PubMed Health⌕ Search

Biomedical subjects

S Toksvig-Larsen

Publications and source records attributed to S Toksvig-Larsen.

At least 37 records · Page 2Linked to original sources

Changes in osseous correction after proximal tibial osteotomy: radiostereometry of closed- and open-wedge osteotomy in 33 patients.

33 patients (22 men), median age 54 (40-68) years, with medial gonarthrosis grades 1-3, were treated by closed-wedge osteotomy (high tibial osteotomy = HTO, n 16) or open-wedge osteotomy by hemicallotasis (hemicallotasis osteotomy = HCO, n 19). 2 patients were operated on bilaterally. The patients were studied by RSA (radiostereometric analysis) for measuring 3-D changes in the correction achieved. In the HTO group the RSA measurements were obtained at the time of plaster removal, 1 month later and 1 year after surgery. In the HCO group, the RSA measurements were performed at the time of removal of the external fixator, 1 month later and 1 year after surgery. After removal of the fixation, HTO was associated with increased medial/lateral and distal translation of the proximal segment, compared to HCO. In addition, the tibial plateau rotated more around the longitudinal axis of the tibia after HTO.

Adult↗

Rearrangement of the neoplasia-associated gene HMGIC in synovia from patients with osteoarthritis.

The occurrence of clonal chromosome aberrations in short-term cultures from synovia, osteophytes, and cartilage from patients with osteoarthritis (OA) was recently reported. Among these aberrations, a recurrent involvement of chromosome bands 12q13-15 in structural rearrangements was detected in both synovia and osteophytes. Chromosomal abnormalities of 12q13-15 are frequent among malignant and benign mesenchymal tumors, and it was recently demonstrated that the molecular target in these neoplasms is the HMGIC gene. In this study, we show by fluorescence in situ hybridization that HMGIC was disrupted by rearrangements of 12q15 in synovia from two patients with OA. The finding of HMGIC rearrangement in a lesion that is not traditionally regarded as neoplastic not only widens the spectrum of disorders that may be associated with altered function of this gene, but also provides further support for the notion that genetically rearranged cell populations are part of the OA process.

Aged↗

Polyclonal expansion of cells with trisomy 7 in synovia from patients with osteoarthritis.

Trisomy 7 as the single chromosome aberration has been found in a variety of neoplasms and in normal tissue in the proximity of tumors, as well as in non-neoplastic lesions. Recently, we described a nonrandom pattern of chromosome aberrations, in particular, a gain of chromosome 7, in synovia, cartilage, and osteophytes from patients with osteoarthritis. To study the clonal origin of trisomy 7 in osteoarthritis, multiple synovial samples were collected from five women, all of whom were informative heterozygotes with regard to the X-linked human androgen receptor gene (AR). From each case, three to four independent cell cultures were initiated. Trisomic cell populations were subcloned from the individual cultures, and it was established whether or not the same allele of AR was inactivated in trisomic cells from different parts of the same joint. The finding of a polyclonal X-inactivation pattern in two of the cases provides strong evidence that gain of an extra copy of chromosome 7 occurs independently in multiple cells.

Aged↗

Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy: a matched radiostereometric study.

To assess migration of the tibial component we used roentgen stereophotogrammetric analysis in 40 patients who had had a total knee arthroplasty after failure of a closing wedge osteotomy and compared them with 40 matched patients after primary total knee arthroplasty. We found no difference in migration over time or in the tendency for continuous migration between the two groups. There were no differences in alignment or position of the knee prosthesis or in the clinical outcome. Our findings show that revision of a failed high tibial osteotomy to a total knee arthroplasty is effective.

Aged↗

A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins. An in vivo study in sheep.

Three types of surfaces for external fixation pins were compared. One hundred and eight stainless-steel tapered 5/6-millimeter pins were divided into three groups: thirty-six pins remained uncoated (Group A), thirty-six were plasma-sprayed with hydroxyapatite (Group B), and thirty-six were plasma-sprayed with titanium (Group C). The pins were implanted in the left tibia of eighteen sheep, with each sheep receiving six pins from the same group. A unilateral fixator then was assembled on the pins. The medial aspect of the mid-part of the tibial diaphysis was exposed, and a five-millimeter-long cylinder of bone was removed so that load would be borne by the bone-pin interfaces. Six weeks after the procedure, radiographs demonstrated rarefaction of twenty-nine pin tracks in Group A, fifteen in Group B, and thirty in Group C (p = 0.021 for Group A compared with Group B and p = 0.016 for Group B compared with Group C). The mean final insertion torque (and standard deviation) was 4360+/-1050 newton-millimeters in Group A, 3420+/-676 newton-millimeters in Group B, and 3740+/-643 newton-millimeters in Group C. With the numbers available, no significant differences could be detected among these values. The mean extraction torque was 253+/-175 newton-millimeters in Group A, 3360+/-1260 newton-millimeters in Group B, and 1720+/-1030 newton-millimeters in Group C (p = 0.002 for Group A compared with Group B, p = 0.017 for Group A compared with Group C, and p = 0.03 for Group B compared with Group C). The extraction torque was significantly lower than the corresponding insertion torque in both Group A (p < 0.001) and Group C (p = 0.003); no significant difference could be found, with the numbers available, in Group B (hydroxyapatite-coated pins). At sixty times magnification, direct contact was seen along a mean of 16+/-9 per cent of the bone-pin interface in Group A, 30+/-12 per cent of the interface in Group B, and 28+/-15 per cent of the interface in Group C (p = 0.042 for Group A compared with Group C). However, at 10,000 times magnification, direct bone-pin contact was found only in Group B.

Animals↗

Open wedge tibial osteotomy by callus distraction in gonarthrosis. Operative technique and early results in 36 patients.

Proximal tibial osteotomy is indicated in cases of medial gonarthrosis with varus deformity in the active, younger patient. We report our experience of the hemicallotasis technique in 36 patients and the early clinical results after a median follow-up of 14 (11-16) months. The median patient age was 54 (33-64) years. The median hip-knee-ankle (HKA) angle was 172 (161-179) degrees preoperatively, 184 (178-187) degrees after completed correction and 183 (175-190) degrees at follow-up. The median fixation time was 88 (61-146) days. Complications were minor. Superficial pin-site inflammation/infections occurred in one fifth of the pins. The HSS score increased from a median 71 preoperatively to 94 at follow-up, the Lysholm score from 56 to 91 and the Tegner activity score from 6 to 10. The Nottingham Health Profile showed significant improvements as regards pain and physical mobility.

Adult↗

Early inducible displacement of tibial components in total knee prostheses inserted with and without cement: a randomized study with roentgen stereophotogrammetric analysis.

The fixation of tibial components randomized to insertion with or without cement in twenty-six knees was examined for inducible displacement at six weeks and one year postoperatively with use of roentgen stereophotogrammetric analysis. Furthermore, migration was studied during the first two postoperative years. Inducible displacement was found in all knees at both the six-week and the one-year follow-up examination, but no differences were detected with respect to the type of fixation (p > 0.05). All tibial components migrated for as long as one year postoperatively, after which most stabilized. No difference was found between the groups with respect to migration during the first two years postoperatively (p > 0.05), with the exception of subsidence of the component, which was found to be 0.0+/-0.1 millimeter (mean and standard error of the mean) for the components inserted with cement and 0.5+/-0.1 millimeter for the components inserted without cement (p < 0.01). Migration after one year was the same for both groups. We found a relationship between inducible displacement at six weeks and at one year as well as one between inducible displacement and migration at one year. To our knowledge, the present study is the first in which the micromotion of an interference-fit prosthesis was found to be similar to that of a device inserted with cement. The results of the present study emphasize the importance of the initial prosthetic fixation.

Aged↗

Enhanced fixation with hydroxyapatite coated pins.

Three groups of seven patients had external fixation of middiaphyseal tibial fractures using uncoated pins, uncoated bicylindrical pins, and hydroxyapatite coated bicylindrical pins, respectively. All fractures were fixed with six pins, and all fractures united. Median pin insertion torque was 0.6, 1.2, and 1.3 Nm in the three groups, respectively. Median extraction torque was 0.1, 0.1, and 2.1 Nm, respectively. Both types of stainless steel pins showed a lower extraction torque than insertion torque in all cases, whereas the mean extraction torque in the hydroxyapatite coated pins was unchanged. Seven of the 14 patients receiving uncoated pins had pin tract infection, compared with none of the patients receiving hydroxyapatite coated pins. Hydroxyapatite coating of external fixation pins increases stability and thereby reduces the risk for pin tract infection and mechanical failure of fracture fixation.

Adolescent↗

Prevention of deep vein thrombosis in knee arthroplasty. Preliminary results from a randomized controlled study of low molecular weight heparin vs foot pump compression.

BACKGROUND: We evaluated in a randomized controlled study the possibility to use foot pump mechanical compression compared to routine LMWH as prophylaxis against deep vein thrombosis during knee arthroplasty. METHODS: Forty patients were included in this preliminary report. Eleven patients withdrew, usually during the early phase of the study. RESULTS: Among the 29 patients completing a venography, 27% in the compression group and none in the LMWH group had a DVT. This difference was statistically significant (p<0.05). One further patient in the compression group died from pulmonary embolism 17 days postoperatively. CONCLUSIONS: With the present study protocol, mechanical foot pump compression failed to be as efficient as LMWH prophylaxis.

Aged↗

Clonal chromosome aberrations are present in vivo in synovia and osteophytes from patients with osteoarthritis.

We have previously reported recurrent clonal chromosomal aberrations in synovia, osteophytes and articular cartilage from patients with osteoarthritis (OA). In particular, gain of chromosomes 5 and 7 was found to be strongly associated with OA. In order to exclude the possibility of in vitro artefacts, we studied three to four parallel, independent cultures from ten samples of synovia and three samples of osteophytes from ten women with primary OA. In all, 40 cultures were cytogenetically analysed, 39 of which had clonal chromosomal aberrations. The most common aberrations were +7 and +5 which were found in 38 and 12 cultures, respectively. There were striking karyotype similarities among the parallel cultures from each case. Out of a total of 83 clones, only 11 were unique for one culture, 7 from synovia and 4 from osteophytes. The genetic homogeneity among different cultures from the same patients excludes the possibility of in vitro artefacts and indicates a widespread distribution of the cytogenetically aberrant clones in vivo.

Aged↗

Roentgen stereophotogrammetric analysis using computer-based image-analysis.

The two-dimensional position of markers in radiographs for Roentgen Stereophotogrammetric Analysis (RSA) is usually determined using a measuring table. The purpose of this study was to evaluate the reproducibility and the accuracy of a new RSA system using digitized radiographs and image-processing algorithms to determine the marker position in the radiographs. Four double-RSA examinations of a phantom and 18 RSA examinations from six patients included in different RSA-studies of knee prostheses were used to test the reproducibility and the accuracy of the system. The radiographs were scanned at 600 dpi resolution and 256 gray levels. The center of each of the tantalum-markers in the radiographs was calculated by the computer program from the contour of the marker with the use of an edge-detection software algorithm after the marker was identified on a PC monitor. The study showed that computer-based image analysis can be used in RSA-examinations. The advantages of using image-processing software in RSA are that the marker positions are determined in an objective manner, and that there is no need for a systematic manual identification of all the markers on the radiograph before the actual measurement.

Arthrography↗

Hydroxyapatite coating of threaded pins enhances fixation.

We measured the insertion and extraction torque forces in a randomised study of 76 external fixation screws in 19 patients treated by hemicallotasis for osteoarthritis of the medial side of the knee. The patients were randomised to have either standard tapered screws (Orthofix 6/5 mm) or the same screws with hydroxyapatite (HA) coating. One patient had two standard and two HA-coated screws. All patients had an anterior external fixator (Orthofix T-garche), with two screws in the proximal tibial metaphysis parallel to and about 2 cm below the joint surface and two in the tibial diaphysis. The mean torque forces for insertion of the standard screws were 260 Ncm for the proximal to medial screw, 208 for the proximal to lateral screw and 498 and 546 Ncm for the diaphyseal pins. The corresponding forces for the HA-coated pins were not significantly different. The torque forces for the extraction of the standard pins were 2 Ncm for the proximal pins, 277 and 249 Ncm for the distal pins and 482, 478, 585 and 620 Ncm, respectively (p < 0.005) for the HA-coated pins. All 18 of the metaphyseal standard screws were loose at extraction (extraction force < 20 Ncm), but only one of the HA screws in the metaphysis was loose. In the diaphysis the standard screws lost about 40% of their fixation in contrast to the HA-coated screws which retained full fixation strength.

Adult↗

Is there any difference between vacuum mixing systems in reducing bone cement porosity?

Six vacuum mixing systems, Cemvac, Merck, Mitvac, Optivac, Osteobond, and Stryker, were tested using prechilled Palacos R bone cement to investigate the reduction of porosity compared to mixing at atmospheric pressure. In addition the Optivac, Osteobond, and Stryker were tested using Simplex P bone cement to find out if they were effective in reducing the porosity of a middle viscosity bone cement. All vacuum mixing systems reduced the number of macropores (> 1 mm) and micropores (0.1 mm < voids < 1 mm) and increased the density of both Palacos R and Simplex P. But only the Optivac, Stryker, and Merck systems reduced the area percentage of macropores with more than 50% compared to the control. When using Simplex P bone cement, all three mixing systems tested reduced the numbers and the area percentage of macropores compared to the control. The results show that vacuum mixing is effective in reducing the porosity in both a high viscosity cement such as Palacos R and a middle viscosity cement such as Simplex P. Not all systems tested were effective in reducing the number and size of large voids.

Absorptiometry, Photon↗

Evidence of somatic mutations in osteoarthritis.

We examined, cytogenetically and by in situ hybridization (ISH) techniques, the synovia, osteophytes, and articular cartilage from 32 patients with pronounced osteoarthritis (OA), a prevalent form of arthropathy characterized by progressive reduction of articular cartilage, and synovial samples from 17 control patients. In short-term cultures, clonal chromosome aberrations, in particular the gain of chromosomes 7 (+7) and 5 (+5), were found to be strongly associated with OA. These aberrations were found in almost 90% of the cultures from synovia and osteophytes, whereas only 1/11 synovial samples from joints unequivocally unaffected by OA had cells with +5 or +7. The in vivo nature of trisomy 7 was demonstrated by ISH on uncultured cells, and serial passaging showed that cells with +7 had a proliferative advantage in vitro. Thus, the combined data indicate that cells with somatic mutations appear early and may be influential in the disease process leading to OA.

Adult↗

The Porous-Coated Anatomic total knee experience. Special emphasis on complications and wear.

One hundred sixty knees in 141 patients with the Primary Porous-Coated Anatomic prosthesis (Howmedica, Rutherford, NJ) were evaluated after a follow-up period of 5.6 years (range, 1-10 years). One hundred six knees were in the latest follow-up evaluation, including clinical examination and a defined standing radiograph with a follow-up period of 6.3 years (range, 3-10 years). Survivorship analysis regarding the cumulative revision rate (including completion with a patellar component) was 0.88 at the 8-year and 0.84 at the 10-year follow-up examination. The clinical result was satisfying/good, with a mean Hospital for Special Surgery score of 83 (range, 39-97). Five percent had thinning greater than 30% of the tibial component. The wear was calculated to be 1.0 mm (range, 0-9 mm), including three revised tibial components with heavy wear. Excluding the revised cases, the wear was 0.7 mm.

Aged↗

Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration.

RATIONALE AND OBJECTIVES: Accurate registration of computed tomography (CT) images to the patient is crucial for computer-assisted surgery. Markers used in roentgen stereo-grammetric analysis (RSA) can be located in a CT scan using a novel approach and also can be located physically. Roentgen stereo-grammetric analysis data act as "ground truth" for the three-dimensional marker locations. METHODS: Two foam-bone phantoms were marked. The markers were scanned seven times with RSA, three times with axial CT, and contacted four times with a coordinate measuring arm. Root-mean-square (RMS) errors were derived for the registrations. RESULTS: Computed tomography and RSA data register to 0.15 mm RMS error. Computed tomography and arm data register to 0.25 mm. The markers are biocompatible, and the coordinate measuring arm is usable in an operating room. CONCLUSIONS: Typical in vitro registration errors are approximately 2 mm. The authors have developed a marker that provides superior registration, and a procedure that can be used for in vivo studies.

Biocompatible Materials↗

Does vacuum mixing of bone cement affect heat generation? Analysis of four cement brands.

Four different brands of bone cement (Palacos R, Simplex P, Sulfix, CMW 1) were tested for exothermic changes during polymerization at atmospheric pressure and under partial vacuum of 0.2 bar. Palacos R was also mixed at four pressure levels (1.0, 0.2, 0.12, and 0.05 bar). The peak temperature in the bone cement was 46 to 124 degrees C, depending on the measuring point. There was no difference in peak temperature or duration of temperature increase above 50 degrees C during the curing of cement whether mixed at atmospheric pressure or under partial vacuum at different pressure levels.

Biocompatible Materials↗