IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry. International Atomic Energy Agency/World Health Organization.

Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO), has performed postal TLD audits to verify calibration of radiotherapy beams in developing countries. The TLD programme also monitors activities of Secondary Standard Dosimetry Laboratories (SSDLs). The programme has checked approximately 4000 clinical beams in over 1100 hospitals. and in many instances significant errors have been detected in the beam calibration. Subsequent follow-up actions help to resolve the discrepancies, thus preventing further mistreatment of patients. The audits for SSDLs check the implementation of the dosimetry protocol in order to assure proper dissemination of dosimetry standards to the end-users. The TLD audit results for SSDLs show good consistency in the basic dosimetry worldwide. New TLD procedures and equipment have recently been introduced by the IAEA that include a modified TLD calibration methodology and computerised tools for automation of dose calculation from TLD readings.

Austria↗

Proton dosimetry intercomparison based on the ICRU report 59 protocol.

BACKGROUND AND PURPOSE: A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors. MATERIALS AND METHODS: Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations. RESULTS: The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type. CONCLUSIONS: Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.

Algorithms↗

Proton beam output measurement with an extrapolation chamber.

A variable air-volume, parallel-plate extrapolation chamber forming an integral part of a polystyrene phantom was used in measurement of dose rate in a 250 MeV clinical proton beam. The sensitive air-volume of the extrapolation chamber is controlled through the movement of the chamber piston by means of a micrometer mounted on the phantom body. The relative displacement of the piston is monitored by a calibrated mechanical distance travel indicator. The proton beam dose rate determined with the uncalibrated extrapolation chamber was 5% lower than the dose rate determined with a calibrated Farmer-type thimble chamber at the same depth in the polystyrene phantom. Despite the current 5% discrepancy, uncalibrated extrapolation chambers may offer a simple and practical alternative to current techniques used in output measurements of proton beam machines.

Calibration↗

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration↗

Application of solid state detectors for dosimetry of therapeutic proton beams.

A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated in terms of absorbed dose in a 60Co beam. Absorbed doses to muscle in proton beams for ionization chambers were derived using the TG 20 charged particle protocol. Absorbed doses to muscle for solid state detectors were derived using absorbed dose proton beam quality correction factors. Differences between the derived doses for ionization chambers and solid state detectors were found to be within the uncertainties of measurements: 4.5% for ionization chambers and 5% for solid state detectors.

Cobalt Radioisotopes↗

Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy.

The suitability of a natural diamond detector with a special contact system for the measurement of relative dose distributions in selected radiotherapy applications was studied. The performance of the diamond detector was analysed by comparison with measurements using an ionization chamber and a silicon diode detector. The good stability, high response and good spatial resolution of the diamond detector were demonstrated by relative measurements in high-energy photon and electron beams and around the 137Cs source of an afterloading device. The application of the diamond detectors for relative as well as absolute dose measurements of beta ray ophthalmic applicators was also highlighted. It is concluded that the diamond with the special contact system is a suitable detector for relative dose measurements in a wide variety of applications, especially when high response and high spatial resolution are required.

Brachytherapy↗