PubMed Health⌕ Search

Biomedical subjects

S T Moore

Publications and source records attributed to S T Moore.

At least 19 recordsLinked to original sources

Interaction of the body, head, and eyes during walking and turning.

Body, head, and eye movements were measured in five subjects during straight walking and while turning corners. The purpose was to determine how well the head and eyes followed the linear trajectory of the body in space and whether head orientation followed changes in the gravito-inertial acceleration vector (GIA). Head and body movements were measured with a video-based motion analysis system and horizontal, vertical, and torsional eye movements with video-oculography. During straight walking, there was lateral body motion at the stride frequency, which was at half the frequency of stepping. The GIA oscillated about the direction of heading, according to the acceleration and deceleration associated with heel strike and toe flexion, and the body yawed in concert with stepping. Despite the linear and rotatory motions of the head and body, the head pointed along the forward motion of the body during straight walking. The head pitch/roll component appeared to compensate for vertical and horizontal acceleration of the head rather than orienting to the tilt of the GIA or anticipating it. When turning corners, subjects walked on a 50-cm radius over two steps or on a 200-cm radius in five to seven steps. Maximum centripetal accelerations in sharp turns were ca.0.4 g, which tilted the GIA ca.21 degrees with regard to the heading. This was anticipated by a roll tilt of the head of up to 8 degrees. The eyes rolled 1-1.5 degrees and moved down into the direction of linear acceleration during the tilts of the GIA. Yaw head deviations moved smoothly through the turn, anticipating the shift in lateral body trajectory by as much as 25 degrees. The trunk did not anticipate the change in trajectory. Thus, in contrast to straight walking, the tilt axes of the head and the GIA tended to align during turns. Gaze was stable in space during the slow phases and jumped forward in saccades along the trajectory, leading it by larger angles when the angular velocity of turning was greater. The anticipatory roll head movements during turning are likely to be utilized to overcome inertial forces that would destabilize balance during turning. The data show that compensatory eye, head, and body movements stabilize gaze during straight walking, while orienting mechanisms direct the eyes, head, and body to tilts of the GIA in space during turning.

Acceleration↗

Ocular counterrolling induced by centrifugation during orbital space flight.

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural centripetal accelerations (Gy centrifugation) of 0.5 g and 1 g during rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear out or right-ear out, facing or back to motion. Binocular eye movements were measured in three dimensions using a video technique. On Earth, tangential centrifugation that produces 1 g of interaural linear acceleration combines with gravity to tilt the gravitoinertial acceleration (GIA) vector 45 degrees in the roll plane relative to the head vertical, generating a summed vector of 1.4 g. Before flight, this elicited mean ocular counterrolling (OCR) of 5.7 degrees. Due to the relative absence of gravity during flight, there was no linear acceleration along the dorsoventral axis of the head. As a result, during in-flight centrifugation, gravitoinertial acceleration was strictly aligned with the centripetal acceleration along the interaural axis. There was a small but significant decrease (mean 10%) in the magnitude of OCR in space (5.1 degrees). The magnitude of OCR during postflight 1 g centrifugation was not significantly different from preflight OCR (5.9 degrees). Findings were similar for 0.5 g centrifugation, but the OCR magnitude was approximately 60% of that induced by centrifugation at 1 g. OCR during pre- and postflight static tilt was not significantly different and was always less than OCR elicited by centrifugation of Earth for an equivalent interaural linear acceleration. In contrast, there was no difference between the OCR generated by in-flight centrifugation and by static tilt on Earth at equivalent interaural linear accelerations. These data support the following conclusions: (1) OCR is generated predominantly in response to interaural linear acceleration; (2) the increased OCR during centrifugation on Earth is a response to the head dorsoventral 1 g linear acceleration component, which was absent in microgravity. The dorsoventral linear acceleration could have activated either the otoliths or body-tilt receptors that responded to the larger GIA magnitude (1.4 g), to generate the increased OCR during centrifugation on Earth. A striking finding was that magnitude of OCR was maintained throughout and after flight. This is in contrast to most previous postflight OCR studies, which have generally registered decreases in OCR. We postulate that intermittent exposure to artificial gravity, in the form of the centripetal acceleration experienced during centrifugation, acted as a countermeasure to deconditioning of this otolith-ocular orienting reflex during the 16-day mission.

Acceleration↗

Perception of tilt (somatogravic illusion) in response to sustained linear acceleration during space flight.

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural and head vertical (dorsoventral) linear accelerations of 0.5 g and 1 g during constant velocity rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear-out or right-ear-out (Gy centrifugation), or lay supine along the centrifuge arm with their head off-axis (Gz centrifugation). Pre-flight centrifugation, producing linear accelerations of 0.5 g and 1 g along the Gy (interaural) axis, induced illusions of roll-tilt of 20 degrees and 34 degrees for gravito-inertial acceleration (GIA) vector tilts of 27 degrees and 45 degrees , respectively. Pre-flight 0.5 g and 1 g Gz (head dorsoventral) centrifugation generated perceptions of backward pitch of 5 degrees and 15 degrees , respectively. In the absence of gravity during space flight, the same centrifugation generated a GIA that was equivalent to the centripetal acceleration and aligned with the Gy or Gz axes. Perception of tilt was underestimated relative to this new GIA orientation during early in-flight Gy centrifugation, but was close to the GIA after 16 days in orbit, when subjects reported that they felt as if they were 'lying on side'. During the course of the mission, inflight roll-tilt perception during Gy centrifugation increased from 45 degrees to 83 degrees at 1 g and from 42 degrees to 48 degrees at 0.5 g. Subjects felt 'upside-down' during in-flight Gz centrifugation from the first in-flight test session, which reflected the new GIA orientation along the head dorsoventral axis. The different levels of in-flight tilt perception during 0.5 g and 1 g Gy centrifugation suggests that other non-vestibular inputs, including an internal estimate of the body vertical and somatic sensation, were utilized in generating tilt perception. Interpretation of data by a weighted sum of body vertical and somatic vectors, with an estimate of the GIA from the otoliths, suggests that perception weights the sense of the body vertical more heavily early in-flight, that this weighting falls during adaptation to microgravity, and that the decreased reliance on the body vertical persists early post-flight, generating an exaggerated sense of tilt. Since graviceptors respond to linear acceleration and not to head tilt in orbit, it has been proposed that adaptation to weightlessness entails reinterpretation of otolith activity, causing tilt to be perceived as translation. Since linear acceleration during in-flight centrifugation was always perceived as tilt, not translation, the findings do not support this hypothesis.

Acceleration↗

Effects of walking velocity on vertical head and body movements during locomotion.

Trunk and head movements were characterized over a wide range of walking speeds to determine the relationship between stride length, stepping frequency, vertical head translation, pitch rotation of the head, and pitch trunk rotation as a function of gait velocity. Subjects (26-44 years old) walked on a linear treadmill at velocities of 0.6-2.2 m/s. The head and trunk were modeled as rigid bodies, and rotation and translation were determined using a video-based motion analysis system. At walking speeds up to 1.2 m/s there was little head pitch movement in space, and the head pitch relative to the trunk was compensatory for trunk pitch. As walking velocity increased, trunk pitch remained approximately invariant, but a significant head translation developed. This head translation induced compensatory head pitch in space, which tended to point the head at a fixed point in front of the subject that remained approximately invariant with regard to walking speed. The predominant frequency of head translation and rotation was restricted to a narrow range from 1.4 Hz at 0.6 m/s to 2.5 Hz at 2.2 m/s. Within the range of 0.8-1.8 m/s, subjects tended to increase their stride length rather than step frequency to walk faster, maintaining the predominant frequency of head movement at close to 2.0 Hz. At walking speeds above 1.2 m/s, head pitch in space was highly coherent with, and compensatory for, vertical head translation. In the range 1.2-1.8 m/s, the power spectrum of vertical head translation was the most highly tuned, and the relationship between walking speed and head and trunk movements was the most linear. We define this as an optimal range of walking velocity with regard to head-trunk coordination. The coordination of head and trunk movement was less coherent at walking velocities below 1.2 m/s and above 1.8 m/s. These results suggest that two mechanisms are utilized to maintain a stable head fixation distance over the optimal range of walking velocities. The relative contribution of each mechanism to head orientation depends on the frequency of head movement and consequently on walking velocity. From consideration of the frequency characteristics of the compensatory head pitch, we infer that compensatory head pitch movements may be produced predominantly by the angular vestibulocollic reflex (aVCR) at low walking speeds and by the linear vestibulocollic reflex (1VCR) at the higher speeds.

Abdomen↗

Effect of viewing distance on the generation of vertical eye movements during locomotion.

Vertical head and eye coordination was studied as a function of viewing distance during locomotion. Vertical head translation and pitch movements were measured using a video motion analysis system (Optotrak 3020). Vertical eye movements were recorded using a video-based pupil tracker (Iscan). Subjects (five) walked on a linear treadmill at a speed of 1.67 m/s (6 km/h) while viewing a target screen placed at distances ranging from 0.25 to 2.0 m at 0. 25-m intervals. The predominant frequency of vertical head movement was 2 Hz. In accordance with previous studies, there was a small head pitch rotation, which was compensatory for vertical head translation. The magnitude of the vertical head movements and the phase relationship between head translation and pitch were little affected by viewing distance, and tended to orient the naso-occipital axis of the head at a point approximately 1 m in front of the subject (the head fixation distance or HFD). In contrast, eye velocity was significantly affected by viewing distance. When viewing a far (2-m) target, vertical eye velocity was 180 degrees out of phase with head pitch velocity, with a gain of 0. 8. This indicated that the angular vestibulo-ocular reflex (aVOR) was generating the eye movement response. The major finding was that, at a close viewing distance (0.25 m), eye velocity was in phase with head pitch and compensatory for vertical head translation, suggesting that activation of the linear vestibulo-ocular reflex (lVOR) was contributing to the eye movement response. There was also a threefold increase in the magnitude of eye velocity when viewing near targets, which was consistent with the goal of maintaining gaze on target. The required vertical lVOR sensitivity to cancel an unmodified aVOR response and generate the observed eye velocity magnitude for near targets was almost 3 times that previously measured. Supplementary experiments were performed utilizing body-fixed active head pitch rotations at 1 and 2 Hz while viewing a head-fixed target. Results indicated that the interaction of smooth pursuit and the aVOR during visual suppression could modify both the gain and phase characteristics of the aVOR at frequencies encountered during locomotion. When walking, targets located closer than the HFD (1.0 m) would appear to move in the same direction as the head pitch, resulting in suppression of the aVOR. The results of the head-fixed target experiment suggest that phase modification of the aVOR during visual suppression could play a role in generating eye movements consistent with the goal of maintaining gaze on targets closer than the HFD, which would augment the lVOR response.

Adolescent↗

Robust pupil center detection using a curvature algorithm.

Determining the pupil center is fundamental for calculating eye orientation in video-based systems. Existing techniques are error prone and not robust because eyelids, eyelashes, corneal reflections or shadows in many instances occlude the pupil. We have developed a new algorithm which utilizes curvature characteristics of the pupil boundary to eliminate these artifacts. Pupil center is computed based solely on points related to the pupil boundary. For each boundary point, a curvature value is computed. Occlusion of the boundary induces characteristic peaks in the curvature function. Curvature values for normal pupil sizes were determined and a threshold was found which together with heuristics discriminated normal from abnormal curvature. Remaining boundary points were fit with an ellipse using a least squares error criterion. The center of the ellipse is an estimate of the pupil center. This technique is robust and accurately estimates pupil center with less than 40% of the pupil boundary points visible.

Algorithms↗

How consumers evaluate health care quality: Part I.

Information is a critical factor in marketing health care services. Consumers evaluate information according to its source. This report is the first of a three-part series examining the way in which Americans evaluate the quality of consumer information as they make decisions on health care products and services. This report provides an overview of the study. The next two installations will focus, respectively, on health plans, hospital and doctors.

Communication↗

How consumers evaluate health care quality: Part III.

This article is the third and final article in a series which examines the way in which consumers assess information regarding the quality of health care services. The previous article focused on consumers' perceptions of health care plans and health insurance companies. This article examines the views of health care consumers regarding hospitals and doctors.

Adult↗

How consumers evaluate health care quality: Part II.

This article is the second in a series which examines the way in which consumers assess information regarding the quality of health care services. In the previous article it was demonstrated that, in the view of health care consumers, three major perceptions held by health care consumers, are: (1) substantial differences in quality exist among health care providers, (2) little information is available that allows for the comparison of health care providers on issues related to quality, and (3) when such information is available it is found to be useful and often serves as the basis for decision regarding the choice of health care providers. We further discussed the short coming of marketing strategies based on complex quality indicators and the difficulties of image advertising in an age of institutional mistrust. The reader is reminded that these findings relate to the subjective assessments of consumers, not to objective facts concerning health care delivery.

Advertising↗

Social welfare in a managerial society.

Managerialism is a dominant ideology in the institution of social welfare and the profession of social work. Managerialism includes the tools and traditions of modern management. It is also a way of viewing the social world. Managerialism is a useful but limited ideology in social work and social welfare. The benefits of this perspective include the ordering and sanctioning of professional social workers and the application of sophisticated management tools in the institution of social welfare. Managerialism threatens the historic mission and identity of social work and social welfare. The field is challenged to find an institutional niche for those aspects that are outside the mainstream of the commercial culture.

Community Health Services↗

A geometric basis for measurement of three-dimensional eye position using image processing.

Polar cross correlation is commonly used for determination of ocular torsion from video images, but breaks down at eccentric positions if the spherical geometry of the eye is not considered. We have extended this method to allow three-dimensional eye position measurement over a range of +/- 20 deg by determining the correct projection of the eye onto the image plane of the camera. We also determine the orientation of the camera with respect to the eye, allowing eye position to be represented in appropriate head-fixed coordinates. These algorithms have been validated using both in vitro and in vivo measures of eye position.

Algorithms↗

The human ocular torsion position response during yaw angular acceleration.

Recent results by Wearne [(1993) Ph.D. thesis] using the scleral search-coil method of measuring eye position indicate that changes in ocular torsion position (OTP) occur during yaw angular acceleration about an earth vertical axis. The present set of experiments, using an image processing method of eye movement measurement free from the possible confound of search coil slippage, demonstrates the generality and repeatability of this phenomenon and examines its possible causes. The change in torsion position is not a linear vestibulo-ocular reflex (LVOR) response to interaural linear acceleration stimulation of the otoliths, but rather the effect is dependent on the characteristics of the angular acceleration stimulus, commencing at the onset and decaying at the offset of the angular acceleration. In the experiments reported here, the magnitude of the angular acceleration stimulus was varied and the torsion position response showed corresponding variations. We consider that the change in torsion position observed during angular acceleration is most likely to be due to activity of the semicircular canals.

Acceleration↗

A theoretical analysis of three-dimensional eye position measurement using polar cross-correlation.

Polar cross-correlation is a commonly used technique for determination of torsional eye position from video images. At eccentric eye positions, the projection of the sampling window onto the image plane of the camera is translated and deformed due to the spherical shape of the eyeball. In this paper, we extend the polar cross-correlation technique by developing the formulas required to determine the correct location and shape of the sampling window at all eye positions. These formulas also allow the representation of three-dimensional eye position in Fick-angles, which are commonly used in oculomotor research. A numerical simulation shows the size of the errors in ocular torsion if the spherical geometry of the eye is not considered. Other effects which can affect the accuracy of video-based eye position measurements are also discussed.

Algorithms↗

Maximizing satisfaction and managing dissatisfaction in mental health and human services: a model for administrative practice.

The production satisfaction is central to the delivery of mental health and human service. The most critical factor in service delivery is providing quality care. However, the ways in which services are delivered impacts the perception of quality. This paper provides a model for maximizing satisfaction among client and other important public of mental health and human service organizations.

Consumer Behavior↗

VTM--an image-processing system for measuring ocular torsion.

This paper reports a new, fast, accurate realization of an image-processing method of measuring ocular torsion (rotation of the eyeball around the visual axis) called Video Torsion Measurement (VTM). The method is to cross-correlate the two grey-level distributions of an arc of the iris from two separate images using a fast image processor card interfaced to an IBM-AT compatible computer. The card (Matrox MVP-AT) is supplied with a library of low-level functions for controlling the hardware operations of the board and the VTM system software, which is written in the C programming language, incorporates these low-level functions to interface with the MVP-AT board as well as carrying out the data-acquisition and processing algorithms. These programs: acquire an image of an iris illuminated by a single infrared (IR) light source; threshold this image in order to identify the pupil; calculate the pupil area and locate the centre of the pupil using a centre-of-gravity algorithm; record the grey-level distribution along an arc 256 pixels long at a selected radius from the pupil centre; carry out an FFT on this (interpolated) grey level distribution; store the parameters of this reference FFT and cross-correlate the comparable iral grey-level distribution from other test images of the same eye in order to determine the amount of torsional rotation of the test images relative to the reference image. This system is interactive and is designed for operation in a clinical testing situation with a minimum of operator intervention. The VTM system has a resolution of the order of 0.1 deg depending on the arc radius used and it has been validated in two ways: by using it to measure known torsional rotations of an artificial iris-like pattern and also by direct simultaneous comparison of measures on the same human iris images from VTM and those from the standard 35 mm photographic procedure of measuring torsion.

Eye Movements↗

Social density, stressors, and depression: gender differences among the black elderly.

This research examined gender differences with regard to the effects of social density and stressors upon depressive symptomatology among 600 Black elderly community residents (aged 55-85 years) of Nashville, Tennessee. The sample had more females than males and fewer married individuals. Approximately half of the males and females lived alone. Regression analyses show that poor ego and chronic medical problems were the common predictors of depression among both the males and females. Gender differences were found with regard to life events in that females tended to become more depressed as the number of events increased and as level of contact with relatives and friends decreased. Further, females with lower levels of social attachment, guidance, and reliability were more depressed. None of these social support dimensions related to depression among the males. These relationships tended to be stronger for those living alone than for those living with others.

Black or African American↗