This case report describes a patient who presented with pyrexia of unknown origin allied with hypertriglyceridaemia (16.2 mmol/l) but not hypercholesterolaemia (4.1 mmol/l). Investigations identified the cause of the pyrexia as an adult T-cell lymphoma of natural killer cell phenotype (CD3[+], CD7[+], anti-TCR alpha/beta[+], CD8[+], CD56[+]). Hypertriglyceridaemia has been reported with non-Hodgkin s lymphoma, and an animal model suggests that antilipoprotein lipase antibodies may be made as an immunological response to the tumour. Lymphomas should be considered as part of the differential diagnosis in type IV-V hyperlipidaemia.

Adult↗

Architecture of the rectus abdominis, quadratus lumborum, and erector spinae.

Quantitative descriptions of muscle architecture are needed to characterize the force-generating capabilities of muscles. This study reports the architecture of three major trunk muscles: the rectus abdominis, quadratus lumborum, and three columns of the erector spinae (spinalis thoracis, longissimus thoracis and iliocostalis lumborum). Musculotendon lengths, muscle lengths, fascicle lengths, sarcomere lengths, pennation angles, and muscle masses were measured in five cadavers. Optimal fascicle lengths (the fascicle length at which the muscle generates maximum force) and physiologic cross-sectional areas (the ratio of muscle volume to optimal fascicle length) were computed from these measurements. The rectus abdominis had the longest fascicles of the muscles studied, with a mean (S.D.) optimal fascicle length of 28.3 (4.2)cm. The three columns of the erector spinae had mean optimal fascicle lengths that ranged from 6.4 (0.6)cm in the spinalis thoracis to 14.2 (2.1)cm in the iliocostalis lumborum. The proximal portion of the quadratus lumborum had a mean optimal fascicle length of 8.5 (1.5)cm and the distal segment of this muscle had a mean optimal fascicle length of 5.6 (0.9)cm. The physiologic cross-sectional area of the rectus abdominis was 2.6 (0.9)cm(2), the combined physiologic cross-sectional area of the erector spinae was 11.6 (1.8)cm(2), and the physiologic cross-sectional area of the quadratus lumborum was 2.8 (0.5)cm(2). These data provide the basis for estimation of the force-generating potential of these muscles.

Aged↗

Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography.

RATIONALE AND OBJECTIVES: The purpose of this study was to comparatively evaluate digital planar mammography and both linear and nonlinear tomosynthetic reconstruction methods. MATERIALS AND METHODS: A "disk" (ie, target) identification study was conducted to compare planar and reconstruction methods. Projective data using a composite phantom with circular disks were acquired in both planar and tomographic modes by using a full-field, digital mammographic system. Two-dimensional projections were reconstructed with both linear (ie, backprojection) and nonlinear (ie, maximization and minimization) tuned-aperture computed tomographic (TACT) methods to produce three-dimensional data sets. Four board-certified radiologists and one 4th-year radiology resident participated as observers. All images were compared by these observers in terms of the number of disks identified. RESULTS: Significant differences (P < .05, Bonferroni adjusted) were observed between all reconstruction and planar methods. No significant difference, however, was observed between the planar methods, and only a marginally significant difference (P < .054, Bonferroni adjusted) was observed between TACT-backprojection and TACT-minimization. CONCLUSION: A combination of linear and nonlinear reconstruction schemes may have potential implications in terms of enhancing image visualization to provide radiologists with valuable diagnostic information.

Breast Neoplasms↗

Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

An amorphous silicon-based full-breast imager for digital mammography was evaluated for detector stability over a period of 1 year. This imager uses a structured CsI:TI scintillator coupled to an amorphous silicon layer with a 100-micron pixel pitch and read out by special purpose electronics. The stability of the system was characterized using the following quantifiable metrics: conversion factor (mean number of electrons generated per incident x-ray), presampling modulation transfer function (MTF), detector linearity and sensitivity, detector signal-to-noise ratio (SNR), and American College of Radiology (ACR) accreditation phantom scores. Qualitative metrics such as flat field uniformity, geometric distortion, and Society of Motion Picture and Television Engineers (SMPTE) test pattern image quality were also used to study the stability of the system. Observations made over this 1-year period indicated that the maximum variation from the average of the measurements were less than 0.5% for conversion factor, 3% for presampling MTF over all spatial frequencies, 5% for signal response, linearity and sensitivity, 12% for SNR over seven locations for all 3 target-filter combinations, and 0% for ACR accreditation phantom scores. ACR mammographic accreditation phantom images indicated the ability to resolve 5 fibers, 4 speck groups, and 5 masses at a mean glandular dose of 1.23 mGy. The SMPTE pattern image quality test for the display monitors used for image viewing indicated ability to discern all contrast steps and ability to distinguish line-pair images at the center and corners of the image. No bleeding effects were observed in the image. Flat field uniformity for all 3 target-filter combinations displayed no artifacts such as gridlines, bad detector rows or columns, horizontal or vertical streaks, or bad pixels. Wire mesh screen images indicated uniform resolution and no geometric distortion.

Female↗

Comparison of tomosynthesis methods used with digital mammography.

RATIONALE AND OBJECTIVES: The authors performed this study to investigate the potential applicability of tomosynthesis to digital mammography. Four methods of tomosynthesis-tuned aperture computed tomography (TACT)-backprojection, TACT-iterative restoration, iterative reconstruction with expectation maximization, and Bayesian smoothing-were compared to planar mammography and analyzed in terms of their contrast-detail characteristics. Specific comparisons between the tomosynthesis methods were not attempted in this study. MATERIALS AND METHODS: A full-field, amorphous, silicon-based, flat-panel digital mammographic system was used to obtain planar and tomosynthesis projection images. A composite tomosynthesis phantom with a centrally located contrast-detail insert was used as the object of interest. The total exposure for multiple views with tomosynthesis was always equal to or less than that for the planar technique. Algorithms were used to reconstruct the object from the acquired projections. RESULTS: Threshold contrast characteristics with all tomosynthesis reconstruction methods were significantly better than those with planar mammography, even when planar mammography was performed at more than twice the exposure level. Reduction of out-of-plane structural components was observed in all the tomosynthesis methods analyzed. CONCLUSION: The contrast-detail trends of all the tomosynthesis methods analyzed in this study were better than those of planar mammography. Further optimization of the algorithms could lead to better image reconstruction, which would improve visualization of valuable diagnostic information.

Breast Neoplasms↗

Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

The physical characteristics of a clinical charge coupled device (CCD)-based imager (Senovision, GE Medical Systems, Milwaukee, WI) for small-field digital mammography have been investigated. The imager employs a MinR 2000 (Eastman Kodak Company, Rochester, NY) scintillator coupled by a 1:1 optical fiber to a front-illuminated 61 x 61 mm CCD operating at a pixel pitch of 30 microns. Objective criteria such as modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), and noise equivalent quanta (NEQ) were employed for this evaluation. The results demonstrated a limiting spatial resolution (10% MTF) of 10 cy/mm. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 40% at close to zero spatial frequency at an exposure of 8.2 mR, and decreases to approximately 28% at a low exposure of 1.1 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Calibration↗

Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Algorithms↗

Fractal analysis of surface EMG signals from the biceps.

Nonlinear analysis techniques are necessary to understand the complexity of the EMG. The purpose of the present study was to determine the fractal dimension of surface EMG obtained from the biceps brachii of normal subjects during isokinetic flexion-extension of the arm. The measurements were obtained with different loading conditions on the arm and for various rates of flexion-extension. Fractal dimensions of the surface EMG signals were calculated for each of these conditions. ANOVA results showed statistically significant differences between the fractal dimensions calculated for different loading conditions and rates of flexion-extensin (P < or = 0.005). Linear regression analysis showed a correlation coefficient of 0.99 between the fractal dimension and the load, and a correlation coefficient of 0.98 between the fractal dimension and the rate of flexion-extension. The results of the study show that the fractal dimension can be used along with other parameters to characterize the EMG signal.

Algorithms↗

An intelligent system with EMG-based joint angle estimation for telemanipulation.

Bio-control of telemanipulators is being researched as an alternate control strategy. This study investigates the use of surface EMG from the biceps to predict joint angle during flexion of the arm that can be used to control an anthropomorphic telemanipulator. An intelligent system based on neural networks and fuzzy logic has been developed to use the processed surface EMG signal and predict the joint angle. The system has been tested on various angles of flexion-extension of the arm and at several speeds of flexion-extension. Preliminary results show the RMS error between the predicted angle and the actual angle to be less than 3% during training and less than 15% during testing. The technique of direct bio-control using EMG has the potential as an interface for telemanipulation applications.

Artificial Intelligence↗

A fuzzy logic diagnosis system for classification of pharyngeal dysphagia.

Identification and classification of the dysphagic patient at risk of aspiration is important from a clinical point of view. Recently, we have developed techniques to quantify various biomechanical parameters that characterize the dysphagic patient, and have developed an expert system to classify patients based on these measurements. The purpose of the present investigation was to develop a fuzzy logic diagnosis system for classification of the patient with pharyngeal dysphagia into four categories of risk for aspiration. Non-invasive acceleration and swallow pressure measurements were obtained and five parameters were extracted from these measurements. A set of membership functions were defined for each parameter. The measured parameter values were fuzzified and fed to a rule base which provided a set of output membership values corresponding to each of the categories. The set of output values were defuzzified to obtain a continuous measure of classification. The fuzzy system was evaluated using the data obtained from 22 subjects. There was a complete agreement between the fuzzy system classification and the clinician's classification in 18 of the 22 patients. The fuzzy system overestimated the risk by half a category in two patients and underestimated by half a category in two patients. The fuzzy logic diagnosis system, together with the biomechanical measures, provides a tool for continued patient assessment on a daily basis to identify the patient who needs further videofluorography examination.

Biomechanical Phenomena↗

Noninvasive acceleration measurements to characterize knee arthritis and chondromalacia.

Devising techniques and instrumentation for early detection of knee arthritis and chondromalacia presents a challenge in the domain of biomedical engineering. The purpose of the present investigation was to characterize normal knees and knees affected by osteoarthritis, rheumatoid arthritis, and chondromalacia using a set of noninvasive acceleration measurements. Ultraminiature accelerometers were placed on the skin over the patella in four groups of subjects, and acceleration measurements were obtained during leg rotation. Acceleration measurements were significantly different in the four groups of subjects in the time and frequency domains. Power spectral analysis revealed that the average power was significantly different for these groups over a 100-500 Hz range. Noninvasive acceleration measurements can characterize the normal, arthritis, and chondromalacia knees. However, a study on a larger group of subjects is indicated.

Acceleration↗