PubMed Health⌕ Search

Biomedical subjects

S T Yount

Publications and source records attributed to S T Yount.

3 recordsLinked to original sources

Effect of aluminized covers on body temperature in patients having abdominal surgery.

An unintended fall in body temperature is commonly associated with surgery. One promising strategy to help conserve body heat is use of covers made of aluminum-coated plastic. We compared the effect of three combinations of the covers (head cover, body covers, both) and a control condition on tympanic temperature in 60 adults having major abdominal surgery under general anesthesia. The covers were applied from the time of transport to the operating room until exit from the postanesthesia care unit (PACU). Tympanic temperature was measured with an infrared thermometer. Between transport and PACU entry, the four groups had mean temperature decreases ranging from 1.6 degrees to 2.3 degrees F (0.9 degree to 1.3 degrees C). After controlling for background variables affecting body temperature, adjusted PACU entry temperature was higher in the two groups with aluminized body covers. Regression analysis showed that use of the body covers accounted for 7% of the temperature variance at PACU entry and predicted a 0.9 degree F (0.5 degree C) higher temperature at that time. These findings indicate that aluminized body covers help to reduce heat loss in patients having major abdominal surgery.

Abdomen↗

Comparison of tympanic and oral temperatures in surgical patients.

The purpose of this study was to compare tympanic and oral temperatures at four times during the perioperative period in 60 adults having major abdominal surgery. Tympanic temperature was measured with an infrared thermometer and oral temperature with a predictive thermistor thermometer. Measurements at the two sites were similar in pattern and moderately well correlated. Tympanic temperature was somewhat more sensitive to the effects of an intervention influencing body temperature. The tympanic-oral temperature offset was relatively stable over time, with tympanic readings having a smaller range of values at each measurement. Tympanic temperature measurement variation was fairly small, with 92% of readings reproducible within 0.5 degree F (0.3 degree C); comparable oral data were not available. The findings suggest that the tympanic site offers some advantage, but that either tympanic or oral readings would be satisfactory for routine intermittent monitoring of body temperature during the perioperative period.

Adult↗