PubMed Health⌕ Search

Biomedical subjects

S Urbaniak

Publications and source records attributed to S Urbaniak.

15 recordsLinked to original sources

Collaborative study to establish the first international standard for quantitation of anti-HPA-1a.

BACKGROUND AND OBJECTIVES: This report describes the production of a freeze-dried preparation of pooled human plasma, containing immunoglobulin G (IgG) antibodies against the human platelet antigen 1a (HPA-1a). The material, coded 03/152, is proposed as an International Standard containing 100 arbitrary units of anti-HPA-1a for use in quantitative assays to determine the anti-HPA-1a activity in clinical samples. MATERIALS AND METHODS: Plasma samples containing potent anti-HPA-1a were pooled and freeze dried in 1-ml ampoules. In addition, three individual plasma samples were selected which had varying levels of anti-HPA-1a activity. The anti-HPA-1a activity of these three samples was determined by using a variety of quantitative assays with the proposed standard as a reference. RESULTS: An international collaborative study, which was part of the 2004 ISBT Platelet Immunology Workshop, involved 39 laboratories in 24 countries and showed that the anti-HPA-1a activity in three test samples could be reliably determined by using the proposed standard. CONCLUSIONS: Laboratories can use this standard to measure the anti-HPA-1a activity in patient's samples. Further studies are required to determine the relationship between anti-HPA-1a activity and clinical outcome in patients with neonatal alloimmune thrombocytopenia (NAIT).

Antibodies, Monoclonal↗

The supply of blood products in 10 different systems or countries.

Countries vary greatly in their ability to produce their own blood products including albumin and IVIgG. Part of this variability depends on the supply of plasma within the country. As has been seen most recently in the UK, the quality of the plasma and its acceptability for plasma fractionation must also be considered. Therefore concerns regarding the quality of the plasma have been added to those regarding the quantity.Only a few countries are nationally self sufficient in plasma. This has a marked effect on blood product availability and therefore the ability to treat patients. Unlike most pharmaceuticals, the plasma fractionation industry must rely, for its raw products, on plasma obtained from blood donors. As such this puts it in a potentially compromised situation since neither the supply nor the quality of the raw material can be assured and both of those will vary with time. This paper reviews the processes through which blood products are made available in 10 different systems including: Canada, England, France, Italy, Norway Scotland, Sweden, Switzerland, South Africa and USA. A series of specific questions were posed and the responses received from the various coauthors and other respondents provide comparative data on blood product availability in different areas of the world.

Blood Banks↗

An international trial demonstrates suitability of a newly developed whole-blood ELISA kit for multicentre platelet HPA-1 phenotyping.

BACKGROUND: Neonatal alloimmune thrombocytopenia (NAIT) is in most cases due to pregnant women with HPA-1b platelet phenotype producing antibodies to HPA-1a platelets of the fetus, which may lead to intracranial haemorrhage with subsequent death or life-long morbidity. The availability of sensitive, reliable, straightforward, and inexpensive assays would enable large-scale screening in pregnancy and may help avoid NAIT. METHODS: A recently developed enzyme-linked immunosorbent assay (ELISA) was produced in kit form incorporating modified reagents and enabling distribution to 21 international Platelet Immunology and Blood Centres (see Acknowledgements). The kits were assessed using anticoagulated whole-blood samples stored up to 10 weeks at 4 degrees C. Each centre tested its own blood samples most of which had been previously typed by established assays. RESULTS: Of the 152 samples that were tested, all 31 HPA-1b phenotypes were correctly identified by the kit. The respective mean +/- standard deviation of the specific absorbances of HPA-1b and HPA-1a samples were: 0.52+/-0.15 and 0.12+/-0.06 (p<0.0005). In addition, the modified ELISA showed 100% concordance with PCR-SSP in the phenotyping of 93 donors. Finally, a comparison between freshly prepared and stored kits showed that the kit was stable for at least 2 years at 4 degrees C. CONCLUSIONS: The international trial showed that the modified whole-blood ELISA kit is very well suited for wide-scale screening in pregnancy. Moreover, the ELISA kit could be used for large-scale phenotyping of blood donors, with HPA-1b-typed individuals getting invited to become apheresis platelet donors for patients with NAIT.

Adult↗

IgG from patients with antiphospholipid syndrome binds to platelets without induction of platelet activation.

The clinical manifestations of the antiphospholipid syndrome (APLS) include arterial and venous thrombosis, thrombocytopenia and fetal loss, but the pathogenic mechanisms remain unclear. It has been hypothesized that platelet activation by autoantibody may be a pathogenic mechanism. We studied IgG binding, microparticle (mp) formation and P-selectin expression by flow cytometry in normal platelets after incubation in serum from 11 patients with antiphospholipid antibodies and that from 10 normal healthy subjects. Levels of platelet-associated IgG were significantly higher after incubation in patient sera (mean 17.2, range 2.0-75.0%) compared with normal sera (mean 2.0, range 1.2-3.7%, P<0.05). Incubation of normal platelets in serum led to increased microparticle formation (P<0.01) and P-selectin expression (P < 0.05), compared with unstimulated platelets. There was no significant difference, however, between microparticle formation nor P-Selectin expression induced by patient serum (mp 3.0 (1.6-5.0)%; P-selectin 8.0 (4.0-16.6)%) versus normal serum (mp 3.2 (2.1-4.5)%; P-selectin 10.1 (4.0-15.6); median (range)). Pre-activation of platelets with sub-threshold ADP concentrations or thrombin receptor activator peptide resulted in a small increase in microparticle formation, but there was still no significant difference between the effects of patient and control sera. Despite the presence of platelet membrane binding IgG in serum from 5/11 patients with antiphospholipid antibodies, there was no evidence for associated enhanced platelet-activating ability. This study supports antiplatelet reactivity in antiphospholipid syndrome, but not a direct platelet-activating role for platelet-directed autoantibodies.

Antibodies, Antiphospholipid↗

Renal transplantation: HLA-linked, non-cytotoxic antibodies develop after blood transfusion.

1. A previously untransfused dialysis patient was given blood from a single donor on three occasions and sera were obtained from the recipient before and after transfusion. 2. The sera were tested against B-lymphocytes from the blood donor and his family in the erythrocyte-antibody rosette inhibition assay to determine whether any Fc-receptor-blocking activity which developed was HLA linked. 3. Antibody activity was noted after the second transfusion and was directed toward B-lymphocytes from the blood donor and his family members sharing the haplotype HLA A11, B12 with him. 4. These antibodies were removed by the absorption of active sera with lymphocytes from the blood donor but not from (a) his sibling who shared no HLA antigens with him or (b) the transfusion recipient. Absorption of the active sera with platelets from the blood donor did not remove activity. 5. These results indicate that Fc-receptor-blocking antibodies developing after blood transfusion are directed to HLA-linked antigens on donor lymphocytes.

Absorption↗

Evidence that protective Fc-receptor-blocking antibodies in renal transplantation are alloantibodies not autoantibodies.

We have previously shown that the presence in pretransplant recipient sera of Fc receptor blocking antibodies detected by the EA inhibition assay is correlated with improved allograft survival. Twenty-four such sera were assessed for the presence of autoantibodies by the EA inhibition and lymphocytotoxicity assays. No autolymphocytotoxic antibodies were found, and autologous EA inhibition was noted in only one case. EA-inhibiting alloantibodies did occur, and their presence was correlated with improved allograft survival. Sera from 37 dialysis patients were also studied, and neither autologous EA inhibiting nor autologous lymphocytotoxic antibodies were present. Thus Fc receptor blocking alloantibodies that were correlated with improved renal transplant survival were not autoantibodies.

Autoantibodies↗

Placental proteins in male serum.

Placental proteins such as human chorionic gonadotrophin (hCG), Schwangerschaftsprotein 1 (SP1) and pregnancy-associated plasma protein A (PAPP-A) are found in the blood of pregnant women and in subjects suffering from cancer. They can also be found in the blood of healthy non-pregnant women and in the seminal fluid of males. Surprisingly, hCG and SP1 could not be found in male serum, although PAPP-A occasionally occurs there.

Adolescent↗

HLA antigens and other risk factors in the development of retinopathy in type 1 diabetes.

Factors possibly influencing the development of diabetic retinopathy were studied in 112 randomly selected type 1 diabetics having no or minimal retinopathy (group A) and in 82 type 1 diabetics with known severe diabetic retinopathy. The latter comprised those with severe background retinopathy (group B, n = 17) and those having proliferative retinopathy without (group C, n = 38) and with group D, n = 27) diabetic nephropathy. Nonretinopaths (group A) were of similar sex ratio, body weight, and age at diagnosis of diabetes but had been diabetic longer (p less than 0.001) and were thus older (p less than 0.001) than retinopaths (groups B-D). The distribution of HLA antigens of the A, B, and C loci was similar in nonretinopaths and retinopaths with the exception that HLA B7 showed a reduced (p less than 0.05) prevalence in the retinopaths (6% versus 17%) and was singularly underrepresented in group D, where no patients had this antigen. Mean postprandial plasma glucose and HbA1 concentrations were higher (p less than 0.01 and p less than 0.001) and cigarette smoking was more prevalent (p less than 0.01) in the retinopathy groups B-D than in group A. Systolic and diastolic blood pressures were similar in groups A-C, with higher (p less than 0.001) values only in group D. There was no association between insulin antibody binding in the serum or measurable plasma C-peptide immunoreactivity and retinopathy status. The risk of development of diabetic retinopathy in type 1 diabetes may be related to HLA-associated genetic factors and to cigarette smoking.

Adult↗

Frozen red cells in Rhesus immunization.

The use of frozen washed cells in varying doses in primary Rh immunization is compared to two groups of men with the use of fresh washed cells in a third group. In the first two groups, using frozen cells, doses ranging from 0.5 to 20 ml of whole blood (Group I) are compared with a 200.0 ml dose of red cell concentrate (Group II), while Group III served as a control using a 20 ml dose of fresh washed red cell suspension (9.0 ml concentrated red cell equivalent). The response rate was 93% in Group II compared with only 43% in Group I, suggesting the desirability of using relatively large doses of Rh-positive red cells for primary Rh immunization. The use of frozen washed cells from a special panel for 'booster' injections is also recommended.

Blood Preservation↗

Spontaneous resolution of lichen myxoedematosus.

Lichen myxoedematosus was diagnosed in a 44-year-old woman in 1957. Despite the persistence of an abnormal serum protein, the skin lesions cleared by 1965. The protein abnormality disappeared several years later.

Female↗

Cost-effectiveness of antenatal anti-D prophylaxis.

This paper estimates the incremental cost-effectiveness of providing antenatal anti-D prophylaxis in varying dose sizes to either primigravidae or all Rh D negative women. It presents a model for calculating the net cost per 1000 'at risk' women based on the costs of anti-D prophylaxis and the future NHS costs avoided. Incremental cost-effectiveness is measured in terms of the net cost per Rh D-alloimmunization and the net cost per Rh HD loss prevented. Programmes for Rh D negative primigravidae are more cost-effective than the same dose protocol extended to all Rh D negative women. The 1 x 1250 iu programme is the most cost-effective option.

Cohort Studies↗