PubMed Health⌕ Search

Biomedical subjects

S T Baksaas

Publications and source records attributed to S T Baksaas.

11 recordsLinked to original sources

[Surgery in chronic pulmonary embolism].

BACKGROUND: Chronic lung thromboembolism may develop after episodes of acute lung emboli. Instead of being resoluted, the thromboembolic material is incorporated into the walls of the lung arteries causing obstruction of the blood flow. Secondarily, pulmonary hypertension develops and patients experience increasing dyspnoea on exertion. In chronic pulmonary thromboembolism, drug therapy is of little benefit. Surgical thromboendarterectomy of lung arteries has emerged as an effective treatment for these very sick patients. MATERIALS AND METHODS: This paper discusses our experience with seven patients who underwent pulmonary thromboendarterectomy during the five-year period 1995-99 at our institution. The preoperative and postoperative haemodynamic evaluation of all patients were similar. RESULTS: For five patients the working capacity was significantly improved, one had limited symptomatic effect, and one died perioperatively due to massive surgical bleeding. INTERPRETATION: Pulmonary thromboendarterectomy may be indicated in selected patients with severe dyspnoea due to pulmonary hypertension secondary to chronic pulmonary thromboembolism.

Adult↗

Sternal wound infections in patients undergoing open heart surgery: randomized study comparing intracutaneous and transcutaneous suture techniques.

BACKGROUND: Intracutaneous suture technique has been our standard method for closing sternal wounds in cardiac surgery, mainly for cosmetic reasons. However, an increased rate of postoperative infections has been reported in cosmetic surgery with this method compared with the percutanous or transcutaneous closure technique. A comparison of these two techniques in cardiac surgery is presented. METHODS: In a randomized study, 300 patients were selected to intracutaneous suture (n = 150) or percutanous suture (n = 150). The endpoints were superficial and deep sternal wound infections within 6 weeks postoperatively. RESULTS: The total infection rate was lower in the percutanous group compared with the intracutaneous group (3% versus 8%) (p = 0.007). The superficial infection rate was lower in the percutaneous group (2.3% versus 6.7%) (p = 0.01), whereas there was no statistically significant difference in the deep infection rate between the groups. CONCLUSIONS: The percutaneous suture technique reduces the incidence of superficial wound infections, but not the deep infection rate in open heart surgery. There was no difference in the cosmetic results on a visual scale, assessed by the patients.

Adolescent↗

[Cardiac tumors].

BACKGROUND: Tumours of the heart are rare, but of great clinical interest as the majority are benign and amenable to radical excision. MATERIAL AND METHODS: We report on 30 patients with cardiac tumours resected at the National Hospital, Oslo, Norway from 1990 to 1999. Data were obtained from patient files. RESULTS: 27 patients had benign tumours, 25 of which were myxomas predominantly located in the left atrium. One patient had a primary malignant tumour (rhabdomyosarcoma) and two had secondary malignant tumours (metastases from malignant tumours). All patients were alive at follow-up four to ten years after operation. INTERPRETATION: Patient with benign tumours are cured by surgery, whereas in malignant primary tumours the surgery will most often be palliative. Surgery for cardiac metastases may be indicated in selected symptomatic patients.

Adolescent↗

In vitro evaluation of new surface coatings for extracorporeal circulation.

Cardiopulmonary bypass (CPB) exposes blood to large, foreign surfaces. This exposure may activate the cellular and humoral inflammatory systems, resulting in inflammatory reactions and organ dysfunction. Coating the inner surfaces of the bypass circuit may help alleviate these side-effects. The objective of this study was to determine the influence of two new surface treatments on blood cell and complement activation. Oxygenator and tubing sets coated with synthetic polymers (n = 7) or heparin (n = 7) were compared to uncoated sets (n = 7) in an in vitro model of CPB. The circuits were run at 4 l/min and recirculated for 120 min. The inflammatory response was assessed at regular intervals by platelet counts, and activation of complement, leucocytes and platelets. We found that the median platelet counts decreased from 127 to 122 x 10(9)/l (not significant, NS) in the synthetic polymer sets, from 96 to 88 x 10(9)/l (NS) in the heparin-coated sets, and from 93 to 54 x 10(9)/l (p < 0.01) in the uncoated sets after 2 h of recirculation. There were significant differences in platelet counts between the coated sets and the uncoated set at end of experiments (p < 0.05). Beta-thromboglobulin (BTG) concentrations increased in the synthetic polymer sets from 166 to 352 ng/ml (p < 0.01), in the heparin coated sets from 336 to 1168 ng/ml (p < 0.01), and in the uncoated sets from 301 to 3149 ng/ml (p < 0.01) after 2 h of recirculation. The differences in BTG at termination of the experiments were significant among all three sets (p < 0.05). Myeloperoxidase (MPO) concentrations in the synthetic polymer sets increased from 63 to 86 micrograms/l (p < 0.01), in the heparin-coated sets from 90 to 208 micrograms/l (p < 0.01), and in the uncoated sets from 122 to 513 micrograms/l (p < 0.01) after 2 h of recirculation. The differences in MPO at termination of the experiments were significant among all three groups (p < 0.01). There were no significant differences at termination of the experiments among the three sets regarding complement activation as measured by C3 activation products and the terminal complement complex. We conclude that in the current in vitro model of a CPB circuit, the synthetic polymer coating and the heparin coating caused significantly less platelet loss and granulocyte and platelet activation than the uncoated surface (p < 0.05). The synthetic polymer coating caused significantly less granulocyte and platelet activation than the heparin coating (p < 0.05). There was moderate complement activation within each group, but no significant differences among the three groups.

Complement Activation↗

Leucocyte filtration during cardiopulmonary reperfusion in coronary artery bypass surgery.

Postoperative organ dysfunction after cardiac operations has been related to the damaging effects of cardiopulmonary bypass (CPB). These complications are considered to be mediated partly by complement activation and subsequent activation of leucocytes due to the contact between blood and the large nonendothelial surfaces in the bypass circuit. Removal of leucocytes by filtration during the reperfusion period may potentially reduce the postoperative morbidity after CPB. Forty patients undergoing elective, primary coronary artery bypass grafting were randomized to initial identical bypass circuits until the aortic crossclamp was released. Then, the ordinary arterial line filter was closed and either a leucocyte depletion filter (n = 20), or a control filter (n = 20) was incorporated in the circuits during the reperfusion period of CPB. Blood samples were drawn at fixed intervals and analysed for white blood cell and platelet counts, plasma concentration of myeloperoxidase, C3-complement activation products, the terminal complement complex, and interleukins (IL)-6 and -8. The numbers of circulating white blood cells in the leucocyte-depleted group decreased during the reperfusion period from 5.5 (4.8-6.8) to 5.3 (4.4-6.2) x 10(9)/l, and increased in the control group from 6.5 (5.1-8.0) to 7.4 (5.7-9.0) x 10(9)/l. Two hours postoperatively the total white blood cell count in the leucocyte-depleted group was 14.7 (12.1-17.2) x 10(9)/l, and in the control group 17.6 (14.5-20.7) x 10(9)/l. The differences between the groups were statistical significant (p = 0.05). There were no statistically significant differences between the groups with regard to other test parameters or clinical data. We conclude that the use of leucocyte filters during the reperfusion period in elective coronary artery bypass surgery significantly reduced the number of circulating leucocytes, whereas no effects were seen for granulocyte activation measured as myeloperoxidase release, platelet counts, complement activation, or IL-6 and -8 release. The clinical benefit of leucocyte filters in routine or high risk patients remains to be demonstrated and is suggested to be dependent on both the efficacy and the biocompatibility of the filters.

Aged↗

Comparison of three oxygenator-coated and one total-circuit-coated extracorporeal devices.

The present study was designed to compare the biocompatibility of three cardiopulmonary bypass setups with different surface coatings, and to determine if coating of the whole circuit with one of the coatings was more beneficial than coating of the oxygenator only. Extracorporeal devices entirely coated with synthetic polymers (Avecor, n = 6) were compared to oxygenators coated with synthetic polymers (Avecor, n = 6), end-point, covalently attached heparin (CBAS, n = 6) or absorbed heparin (Duraflo 2, n = 6) in an in vitro model of a heart lung machine. The circuits were primed with fresh human whole blood and Ringer's acetate and recirculated at 4 l/min at 30 degrees C for 2 h. Test samples were obtained at regular intervals and analysed for myeloperoxidase (MPO), platelet counts, beta-thromboglobulin, heparin, prothrombin fragment 1+2, plasmin anti-plasmin complexes, and complement activation products. The mean MPO concentrations increased in the Avecor-coated oxygenator group (AV) from 247 at the start to 671 microg/l at the termination of the experiments, in the Avecor-coated total circuit group (AV-T) from 116 to 288 microg/l, in the Duraflo 2 coated oxygenator group (DU) from 160 to 332 microg/l, and in the CBAS-coated oxygenator (CA) group from 172 to 311 microg/l. The MPO concentrations increased significantly in all groups (p < 0.03). The increase in group A was significantly higher than in the other three groups (p = 0.007). The mean platelet counts decreased in the Avecor-coated total circuit group from 117 at start to 99 x 10(9)/l at termination of the experiments, in the Avecor-coated oxygenator group from 119 to 103 x 10(9)/l, in the Duraflo 2 group from 96 to 86 x 10(9)/l, and in the CBAS group from 132 to 123 x 10(9)/l. The platelet counts decreased significantly in all groups (p < 0.01), but the intergroup differences were not significant (p = 0.15). The mean beta-thromboglobulin concentrations increased in the Avecor-coated total circuit group from 193 at the start to 754 ng/ml at the termination of the experiments, in the Avecor-coated oxygenator group from 474 to 1654 ng/l, in the Duraflo 2 group from 496 to 1280 ng/l, and in the CBAS group from 418 to 747 ng/l. The beta-thromboglobulin increase was significant in each group (p < 0.01), but not between the groups (p = 0.49). The mean heparin concentrations in the Duraflo 2 group increased from 2460 at the start to 2897 IU/l at termination of the experiments, in the CBAS group from 2468 to 2518 IU/l. In the Avecor-coated oxygenator group heparin concentrations decreased from 2010 to 1968 IU/l, and in the Avecor-coated total circuit group from 2002 to 1927 IU/l. The differences in heparin concentrations were significant between the Duraflo 2 group and the other groups (p < 0.05). The mean prothrombin fragment 1+2 concentrations increased in the CBAS group from 0.4 at the start to 2.1 nmol/l at the end of the experiments, in the Avecor-coated oxygenator group from 0.4 to 0.6 nmol/l, in the Avecor-coated total circuit group from 0.3 to 0.4 nmol/l, and in the Duraflo 2 group from 1.2 to 1.3 nmol/l. The prothrombin fragment 1+2 increase was significant in all groups (p < 0.05), but there were no significant intergroup differences (p = 0.54). There were no significant differences at the termination of the experiments among the four groups regarding complement activation as measured by C3 activation products and the terminal complement complex. In the present in vitro model of a heart-lung machine, none of the three specific setups with different coatings was superior with regard to all test parameters. The CBAS group generated the highest levels of prothrombin fragment 1+2 formation, but least complement activation. The increasing plasma heparin concentrations in the Duraflo 2 group indicated more unstable heparin bonding. The Avecor-coated total circuit group were superior to the Avecor-coated oxygenator group regarding plasma concentrations of MPO, but not compa

Antifibrinolytic Agents↗

Leucocyte filtration during cardiopulmonary bypass hardly changed leucocyte counts and did not influence myeloperoxidase, complement, cytokines or platelets.

In some patients, coronary artery bypass surgery induces postoperative organ dysfunction despite an apparently adequate revascularization and good haemodynamic performance. This complication may be caused by activation of the body's inflammatory systems on blood contact with large foreign surfaces in the extracorporeal circuit. Activated leucocytes may play an important role in organ damage, and it is conceivable that leucocyte removal by filtration may decrease the potential side-effects of cardiopulmonary bypass (CPB). The aim of the present study was to investigate possible effects of leucocyte filtration during the whole CPB period in elective coronary artery bypass surgery on biochemical and clinical parameters. Forty patients were randomized to extracorporeal circulation using a leucocyte-depleting filter (group L, n = 20) or to extracorporeal circulation with no leucocyte filter (group C, n = 20). In the leucocyte-depleted group, the mean total white blood cell counts increased from 6.3 (95% confidence interval, 5.5-7.0) x 10(9)/l to 7.0 (5.7-8.3) x 10(9)/l during extracorporeal circulation and in the control group from 6.3 (5.2-7.3) x 10(9)/l to 8.5 (7.2-9.8) x 10(9)/l. The intergroup difference was not statistically significant (p = 0.84). A substantial increase in concentrations of interleukin-6, myeloperoxidase and complement activation products were observed in both groups without statistically significant intergroup differences. It is concluded that the leucocyte-depletion filter did not cause a significant reduction of circulating white blood cells during CPB, and there were no significant differences between the groups with respect to the inflammatory markers studied.

Aged↗

[Bronchial resections].

In the period 1982-96, 18 bronchial resections were performed. Simple resection was carried out in eight patients, and in ten lung tissue was also removed; six upper lobes and three middle lobes were involved, and in one patient bilobectomy was necessary. The histologic diagnosis was carcinoid in 15 cases (83%), mucoepidermoid carcinoma in two, and in one case neurofibroma. Two patients had postoperative complications, but both recovered completely. All patients were followed up regularly by bronchoscopy. One patient had carcinoid with liver and bone metastases at the time of operation in 1989, but is still alive. Another died from metastases, the rest were in good condition at the most recent follow up. Bronchial resection is a safe procedure which should be preferred to standard pneumonectomy, in order to save as much lung tissue as possible. The frequency of bronchial resections for carcinoids (compared with standard pneumonectomy) was 60%.

Adolescent↗

Effects on complement, granulocytes and platelets of a leukocyte-depletion filter during in vitro extracorporeal circulation.

In an in vitro study, extracorporeal circuits equipped with either a leukocyte-depleting filter (n = 5) or a standard arterial-line filter (n = 5) were perfused for 120 minutes with fresh human whole blood. Leukocyte activation, leukocyte and platelet counts and complement activation were studied. Significant reduction of leukocyte and platelet counts and significant activation of leukocytes and of platelets were found in both groups, but without significant intergroup difference for any parameter after 120 minutes of perfusion. The leukocyte-depleting filters, however, were somewhat more effective in removing leukocytes during the initial 30 minutes of circulation.

Complement System Proteins↗

[Traumatic pneumopericardium with cardiac tamponade].

A 20 year old male motorist with multiple injuries, including bilateral lung laceration, developed cardiac tamponade 12 hours after injury. X-ray showed characteristic findings of pneumopericardium with air all around the cardiac silhouette, which was diminished in size. A chest tube was inserted intrapericardially through a subxiphoid incision. Blood pressure increased immediately, and central venous pressure became normal. Cardiac left ventricular stroke work increased by 86% to normal value. The drain was removed after three days. Another patient was a 15 year old male cyclist who had been overrun by a trailer. Left-sided emergency thoracotomy was performed during laparotomy for liver and vena cava injury, in the course of which procedures there was a sudden decrease in blood pressure with marked elevation of the central venous pressure. The pericardium was incised. Air hissed out, leading to normalisation of arterial and venous pressures. Both patients recovered. Pneumopericardium without symptoms may be treated by observation. Tension pneumopericardium is rare and is best treated by open drainage.

Accidents, Traffic↗