PubMed Health⌕ Search

Biomedical subjects

S Totterman

Publications and source records attributed to S Totterman.

35 records · Page 2Linked to original sources

Gadopentetate dimeglumine-enhanced chemical-shift MR imaging of the breast.

Standard T1-weighted MR images enhanced with gadopentetate dimeglumine show relatively minimal enhancement of breast lesions due to the high background signal from fat in the breast. Strongly enhancing lesions may become isointense relative to the fat signal and become invisible or indistinct after contrast administration. Fat-suppressed chemical-shift imaging (CSI) combined with administration of gadopentetate dimeglumine improves lesion detection and characterization in other areas of the body where a strong lipid signal is present. We evaluated this technique in the breast. Twenty patients with mammographic lesions were studied with standard unenhanced T1- and T2-weighted images and enhanced T1-weighted images, as well as with CSI before and after administration of gadopentetate dimeglumine. The series were ranked independently for border and matrix characteristics. The border was assessed for a smooth, irregular, or spiculated margin. The matrix or internal substance was evaluated for visibility and type of enhancement, homogeneous or inhomogeneous. The enhanced CSI images were superior to all other images in the depiction of border and matrix characteristics. Of 20 patients, a corresponding mass was detected on MR in 14. In two of the 14 patients, the lesion was seen only in the enhanced CSI images. Chemical-shift artifacts on enhanced T1-weighted images obscured border detail in several cases. Enhanced CSI improves visualization of breast lesions as compared with conventional MR imaging with or without enhancement. The enhanced CSI technique produces differential enhancement between glandular tissue and lesions while suppressing the signal from fat. This improves the visualization of border and matrix characteristics and depicts lesions that otherwise might be obscured.

Breast Neoplasms↗

Quantitation of venous clot lysis with the D-dimer immunoassay during fibrinolytic therapy requires correction for soluble fibrin degradation.

Plasma cross-linked fibrin-degradation products were analyzed using a D-dimer (DD) immunoassay in patients with deep vein thrombosis (DVT) or acute myocardial infarction (MI) treated with fibrinolytic therapy, and the results were correlated with clot lysis documented angiographically. In 13 patients with DVT, the mean DD concentration increased 10-fold (1,074 +/- 252 to 10,333 +/- 1,004 ng/ml) during therapy, but neither the peak level nor the DD concentration integrated over the course of therapy correlated with clot lysis. Since plasma DD can derive from degradation of soluble plasma fibrin as well as from thrombi, the contribution of the former was estimated by in vitro incubation of the pretreatment plasma with plasminogen activator. Subtraction of this value from the measured posttreatment DD concentration provided a "corrected" level that represented DD originating from lysis of thrombi. This modification resulted in improved correlation of DD levels with clot lysis. The mean corrected peak DD was higher in patients with successful thrombolysis (8,780 +/- 1,352 ng/ml) compared with patients without lysis (3,075 +/- 589 ng/ml, p less than 0.001). There was a moderate correlation between the volume of clot lysed and the corrected peak DD (r = 0.62) and a higher correlation with the corrected DD integrated over the course of treatment (r = 0.97). By contrast, the corrected DD concentrations were near zero in patients treated for MI with or without thrombolytic reperfusion, suggesting that fibrin in small coronary thrombi did not contribute significantly to total plasma DD during therapy.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Diagnosis of femoropopliteal venous thrombosis with MR imaging: a comparison of four MR pulse sequences.

In a prospective study, MR images were evaluated in seven patients with femoropopliteal venous thrombosis with symptoms of less than 5 days duration. T1-weighted (600/25 [TR/TE]), intermediate (2000/30), and T2-weighted (2000/100) spin-echo series and a gradient-recalled acquisition in the steady state (GRASS) series were compared. Using venography as the standard for diagnosis, we found GRASS to be the most sensitive of the MR techniques, showing thrombi in all patients. It provided good contrast between the low-intensity thrombus and high-intensity flowing blood and also between thrombus and intermediate- or high-intensity perivascular tissues. The T1-weighted series was the least sensitive technique. All thrombi showed heterogeneity in the transaxial image with differences in signal between the peripheral and central regions. A higher intensity signal in the center than in the periphery at some level of the thrombus was found in six of seven T2-weighted or GRASS images. Heterogeneity in the signal intensity was more frequent in distal portions of thrombi, whereas the most proximal extent was homogeneous in appearance in six of seven cases. The heterogeneous appearance may be related to the greater age of the distal thrombus, because deep venous thrombi are known to begin in the calf and extend proximally over time. We conclude, on the basis of our experience with a small number of patients, that the GRASS MR technique is more sensitive for detecting acute deep venous thrombosis than T1-weighted, intermediate, and T2-weighted MR images.

Adult↗

Prevention of venous thrombosis after total knee arthroplasty. Comparison of antithrombin III and low-dose heparin with dextran.

In a prospective, randomized trial, we compared the efficacy of a combination of antithrombin III and heparin with that of dextran 40 as prophylaxis against venous thrombosis after total knee arthroplasty. Ascending venography identified thrombosis in about one-third of the patients who received the combination of antithrombin III and heparin, compared with about four-fifths of those who received dextran (p less than 0.001). In both groups, the patients who had venous thrombosis had a significantly lower concentration of antithrombin III postoperatively than those who did not have thrombosis. Venous thrombosis occurred in all patients in whom the concentration of antithrombin III was less than 65 per cent postoperatively. These findings demonstrated that, after total knee replacement, the combination of antithrombin III and heparin effectively reduces the incidence of postoperative venous thrombosis and is significantly better than dextran. Furthermore, the findings suggested a relationship between postoperative deficiency of antithrombin III and the occurrence of thrombotic complications.

Adult↗

Reduced-bandwidth MR imaging of the head at 1.5 T1.

A decrease in the magnetic resonance (MR) imaging bandwidth can be used to increase the signal-to-noise ratio (S/N) at constant imaging time or to maintain the S/N for reduction of imaging time. The effect of bandwidth reduction from the default value of 16 kHz to 8 kHz was evaluated prospectively in 50 patients referred for MR imaging of the head. On intermediate (2,000/30 [repetition time msec/echo time msec]) and more T2-weighted (2,000/90) studies, there were no definite missed diagnoses and no diagnostically important changes in lesion characteristics when the reduced-bandwidth technique was used to obtain half- or quarter-time studies, excluding differences attributable to unintentional changes in patient position between image acquisitions. Chemical shift misregistration artifacts associated with reduced bandwidth are easily recognized with experience and do not interfere with diagnosis, as the artifacts occur in characteristic locations and diminish in most anatomic locations with increasing echo time. This study suggests the feasibility of reduced-bandwidth techniques in clinical MR imaging of the head at high field strength to achieve an increased S/N, to decrease imaging time, or to obtain images in additional projections.

Brain↗

Prevention of venous thrombosis after total hip arthroplasty. Antithrombin III and low-dose heparin compared with dextran 40.

The anticoagulant action of heparin is mediated through antithrombin III, and the postoperative decrease in the plasma concentration of antithrombin III may contribute to the relative ineffectiveness of prophylaxis with low-dose heparin in preventing venous thrombosis after total hip arthroplasty. We conducted a prospective, randomized trial to compare the effectiveness of a regimen of antithrombin III, given intravenously once daily, and low-dose heparin with a regimen of dextran 40, given intravenously, in preventing venographically documented venous thrombosis after total hip arthroplasty. The results demonstrated an incidence of venous thrombosis of 4.9 per cent in patients who received antithrombin III and heparin; this was significantly lower than the incidence (28.6 per cent) in patients who received dextran 40 (p less than 0.005). Venous thrombosis occurred only in patients who had total hip arthroplasty with a cemented prosthesis (fourteen of fifty-seven patients, or 24.6 per cent); none of the twenty-six patients in whom a non-cemented prosthesis was used had venous thrombosis (p less than 0.01). Of the patients in whom a cemented prosthesis had been inserted, the incidence of venous thrombosis was lower in those who were treated with antithrombin III and heparin (7.4 per cent) than in those who were treated with dextran 40 (40 per cent) (p less than 0.005). Postoperative levels of antithrombin III were maintained at more than 90 per cent of the baseline level in patients who received it; this was significantly higher than in patients who received dextran 40.(ABSTRACT TRUNCATED AT 250 WORDS)

Antithrombin III↗

Antithrombin III/low-dose heparin in the prevention of deep-vein thrombosis after total knee arthroplasty. A preliminary report.

This preliminary report outlines the rationale for a new approach to deep-vein thrombosis (DVT) prophylaxis in total knee arthroplasty (TKA) patients and describes preliminary hematologic and venographic findings. A protocol was employed to (1) document a series of hematologic events surrounding cemented TKA and the alterations of these events by the study drugs and (2) compare the safety and efficacy of a regimen of antithrombin III/low-dose heparin (ATIII/LDH) to that of low-molecular-weight dextran (LMWD) in the prevention of DVT after TKA. Using a dosage regimen of 3000 units of ATIII as a loading dose followed postoperatively by 2000 units daily combined with 5000 units of LDH twice daily, a prospective randomized study of patients treated by cemented TKA was performed. The ATIII/LDH regimen was compared with LMWD (10 ml/kg x 12 hours loading dose followed by 7 ml/kg x 24 hours maintenance dose). The rate of DVT after TKA in 42 patients was 25% (5/20) for the ATIII/LDH group versus 82% (18/22) for the LMWD group (p less than 0.001). Bleeding complications were minimal and comparable for each group. Hematologic studies demonstrated that quantitative and functional ATIII levels decreased after TKA and that preoperative loading with ATIII prevented levels from falling below 100%. Studies of clot formation (fibrinopeptide A) and plasmin activity (fibrinopeptides B beta 15-42 and 1-42) in 34 patients suggest some reduction in procoagulant activity in patients in the ATIII/LDH group. These findings indicate that the combination of ATIII and LDH may offer superior protection from DVT than does LMWD.

Antithrombin III↗

Switched surface coil system for bilateral MR imaging.

A method is presented for acquiring magnetic resonance (MR) images in parallel from both members of a pair of organs, such as the temporomandibular joint (TMJ), with use of two surface coil receivers. Interleaved sagittal sections are broken into two groups, one on each side of the head, and the MR receiver is toggled between the two coils. The surface coil that is not receiving at a given time is decoupled from the other surface coil by the active gating of a diode blocking network located across the coil input. This method produces effective decoupling independent of coil loading and positioning and makes it possible to use the same surface coils already employed for single-coil MR reception. Clinical application in 95 patients (190 joints) with symptoms of internal derangement of the TMJ demonstrated a 24% average decrease in total patient examination time, even after the addition of coronal imaging to the procedure. In no case was there a sacrifice in diagnostic quality.

Humans↗

Temporomandibular joint: MR assessment of rotational and sideways disk displacements.

The accuracy of coronal and sagittal magnetic resonance (MR) imaging was examined in the assessment of rotational and sideways displacements of the temporomandibular joint (TMJ) disk. Rotational disk displacement implies a combination of anterior and medial or lateral displacements, whereas sideways displacement implies pure medial or lateral displacement without an anterior component. Multiple 3-mm-thick coronal and sagittal MR images were obtained of 18 fresh TMJ autopsy specimens and compared with the observations in corresponding coronal cryosections. MR imaging correctly delineated the mediolateral position of the disk in 15 joints (83%) and incorrectly delineated it in three joints (17%). Osseous anatomy was correctly assessed in 17 joints (94%). On cryosections, six joints (33%) showed medial disk displacement and two joints (11%) showed lateral displacement. In five of these eight joints the medial or lateral displacement occurred in conjunction with an anterior displacement, that is, rotational displacement. Clinical MR imaging in 37 patients (61 joints with coronal images) showed medial or lateral disk displacement in 16 joints (26%). This study suggests that rotational and sideways displacements of the TMJ disk are an important aspect of internal derangement. The multiplanar capabilities of MR are suitable for an assessment of these abnormalities.

Adolescent↗

Fat-suppression MR imaging of the orbit.

The effect of fat suppression on orbital MR imaging was tested by using a derivative of the Dixon method called chopper fat suppression in eight normal volunteers and eight patients with normal conventional orbital MR studies. Chopper fat suppression requires no postacquisition image processing or increased scan time and can be applied through a wide range of T1 to T2 weighting. In normal orbits, fat suppression was found to be advantageous for imaging the lacrimal gland and the optic nerve. Using fat-suppressed T1- or intermediate-weighted sequences, 2000/30 (TR/TE), the optic nerve was recognized by its high signal intensity relative to adjacent CSF, dural sheath, and surrounding fat. The technique minimized loss of anatomic detail by reducing chemical shift misregistration artifact. Disadvantages included an overall lower orbital signal/noise ratio. When used in conjunction with a TR/TE combination carefully selected for both anatomic region of interest and suspected pathology, the fat-suppression technique has the potential for improving the visualization of orbital lesions.

Adult↗

Effects of the magnetic resonance contrast medium ferrioxamine methanesulfonate on systemic and renal hemodynamics in the anesthetized dog.

Ferrioxamine methanesulfonate (S-FDF) is a new magnetic resonance (MR) contrast agent developed to improve magnetic resonance imaging of the abdomen and pelvis. This stable complex of deferoxamine methanesulfonate and iron is excreted in the urine by glomerular filtration modified by active renal tubular resorption. This study examines the acute systemic and renal hemodynamic responses to this agent after intravenous administration either as an infusion of 25 mg/kg over 5 minutes or as a rapid bolus at a dose of 50 mg/kg. In eight anesthetized dogs, renal plasma flow (RPF) was measured with an electromagnetic flowmeter, and GFR was determined by the renal extraction of technetium-99m-DTPA. Mean arterial pressure (MAP), pulse rate, and a lead II ECG were assessed. At a dose of 25 mg/kg over 5 minutes, MAP decreased significantly (control 146.0 +/- 6.5 mm Hg vs. 107 +/- 18 mm Hg at 2 minutes; P less than .05). In two of the eight animals, the MAP dropped below 60 mm Hg. Significant decreases in GFR and RPF also were noted. All four of the animals receiving the rapid injection of S-FDF experienced profound hypotension (MAP less than 50 mm Hg). The drop in heart rate from 152 +/- 11.6 bpm to 121 +/- 4.9 bpm was associated with a marked depression of the ST wave in the lead II ECG. Further animal studies are needed to assess the mechanism of toxicity and a potential synergism of action with pentobarbital anesthesia.

Animals↗

Magnetic resonance imaging of muscle injury.

To further evaluate the role of magnetic resonance (MR) imaging in diagnosing and managing muscle injuries, eight patients with muscle pain or palpable masses were imaged. MR findings were correlated with clinical follow-up data. Increased signal was noted on T2-weighted images in torn and overused muscles. One extensively scarred muscle required surgical biopsy to exclude a fibrous tumor. Three partial muscle tears were treated conservatively. One complete musculotendinous junction tear required tendon transfer. MR studies noninvasively identified and staged various muscle injuries, thereby influencing management.

Adult↗

Relationship between the lateral acromion angle and rotator cuff disease.

One hundred consecutive magnetic resonance imaging (MRI) studies of the shoulder obtained for the purpose of evaluating rotator cuff symptoms were retrospectively reviewed to assess the relationship between acromion morphologic appearance and rotator cuff disease. The studies were reviewed simultaneously by two authors. Each cuff was assigned a tendon grade and an overall cuff score with MRI criteria previously described in the literature. A newly described "lateral acromion angle" was measured from a specified oblique coronal cut on each MRI study and was correlated with the corresponding MRI-determined rotator cuff score and supraspinatus tendon grade. Observed correlations were analyzed by using statistical methods. The average measured lateral acromion angle was 78 degrees, with a range from 64 degrees to 99 degrees. Eight shoulders had angles less than or equal to 70 degrees, and all eight of these patients were found to have full-thickness rotator cuff tears. As the lateral acromion angle decreased, a statistically significant increase in rotator cuff disease was noted (p < 0.0001). A significant correlation between increasing age and rotator cuff disease was also observed (p < 0.0001). Multiple regression analysis confirmed that both the lateral acromion angle and the age of the patient were independent predictors of rotator cuff score. Finally, although a trend was noted suggesting a correlation between acromion type (I--flat, II--curved, and III--hooked) and MRI-determined rotator cuff disease, this trend did not reach statistical significance (p = 0.12). Surgical correlation with MRI rotator cuff findings in 35 patients showed an MRI sensitivity of 100% and specificity of 83%. A statistically significant correlation between the lateral acromion angle and MRI-determined rotator cuff disease has been noted. The described angle may be a useful adjuvant in the evaluation and management of rotator cuff disease.

Acromioclavicular Joint↗

MR fat suppression technique in the evaluation of normal structures of the knee.

The chopper fat suppression (CFS) pulse sequence, which is a phase sensitive implementation of the Dixon fat suppression method and the spin echo (SE) pulse sequence, was used in the evaluation of anatomic structures of the normal knee using 48 sets of imaging sequences in six volunteers using a repetition time/echo time combination of 1,500/30, 60 ms. A demonstration of the CFS technique in 10 patients with suspected knee pathology is also presented. A semiquantitative grading scale was established to rate anatomic visualization and used to compare CFS and SE pulse sequence techniques. The results in normal subjects demonstrate that hyaline cartilage is significantly better visualized by fat suppression pulse sequence than by conventional SE pulse sequence in the coronal and sagittal planes of imaging (p less than 0.001). The preliminary results from patients studies suggest that CFS imaging may be useful in the evaluation of meniscal tears, in the differentiation of hyaline cartilage from joint fluid, and in the detection of both soft tissue and bone injuries.

Adipose Tissue↗

A comparison of default and reduced bandwidth MR imaging of the spine at 1.5 T.

The value of a reduced bandwidth MR imaging technique was tested prospectively in 51 spinal MR examinations by using default (16 kHz) bandwidth, 2000/30, 90 (TR/TEs) and 600/30, and reduced (8 kHz) bandwidth, 2000/48, 92 and 600/30, techniques at 1.5 T. Bandwidth reduction was used to maintain the signal-to-noise ratio for a reduced scan time. Concerns have been raised as to the effect of bandwidth reduction at high field, since a savings in time or an increased signal-to-noise ratio occur at the expense of increased chemical shift misregistration artifact. However, when appreciable, the chemical shift-related artifact in the spine was typically located in the frequency-encoding direction at the vertebral body/disk space interface or the dural sac/epidural fat interface in the lower lumbosacral region and was easily distinguished from pathologic lesions. There were no missed diagnoses with the reduced bandwidth technique. This study suggests that chemical shift-related artifact will rarely be confused with pathology by an experienced reader and suggests a clinical role for the bandwidth technique to decrease scanning time in uncooperative patients or to allow acquisition of additional imaging planes in a reasonable time.

Adolescent↗

Dual cervical thoracic coil for spine magnetic resonance imaging.

The need for repositioning of surface coils and patients in MR examinations of the cervical and thoracic spine prolongs examination time. A new receiver design is proposed which overcomes this problem. The device is composed of two actively decoupled receiver coils mounted on the frame of a Philadelphia collar. These coils may be used separately to image either the thoracic or cervical spine or together to produce larger field-of-view images of the combined region. Signal-to-noise ratios of the separate cervical and thoracic spine images are not degraded as a result of mounting the receivers together. The full cervical and thoracic region is shown to be imaged at a signal-to-noise ratio significantly higher than that afforded by the body coil. A retrospective review of our case load suggests that a time saving could be achieved in approximately 1/3 of spine examinations by using this coil.

Humans↗

Monitoring of therapy for deep vein thrombosis using magnetic resonance imaging.

Magnetic resonance imaging using limited-flip-angle, gradient refocused pulse sequences has been used to monitor the course of anticoagulant or fibrinolytic therapy for deep vein thrombosis in two patients. The findings demonstrate the capacity of this technique to delineate the extent of thrombosis and characterize changes in size in response to treatment. Advantages of this approach include high anatomic resolution, speed of examination and non-invasiveness, properties that make it well-suited to following the progress of therapy with potentially significant implications for improving treatment.

Adult↗