Contrasting heating patterns and efficiency of the Prostatron and Targis microwave antennae for thermal treatment of benign prostatic hyperplasia.

OBJECTIVES: To determine the design and performance characteristics of two microwave antennae for use in thermal treatment of benign prostatic hyperplasia. METHODS: Prostatron and Targis antennae were subjected to detailed physical examination and measurement. The heating patterns generated by these two types of antennae were characterized in detail using tissue-equivalent phantoms. Measurements of return loss as a function of frequency were conducted to evaluate the capacity of the antennae for impedance matching. Percent reflected power was calculated from the return loss results to provide a relative measure of potential for efficient delivery of thermal energy. RESULTS: The Prostatron antenna was found to be a monopole design consisting of a coaxial cable with a 3.3-cm length of inner conductor exposed at the tip. The Targis antenna was observed to be a dipole design with a 2.8-cm helical coil attached through a ground connection and a tap point to a coaxial cable. The heating pattern of the Targis antenna was symmetric; that of the Prostatron was asymmetric with substantial back heating along the catheter axis in the direction of the microwave power source. The mean extension of the 30 degrees C isotherm in the direction of the power source with the Prostatron antenna (71.5 mm; 95% confidence interval [CI], 63.4 to 79.6 mm) was 55% greater (P < 0.0005) than that with the Targis antenna (46.0 mm; 95% CI, 38.2 to 53.8 mm). Return loss with the Targis antenna declined sharply to a relative minimum value of -32.9 dB (95% CI, -73.8 to 8.0 dB) at 915 MHz, providing evidence of this antenna's capacity for impedance matching; little change was observed with the Prostatron in return loss over a frequency range 100 MHz above and below this antenna's standard operating frequency of 1296 MHz. The mean reflected power of the Targis antenna (0.4%; 95% CI, 0.0% to 1.4%) was lower by more than 20-fold (P = 0.036) than that of the Prostatron antenna (11.0%; 95% CI, 3.4% to 18.7%); thus, the potential for efficient operation was greater with the Targis than the Prostatron antenna. CONCLUSIONS: The Targis microwave antenna was found to provide a more targeted heating pattern and have a capacity for more efficient thermal energy delivery than the Prostatron antenna. These differences observed in vitro could potentially translate into clinical advantages in vivo, such as improved tolerability of microwave treatment, reduced risk of complications, greater thermoablative efficacy, and scalability.

Diathermy↗

Dynamic image-adaptive x-ray beam limiters.

The imaging capability of the dynamic spatial reconstructor (DSR), a fast (60/second), synchronous, multislice (up to 240) computed x-ray tomography scanner, has been limited by the suboptimal match of the dynamic range of the x-ray projection images with that of the image-intensified charge-coupled device (CCD) video sensors. Effective blockage of the "raw" beam component of the projection images by fixed shutters is generally impossible because of the rapid change in the multiple angles of view that result from the 15 RPM rotation of the scanner assembly about the object of study. For this reason a programmable, dynamic, image-adaptive x-ray beam shutter system has been developed to reduce the "raw" beam component of the x-ray image without degrading the image in the region of interest. This system is designed to dynamically position 28 shutters (two for each of 14 x-ray sources) continuously and independently, as a function of the angle of view, so as to selectively obscure any unattenuated "raw" x-ray beam passing alongside the object of study at all angles of view for each x-ray source.

Equipment Design↗