxation-time mapping are presented. All these sequences are based on the Look-Locker method with differences arising from the use of either a saturation-recovery or inversion-recovery module prior to data acquisition with a full k-space or banded k-space acquisition scheme. The methods were implemented on a standard clinical scanner and the accuracy of the T(1) results was evaluated against spectroscopic measurements. The accuracy of the T(1) maps validated by phantom imaging measurements is around 1% for species which relax with T(1) times that mimic gray/white matter (T(1) < or = 1000 ms). Additionally, the inherent multislice, multipoint capability of the methods is demonstrated. Finally, in vivo results of the human brain obtained using the faster method are presented. The fastest data acquisition was achieved with a saturation-recovery, banded k-space method where k-space was divided into three segments; an overall acquisition time of around 5 min (for species with T(1) < or = 1 sec) was achieved for a T(1) map which can, in principle, provide whole-brain coverage with a matrix size of 256 x 256 at multiple time-points. Magn Reson Med 46:131-140, 2001.

Brain↗

A new method for fast multislice T(1) mapping.

A sequence for T(1) relaxation-time mapping which enables high-resolution, multislice imaging in short acquisition times is presented. The sequence is based on the Look-Locker method and employs a magnetization-preparation module prior to data acquisition with a banded k-space data collection scheme. The method was implemented on a standard clinical scanner and the accuracy of the T(1) results was evaluated against spectroscopic measurements. The accuracy of the T(1) maps validated by phantom imaging measurements is <3% for slow-relaxing compartments (T(1) congruent with 2000 ms) and is around 1% for faster-relaxing species (T(1) < or = 1200 ms). Additionally, the inherent multislice, multipoint capability of the method is demonstrated. Multislice, multipoint in vivo results of the human brain obtained using this method are presented. An acquisition time of approximately 8 min was achieved for a T(1) map, which, in principle, can provide whole-brain coverage with 25 slices, a matrix size of 256 x 256, and 12 time points. The speed of the sequence is derived through optimized interleaving of slices and time points, together with the acquisition of multiple echoes, which are used to fill a 3-segment k-space.

Brain↗

The effect of sequence repeat time on auditory cortex stimulation during phonetic discrimination.

Acoustic noise generated by the MR scanner gradient system during fMRI studies of auditory function is a very significant potential confound. Despite these deleterious effects, fMRI of the auditory cortex has been successful and numerous practitioners have circumvented the problem of acoustic masking noise. In the context of auditory cortex fMRI, the sequence repeat time (TR) has the effect of altering the length of time during which the scanner is quiet. Indeed, the move to whole-brain fMRI makes the problem of acoustic noise more acute and points to the need to examine the role of TR and its influence on the BOLD signal. The aim of this study was to examine the effect of varying the TR time on activation of auditory cortex during presentation and performance of a phonetic discrimination task. The results presented here demonstrate that the influence of sequence repeat time is considerable. For a short repeat time it is likely that the noise from the scanner is a significant mask and hinders accurate task performance. At the other extreme, a repeat time of 9 s is also suboptimal, probably due to attentional effects and lack of concentration and not least because of the longer overall measurement times. The results of this study point to a complicated interplay between psychophysical factors as well as physical parameters; attention, acoustic noise, total duration of the experiment, consideration of the volume of acquisition, and overall difficulty of the task have to be assessed and balanced. For the paradigm used here, the results suggest an optimal TR of around 6 s for a 16-slice acquisition.