Publications and source records attributed to S V Rithalia.

At least 19 recordsLinked to original sources

Assessment of alternating-pressure air mattresses using a time-based pressure threshold technique and continuous measurements of transcutaneous gases.

Alternating-pressure air mattresses (APAMs) are used increasingly for the prevention and treatment of pressure sores. Laboratory evaluation techniques have centred largely on interface pressure (IP) measurement, typically analysing discrete maximum and minimum levels, or average pressure. However, since pressure relief varies with time, a time-based analysis technique has been developed for performance assessment. IP was recorded continuously, and the duration of pressures below three thresholds (30, 20 and 10 mmHg) was calculated automatically using a computerized rig. Fifteen healthy volunteers were used to evaluate the pressure-relieving characteristics of four APAMs, including one overlay. Results indicated significant differences (P < 0.001) between products when durations below the 20 and 10 mmHg thresholds were analysed, showing that some devices were only capable of momentarily relieving pressure. Maximum contact pressures on the sacrum were significantly lower (P < 0.0001) on devices whose inflation pressure was adjusted according to subject's body mass. This technique could assist in the selection of alternating or dynamic surfaces of any description with further clinical validation.

Adult↗

Quantification of pressure relief using interface pressure and tissue perfusion in alternating pressure air mattresses.

OBJECTIVE: To examine whether the interface pressure (IP) relief provided by alternating pressure air mattresses (APAMs) is matched with maintenance of tissue perfusion over the points of contact by measuring transcutaneous oxygen and carbon dioxide (tcPO2, tcPCO2). DESIGN: Comparative analysis of 2 APAMs with a 2-parameter continuous time-based method for quantifying pressure relief (PR) and transcutaneous gas measurement for assessing tissue perfusion. SETTING: Rehabilitation research facility in a university hospital. PARTICIPANTS: Eleven able-bodied adult postgraduate student volunteers. MAIN OUTCOME MEASURES: Two full-replacement APAM systems were used. For each mattress the mean maximum and minimum interface pressures; mean peak air pressures in the mattresses; interface pressure durations below 30, 20, and 10 mmHg over a 60-minute period; mean maximum tcPCO2 and minimum tcPO2; and mean area under the tcPO2 and tcPCO2 curves were measured for each subject. RESULTS: IP on the sacrum was held below thresholds of 30, 20, and 10 mmHg longer on a 2-cell, low pressure system than on a 3-cell, high pressure system (p < .001). Integrated over time, tcPO2 levels also indicated that the 2-cell system retained oxygen levels closer to the unloaded baseline than did the 3-cell system (p < .01). tcPCO2 levels did not rise significantly (p > 0.1) compared with the baseline measurement in both mattresses. CONCLUSIONS: PR was sensitive to the design of the APAM, especially its inflation pressure, cycle time, and inflation sequence. If future trials demonstrate that PR values and transcutaneous blood gas measurements correlate significantly with the clinical incidence of pressure sore formation, then this technique may prove useful in assessing the effectiveness of alternating pressure support surfaces.

Adult↗

A change for the better? Measuring improvements in upgraded alternating-pressure air mattresses.

This study used measurements of interface pressure over time (the pressure relief index) to investigate improvements made to two alternating-pressure air mattresses. Two older models, the Nimbus 2 (Huntleigh Technology) and Pegasus Airwave (Pegasus Egerton), were compared with two new versions, the Nimbus 3 and Cairwave systems, respectively. Pressure relief was improved in seven out of 12 areas in the Nimbus 3 system, and in four out of 12 areas in the Cairwave. Significant differences in pressure relief index measurements at the heel between the Nimbus 3 and Cairwave products may explain the former's better clinical outcomes in this area, but superior pressure relief index performance at the sacrum did not predict better clinical outcomes. Therefore, different levels of pressure relief may be needed at different body sites. Individual practitioners must decide whether these improvements merit list price increases of 11% and 15%, respectively, and whether other features justify a 20% price difference between the two new systems.

Adolescent↗

Assessment of alternating air mattresses using a time-based interface pressure threshold technique.

Laboratory evaluation techniques for support surfaces have centered largely around interface pressure (IP) measurement, typically analyzing discrete maximum and minimum levels, or calculating the average pressure. Nowadays, alternating pressure air mattresses (APAMs) are used increasingly for the prevention and treatment of pressure sores. Pressure relief (PR) provided by an APAM is time-varying. A computerized system that measures IP, air pressure, and pressure-time characteristics of dynamic support surfaces has been developed for performance assessment. Using this system, IP was recorded continuously and the durations of pressures below three thresholds (30, 20, and 10 mmHg) were calculated automatically. Fifteen sound volunteers were used to evaluate the pressure-relieving characteristics of four APAMs, including one overlay. Results indicated significant differences (p < 0.001) between products when durations below 20 and 10 mmHg thresholds were analyzed, showing some devices were only capable of momentarily relieving pressure. Maximum contact pressures on the sacrum were significantly lower (p < 0.0001) on devices where inflation pressure was adjusted according to the body mass of the subject. With further clinical validation, this tool could assist in the selection of alternating surfaces of any description.

Beds↗

Pressure relief characteristics in alternating pressure air cushions.

In this study a computerised system was used which continuously measured air pressure, interface pressure and pressure-time cycle characteristics of an alternating pressure air cushion (APAC), and calculated the time the interface pressure remained below three chosen thresholds of 20, 40 and 60 mm Hg. Ten healthy volunteers were used to evaluate the pressure relieving characteristics of four APACs. Results indicated significant differences between products when the threshold periods were analysed, showing some devices were not capable of relieving interface pressures below 20 mm Hg. Though deflation pressure decreased to nearer zero, interface pressure did not follow suit.

Adult↗

Comparison of transcutaneous oxygen and carbon dioxide monitors in normal adults and critically ill patients.

The performance characteristics of two transcutaneous combined PO2 (tcPO2) and PCO2 (tcPCO2) sensors were compared with single tcPO2 and tcPCO2 electrodes in critically ill patients. The relationship between arterial blood gases (PaO2, PaCO2) and transcutaneous values was linear. Correlation coefficients (r) varied from 0.79 to 0.87 for tcPO2 and 0.92 to tcPCO2. The tcPO2 readings were always lower than PaO2 values, but the tcPCO2, with modified calibration of the electrodes, did not differ significantly from PaCO2. There was no significant difference of clinical importance in the performance of the three monitoring systems.

Adult↗

Mind that bolus!

Explore the source record for details and available documents.

Equipment Failure↗

Effects of ambulation on the blood flow in paralysed limbs.

Non-invasive transcutaneous blood gas monitoring techniques have been used as indicators of the effect of standing exercise on circulation in paraplegic subjects. Oxygen (tPO2) and carbon dioxide (tPCO2) electrodes were positioned on the chests and legs of a group of normal control subjects and a group of paraplegic subjects in both rested sitting and post-ambulatory standing. It has been shown that, with one possible exception, there is no significant difference in the transcutaneous blood gas partial pressures of O2 and CO2, and thus, by inference, in the circulation of paraplegics when either sitting or standing.

Adolescent↗

Effect of intermittent pneumatic compression on lower limb skin perfusion.

Transcutaneous oxygen (tcPO2) and carbon dioxide (tcPCO2) measurements were used before, during, and after intermittent pneumatic compression (IPC) to assess lower limb skin perfusion in 21 healthy adult volunteers and 23 elderly patients. The temperature of the sensors was set at 44 degrees C during calibration and maintained throughout all tests. Resting tcPO2 was significantly lower (p less than 0.01) in patients than in controls. In all subjects tcPO2 decreased and tcPCO2 increased during compression. Patients showed a highly significant increase (p less than 0.001) in tcPCO2 during and after the treatment. Results of this study indicate that the symptomatic improvement, in peripheral vascular disease and wound healing following IPC, is not due to improved skin perfusion or enhancement of oxygenation and CO2 removal.

Aged↗

Effect of intermittent pneumatic compression on lower limb oxygenation.

The effect of intermittent pneumatic compression (IPC) of the lower limbs on transcutaneous oxygen tension (tcPO2) was studied in 14 healthy volunteers and the same number of elderly patients. The oxygen sensor was calibrated at 37C in room air. This temperature was also used for measurements. Compression pressure in the IPC garment was standardized to 50mmHg inflation and zero mmHg deflation. Cycle time was set to 30 seconds inflation and 30 seconds deflation. It was found that using this combination of pressure and cycle times, tcPO2 fell during compression in all subjects and returned to the precompression level after the treatment. Although reactive hyperemia of various intensities occurred in some subjects after compression, tcPO2 did not rise significantly above the resting level. This suggests that the symptomatic improvement reported by patients treated with IPC was more likely to be due to enhanced removal of metabolites and supply of nutrients than to an improvement in leg oxygenation.

Adult↗

Characteristics of transcutaneous carbon dioxide tension monitors in normal adults and critically ill patients.

The performance of three electrodes used for transcutaneous carbon dioxide (tcPCO2) monitoring is compared in 15 healthy volunteers and 26 critically ill adults. All three electrodes showed good correlation between tcPCO2 and arterial blood PCO2 (PaCO2) with a correlation coefficient (r) greater than 0.86. There was little difference in the performance characteristics of the three monitors. They may be usefully employed to estimate PaCO2 values when used with a modified calibration recommended by the manufacturers.

Adult↗

Medical technology. Transcutaneous carbon dioxide monitoring.

Transcutaneous PCO2 electrodes are noninvasive, reliable, and accurate indicators of the trend in arterial PCO2. Their combination with occasional arterial sampling allows them to be calibrated in vivo for use in a wide range of patients, even in the presence of a severely compromised haemodynamic state. Their role in the ITU as monitors of continuous ventilation and during weaning has been established. However, their potential for use during anaesthesia, acute asthma, exacerbations of chronic airflow limitation, and in studies into the normal and abnormal mechanisms of ventilation during sleep has yet to be realized.

Animals↗

Continuous flush devices for vascular pressure monitoring.

Six different types of continuous flush devices have been assessed for accuracy in vitro and ease of use in vivo. Only two types of device matched the manufacturers' specifications of performance. The other four gave higher flow rates than expected.

Blood Pressure↗