Transfer of normal 99mTc-ECD brain SPET databases between different gamma cameras.

A stereotactic, normal perfusion database is imperative for optimal clinical brain single-photon emission tomography (SPET). However, interdepartmental use of normal data necessitates accurate transferability of these data sets. The aim of this study was to investigate transfer of three normal perfusion databases obtained in the same large population of healthy volunteers who underwent sequential scanning using multihead gamma cameras with different resolution. Eighty-nine healthy adults (46 females, 43 males; aged 20-81 years) were thoroughly screened by history, biochemistry, physical and full neurological examination, neuropsychological testing and magnetic resonance imaging. After injection of 925 MBq technetium-99m labelled ethyl cysteinate dimer (ECD) under standard conditions, 101 scans were acquired from all subjects (12 repeat studies) on a triple-head Toshiba GCA-9300A (measured average FWHM 8.1 mm). Ninety-one sequential scans were performed on a dual-head Elscint Helix camera (FWHM 9.6 mm) and 22 subjects also underwent imaging on a triple-head Prism 3000 (FWHM 9.6 mm). Images were transferred to the same processing platform and reconstructed by filtered back-projection with the same Butterworth filter (order 8, cut-off 0.9 cycles/cm) and uniform Sorensen attenuation correction (mu = 0.09). After automated rigid intrasubject registration, all subjects were automatically reoriented to a stereotactic template by a nine-parameter affine transformation. The databases were analysed using 35 predefined volumes of interest (VOIs) with normalisation on total VOI counts. For comparison, the high-resolution data were smoothed with a 3D Gaussian kernel to achieve more similar spatial resolution. Hoffman phantom measurements were conducted on all cameras. Partial volume effects after smoothing varied between -6.5% and 10%, depending on VOI size. Between-camera reproducibility was 2.5% and 2.7% for the Toshiba camera versus the Helix and the Prism database, respectively. The highest reduction in between-camera variability was achieved by resolution adjustment in combination with linear washout correction and a Hoffman phantom-based correction. In conclusion, transfer of normal perfusion data between multihead gamma cameras can be accurately achieved, thereby enabling widespread interdepartmental use, which is likely to have a positive impact on the diagnostic capabilities of clinical brain perfusion SPET.

Adult↗

Hydrodynamic characterisation of ventricular assist devices.

A new mock circulatory system (MCS) was designed to evaluate and characterise the hydraulic performance of ventricular assist devices (VADs). The MCS consists of a preload section and a multipurpose afterload section, with an adjustable compliance chamber (C) and peripheral resistor (Rp) as principal components. The MCS was connected to a pulse duplicator system for validation, simulating a wide range of afterload conditions. Both pressure and flow were measured, and the values of the different components calculated. The data perfectly fits a 4-element electrical analogon (EA). The MCS was further used to assess the hydrodynamic characteristics of the Medos VAD as an example of a displacement pump. Data was measured for various MCS settings and at different pump rates, yielding device specific pump function graphs for water and pig blood. Our data demonstrate (i) flow sensitivity to preload and afterload and (ii) the effect of test fluid on hemodynamic performance.

Equipment Design↗

Assessing the performance of SPM analyses of spect neuroactivation studies. Statistical Parametric Mapping.

Several simulations of SPECT neuroactivation studies have been performed in order to determine the influence of both study size and activation focus characteristics on the detection of brain activation foci following a pixel-based statistical analysis. This was achieved by developing a methodology based on the Hoffman software brain phantom, SPECT acquisition simulation software, standard reconstruction software, and the Statistical Parametric Mapping (SPM96) package. We present results on the minimal activation levels required for focus detection. Furthermore, the improved sensitivity of the analysis resulting from the use of an iterative reconstruction technique (OSEM) with regard to the classical filtered backprojection (FBP) is assessed quantitatively, and the various physical, processing, and physiological parameters that potentially influence the detection of foci are discussed. Finally, the influence is investigated of the height threshold as implemented in SPM96 upon the size of the detected foci. Practical guidelines are proposed with regard to the number of subjects per group for SPECT activation studies following the split-dose design.

Brain↗

PACS and multimodality in medical imaging.

A PACS (Picture Archiving and Communication System) is a system that is able to store, exchange, display and manipulate images and associated diagnoses from any modality within a hospital in a timely and cost-effective way. Several developments, such as the DICOM standard, fast and convenient networking, and new storage solutions for large amounts of data, make the setup of such a PACS system possible. As the information acquired with various imaging modalities is then available and often complementary, it is desirable for the clinician to have a point-by-point spatial co-registration of images from different modalities in order to enable a synergistic use of the multimodality imaging of a patient for increased diagnostic accuracy. Various types of algorithms are available for the matching of medical images from the same or from different modalities. Co-registration algorithms based on voxel properties consist of a similarity or dissimilarity measure and an iterative or non-iterative method minimizing the dissimilarity or maximizing the similarity between the two images by a transformation of one image relative to the other.

Belgium↗

MRI guided segmentation and quantification of SPECT images of the basal ganglia: a phantom study.

Due to the limited resolution of single-photon emission computed tomography (SPECT) imaging devices, tissue interfaces are not well defined in the reconstructed image, even though resolution recovery techniques may be used during reconstruction. Therefore, segmentation of a particular region and quantification of the tracer uptake in that region is critical due to spillover effects, when based on the SPECT image only. In this study, we present two methods for quantification of tracer uptake in a SPECT image, defined by a matched high resolution structural magnetic resonance image. We show preliminary results of both techniques, when applied for quantifying regional uptake in the different compartments of a phantom simulating the basal ganglia. These results indicate that the quantification method, which takes into account the blurring by the SPECT imaging device, promises to be perform better in the presence of background activity.

Basal Ganglia↗

PET imaging using gamma cameras.

This paper will review the recent advances and future developments in the field of coincidence imaging of positron emitters with a conventional Anger-type gamma camera. FDG imaging has shown high clinical importance in cardiology, neurology and especially oncology. Since access to full ring PET is mainly limited to university hospitals, there have been new developments allowing PET imaging on the standard Anger gamma camera. First the principles of coincidence imaging on a gamma camera will be reviewed. We will discuss the limitations of this technique, and the techniques used to partly overcome these limitations. The different configurations of the gamma camera operating in coincidence mode are pointed out. Different corrections for image degrading effects and reconstruction methods are evaluated in the final part.

Calibration↗

Iterative reconstruction algorithms in nuclear medicine.

Iterative reconstruction algorithms produce accurate images without streak artifacts as in filtered backprojection. They allow improved incorporation of important corrections for image degrading effects, such as attenuation, scatter and depth-dependent resolution. Only some corrections, which are important for accurate reconstruction in positron emission tomography and single photon emission computed tomography, can be applied to the data before filtered backprojection. The main limitation for introducing iterative algorithms in nuclear medicine has been computation time, which is much longer for iterative techniques than for filtered backprojection. Modern algorithms make use of acceleration techniques to speed up the reconstruction. These acceleration techniques and the development in computer processors have introduced iterative reconstruction in daily nuclear medicine routine. We give an overview of the most important iterative techniques and discuss the different corrections that can be incorporated to improve the image quality.

Algorithms↗

Image-correction techniques in SPECT.

This overview takes a look at different correction techniques for Single Photon Emission Computed Tomography (SPECT). We discuss the influence of the detection system followed by the scatter and attenuation caused by the object of investigation. When possible we describe how the correction methods for the different physical effects can be incorporated in the reconstruction method, being either filtered backprojection or iterative reconstruction.

Algorithms↗

Coincidence camera FDG imaging for the diagnosis of chronic orthopedic infections: a feasibility study.

PURPOSE: Results of dedicated [(18)F]fluoro-2-deoxy-d-glucose (FDG) PET imaging in patients with suspected orthopedic infections are promising. This study evaluates the feasibility of dual-head gamma-camera coincidence (DHC) imaging in this population. METHOD: Twenty-four patients, referred for the confirmation or exclusion of orthopedic infection, were prospectively studied with consecutive FDG-dedicated PET and FDG DHC imaging. Images were read by two blinded readers experienced with FDG PET and compared with the final diagnosis, obtained by microbiologic proof in 11 patients and clinical follow-up of at least 9 months in 13 patients. RESULTS: Nine patients had osseous infection on final diagnosis. Sensitivity, specificity, and accuracy in this limited series were (Reader 1/Reader 2), respectively, 100/100, 86/86, and 92/92% for FDG-dedicated PET and 89/89, 100/93, and 96/92% for FDG DHC imaging. CONCLUSION: Despite lower image quality for FDG DHC imaging, results in this limited series were comparable with the results of FDG-dedicated PET. Further studies are needed to confirm the utility of FDG DHC imaging in suspected chronic orthopedic infections in larger patient groups.