PubMed Health⌕ Search

Biomedical subjects

S V Sheppard

Publications and source records attributed to S V Sheppard.

5 recordsLinked to original sources

Does leucocyte depletion during cardiopulmonary bypass improve oxygenation indices in patients with mild lung dysfunction?

BACKGROUND: Leucocyte-depleting arterial line filters have not dramatically improved lung function after cardiopulmonary bypass (CPB), but patients with pre-existing lung dysfunction may benefit from their use. METHODS: We randomized 32 patients with mild lung dysfunction having elective first-time coronary revascularization to either a leucocyte depleting or a standard 40-mm arterial line filter during CPB. The alveolar arterial oxygenation index was calculated before and 5 min after CPB, then at 1, 2, 4, 8, and 18 h after surgery. Time to extubation on the ITU was recorded. Preoperative, immediate postoperative, and 24 h postoperative chest x-rays were scored for extravascular lung water. RESULTS: Postoperative alveolar-arterial oxygenation indices were better in the patients who received leucocyte depletion during CPB (1.65+/-0.96 in the study group vs 2.90+/-1.72 in the control group, P<0.05). The duration of postoperative mechanical ventilation was less in the leucocyte-depleted group (4.8+/-2.1 vs 8.3+/-4.7 h in the control group, P<0.05). The extravascular lung water scores immediately postoperatively were 13.0+/-8.6 in the study group vs 19.6+/-10.8 in the control group (P=0.04), and at 24 h postoperatively, 9.7+/-7.7 vs 15.2+/-9.9 for controls. CONCLUSIONS: For patients with mild lung dysfunction, a leucocyte-depleting arterial line filter improves postoperative oxygenation, reduces extravascular lung water accumulation, and reduces time on artificial ventilator after CPB. There may be an economic argument for the routine use of leucocyte-depleting filters for every patient during CPB.

Adolescent↗

Does the use of leucocyte depletion during cardiopulmonary bypass affect exhaled nitric oxide production?

Fifty patients undergoing elective coronary revascularisation were prospectively randomised to receive either a leucocyte-depleting or a control filter inserted into the arterial line of the cardiopulmonary bypass (CPB) circuit. The concentration of exhaled nitric oxide (NO) was measured 15 min before and 30 min after CPB using a real-time chemiluminescence analyser (Logan Research, Northampton, UK). The baseline rate of exhaled NO production was 2.14 +/- 0.83 ppb/s in the control group, and 2.58 +/- 0.53 ppb/s in leucocyte-depleted group (p = 0.17). Following CPB, the mean rate of exhaled NO production in the control group had increased by 1.51 +/- 0.45 ppb/s to 3.65 +/- 0.81 ppb/s and in the leucocyte- depletion group had increased by 1.05 +/- 0.45 ppb/s to 3.64 +/- 0.62 ppb/s. The increase in exhaled NO production was significantly lower in the leucocyte depleted group (p = 0.002), indicating that leucocyte depletion suppressed the increase in exhaled NO production seen following CPB.

Aged↗

When is extracorporeal life support worthwhile following repair of congenital heart disease in children?

BACKGROUND: Although the use of extracorporeal life support (ECLS) following repair of congenital heart defects in children is increasing, the criteria for ECLS usage in these patients is not well defined. The overall survival of such patients is disappointingly low and may depend on both the indication for support and the time at which ECLS is commenced. METHODS: Between January 1993 and December 1996, 727 children underwent surgery for congenital heart defects at our institution with an overall hospital mortality of 5.8% (42 children). Nine of these children were treated with ECLS postoperatively. There were seven males and two females with a mean age of 7.2 months (range 2 weeks-3 years). Seven children could not be weaned from cardiopulmonary bypass (CPB) in the operating theatre. A further two were treated with ECLS later on during the postoperative period (commenced at 14 and 48 h). Full veno-arterial extra corporeal membrane oxygenation (ECMO) support was used in all children except one in whom a left ventricular assist device (LVAD) was used. RESULTS: The median duration of support was 121 h (range 15-648 h). Four children (44%) were weaned from support and two of these are long-term survivors. Of the seven children in whom ECLS was instituted because of failure to wean from CPB, there was one long term survivor (LVAD support). Of the two patients in whom ECLS was instituted during the post-operative period there is one long-term survivor. CONCLUSIONS: Weaning form ECLS and decannulation in 44% of our patients is comparable to other series of post-cardiotomy patients requiring ECLS. However, full veno-arterial ECMO instituted because of a failure to wean from CPB during corrective surgery is associated with an extremely poor outcome (zero long-term survivors in six patients).

Child, Preschool↗

PULMONOLOGIST: a computer-based diagnosis system for pulmonary diseases.

PULMONOLOGIST is a prototype expert system designed as a decision-making aid for physicians in providing accurate diagnosis and treatment of lung diseases. Disease information in the system has been encoded in the form of rules and schemata. The system has been developed using the expert system building tool ART (Automated Reasoning Tool) from Inference Corporation. This paper gives a brief introduction to the expert system concept, and includes a detailed description of the diagnosis system. This system will be tested against clinical data in future studies.

Diagnosis, Computer-Assisted↗