PubMed Health⌕ Search

Biomedical subjects

S Tateshima

Publications and source records attributed to S Tateshima.

6 recordsLinked to original sources

Bioabsorbable polymeric material coils for embolization of intracranial aneurysms: a preliminary experimental study.

OBJECT: A new embolic agent, bioabsorbable polymeric material (BPM), was incorporated into Guglielmi detachable coils (GDCs) to improve long-term anatomical results in the endovascular treatment of intracranial aneurysms. The authors investigated whether BPM-mounted GDCs (BPM/GDCs) accelerated the histopathological transformation of unorganized blood clot into fibrous connective tissue in experimental aneurysms created in swine. METHODS: Twenty-four experimental aneurysms were created in 12 swine. In each animal, one aneurysm was embolized using BPM/GDCs and the other aneurysm was embolized using standard GDCs. Comparative angiographic and histopathological data were analyzed at 2 weeks and 3 months postembolization. At 14 days postembolization, angiograms revealed evidence of neck neointima in six of eight aneurysms treated with BPM/GDCs compared with zero of eight aneurysms treated with standard GDCs (p < 0.05). At 3 months postembolization, angiograms demonstrated that four of four aneurysms treated with BPM/GDC were smaller and had neck neointima compared with zero of four aneurysms treated with standard GDCs (p = 0.05). At 14 days, histological analysis of aneurysm healing favored BPM/GDC treatment (all p < 0.05): the grade of cellular reaction around the coils was 3 +/- 0.9 (mean +/- standard deviation) for aneurysms treated using BPM/GDCs compared with 1.6 +/- 0.7 for aneurysms treated using GDCs alone; the percentage of unorganized thrombus was 16 +/- 12% compared with 37 +/- 15%, and the neck neointima thickness was 0.65 +/- 0.26 mm compared with 0.24 +/- 0.21 mm, respectively. At 3 months postembolization, only neck neointima thickness was significantly different (p < 0.05): 0.73 +/- 0.37 mm in aneurysms filled with BPM/GDCs compared with 0.16 +/- 0.14 mm in aneurysms filled with standard GDCs. CONCLUSIONS: In experimental aneurysms in swine, BPM/GDCs accelerated aneurysm fibrosis and intensified neck neointima formation without causing parent artery stenosis or thrombosis. The use of BPM/GDCs may improve long-term anatomical outcomes by decreasing aneurysm recanalization due to stronger in situ anchoring of coils by organized fibrous tissue. The retraction of this scar tissue may also decrease the size of aneurysms and clinical manifestations of mass effect observed in large or giant aneurysms.

Absorbable Implants↗

Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a mold.

OBJECT: To obtain precise flow profiles in patients' aneurysms, the authors developed a new in vitro study method featuring an aneurysm model manufactured using three-dimensional computerized tomography (3D CT) angiography. METHODS: A clear acrylic basilar artery (BA) tip aneurysm model manufactured from a patient's 3D CT angiogram was used to analyze flow modifications during one cardiac cycle. Stereolithography was utilized to create the aneurysm model. Three-dimensional flow profiles within the aneurysm model were obtained from velocity measurements by using laser Doppler velocimetry. The aneurysm inflow/outflow zones changed dynamically in their location, size of their cross-sectional area, and also in their shapes over one cardiac cycle. The flow velocity at the inflow zone was 16.8 to 81.9% of the highest axial velocity in the BA with a pulsatility index (PI) of 1.1. The flow velocity at the outflow zone was 16.8 to 34.3% of the highest axial velocity of the BA, with a PI of 0.68. The shear stress along the walls of the aneurysm was calculated from the fluid velocity measured at a distance of 0.5 mm from the wall. The highest value of shear stress was observed at the bleb of the aneurysm. CONCLUSIONS: This clear acrylic model of a BA tip aneurysm manufactured using a CT angiogram allowed qualitative and quantitative analysis of its flow during a cardiac cycle. Accumulated knowledge from this type of study may reveal pertinent information about aneurysmal flow dynamics that will help practitioners understand the relationship among anatomy, flow dynamics, and the natural history of aneurysms.

Acrylic Resins↗

Rapidly enlarging dermoid cyst over the anterior fontanel: a case report and review of the literature.

A case report of a rapidly enlarging dermoid cyst over the anterior fontanel is presented. Our presentation demonstrates the course of rapid enlargement of the tumor with radiological images, which were examined at birth and during the process of the tumor enlargement. The literature is reviewed with respect to the nature of this tumor, especially to the relationship of tumor enlargement.

Cranial Sutures↗

Endovascular treatment of experimental aneurysms by use of a combination of liquid embolic agents and protective devices.

BACKGROUND AND PURPOSE: The use of liquid embolic agents for embolization of cerebral aneurysms has been reported in the neurosurgical literature. The most important limitation of this technique is the relatively poor control of migration of the liquid embolic agent into the parent artery. We performed an experimental aneurysm study using a liquid embolic agent and different protective devices to evaluate the safety and technical feasibility of this endovascular technique. METHODS: Forty lateral aneurysms were surgically constructed on 20 common carotid arteries of swine. Onyx alone was used to obliterate eight aneurysms. Onyx was also used in combination with microcoils (n = 11), microstents (n = 6), balloons inflated proximally to the neck of the aneurysm (n = 6), and across the neck of the aneurysm (n = 7). One control aneurysm was embolized with Guglielmi detachable coils (GDCs) alone. RESULTS: The use of a microballoon across the neck of the aneurysm, a microstent deployed across the neck of the aneurysm, or the deposit of GDCs into the aneurysm allowed faster and more complete filling of the aneurysm with Onyx. However, these protection devices did not totally preclude intractable migration of Onyx into the parent artery (migration rate, 9-33%). CONCLUSION: Although complete occlusion of experimental aneurysms with Onyx is feasible using protective devices, migration of the liquid embolic agent into the parent artery or intracranially remains a difficult challenge. Further experimental studies need to be performed to master this technique and to select those aneurysms that can be safely treated in clinical practice.

Animals↗

Endovascular treatment of basilar tip aneurysms using Guglielmi detachable coils: anatomic and clinical outcomes in 73 patients from a single institution.

OBJECTIVE: Seventy-three consecutive patients with 75 basilar tip aneurysms were treated with Guglielmi detachable coil (GDC) technology. Their anatomic and clinical outcomes are discussed. METHODS: Seventy-five basilar tip aneurysms were treated with the GDC system at the University of California, Los Angeles Medical Center from 1990 to 1999. The average age of the population was 48.3 years (range, 28-82 yr). Forty-two patients (57.5%) presented with acute subarachnoid hemorrhage, 8 patients (10.9%) had unruptured aneurysms with mass effect, and 23 patients (31.5%) had incidental aneurysms. Thirty-one aneurysms (41.3%) were small with a small neck, 18 (24%) were small with a wide neck, 16 (21.3%) were large, and 10 (13.3%) were giant aneurysms. RESULTS: Immediate anatomic outcomes demonstrated complete or near-complete occlusion in 64 aneurysms (85.3%) and incomplete occlusion in 7 aneurysms (9.3%). Four aneurysms (5.3%) could not be embolized because of anatomic difficulties. Of the 69 patients treated with GDCs, 63 patients (91.3%) remained neurologically intact or unchanged from their initial clinical status. Procedure-related morbidity and mortality were 4.1% and 1.4%, respectively. Long-term follow-up angiograms were obtained in 41 patients with 42 aneurysms. Thirty aneurysms (71.4%) demonstrated complete or near-complete occlusion. One incompletely embolized giant aneurysm ruptured during the follow-up period. CONCLUSION: In contrast to surgical clipping of basilar tip aneurysms, the main technical challenge of the Guglielmi detachable coiling procedure depends on the shape of the aneurysm, not its location. The results of this study indicate that endovascular GDC technology is an appropriate therapeutic alternative in ruptured or unruptured basilar tip aneurysms regardless of patient age, clinical presentation, clinical status, or timing of treatment.

Adult↗

[Detection and genotype analysis of GB virus C/hepatitis G virus (GBV-C/HGV) in the sera of Japanese patients with hemophilia A].

The recently discovered GB virus C/hepatitis G virus (GBV-C/HGV) has been shown to be scarcely associated with hepatitis, though its possible pathogenesis remains unknown. In previous report, we designed primers for semi-nested reverse transcription-polymerase chain reaction (RT-PCR) to detect 5'-noncoding region of GBV-C/HGV, and screened the sera from 45 patients with liver diseases or on hemodialysis. In this study, we studied the prevalence of GBV-C/HGV infection in the sera from 35 patients with hemophilia A by this RT-PCR method, and also performed sequence analysis for all isolates including those from the non-hemophilic patients previously reported. GBV-C/HGV was detected in 8.57% (3/35) of the hemophilic patients. The isolates from hemophilic patients had several common mutations, and these mutations were also common in the "West African" genotype isolates represented by the prototype GBV-C. However, sequences in the isolates from other positive patients with liver diseases or on hemodialysis were quite different from those in the isolates from hemophilic patients, and those in the "European/American" genotype isolates represented by the prototype HGV. These sequences were consistent with "Asian" genotype. Simple restriction fragment length polymorphism (RFLP) analysis using the restriction enzyme HhaI successfully discriminated these genotypes. In the hemophilic patients, GBV-C/HGV might have been transmitted by transfusions of the imported plasma-derived clotting factor concentrates. Thus the difference in GBV-C/HGV genotype between the hemophilic patients and the others is suggested to be related to transmission route.

Adolescent↗