PubMed Health⌕ Search

Biomedical subjects

S Verjee

Publications and source records attributed to S Verjee.

6 recordsLinked to original sources

Survey of the use and clinical effectiveness of HPA-1a/5b-negative platelet concentrates in proven or suspected platelet alloimmunization.

The optimal treatment of neonatal alloimmune thrombocytopenia (NAIT) is the transfusion of compatible donor platelets. The National Blood Service in England has established panels of "accredited" donors negative for human platelet antigens HPA-1a and HPA-5b, the most commonly implicated alloantigens. We have retrospectively surveyed the frequency of use and clinical effectiveness of donations collected over a 13-month period from the Oxford accredited panel. Ninety-five per cent of hyperconcentrated platelets (HPCs) collected were issued, all for intrauterine transfusion to fetuses at risk of NAIT due to the presence of maternal platelet alloantibodies and previously affected siblings. Thirty-one per cent of paediatric platelet concentrates (PPCs) collected were issued, of which 57% were used for cases of suspected NAIT. Fifty-four per cent of adult therapeutic doses collected were issued; 5% of these were used in cases of suspected NAIT or proven post-transfusion purpura (PTP). Good increments were seen in most NAIT cases transfused with HPCs or PPCs, and a moderate increment in the one PTP case. We conclude that the establishment of accredited panels is justified and enables delivery of a clinically effective treatment for NAIT. Increased use and cost-effectiveness could be achieved by the delivery of an educational programme to neonatal unit clinical staff to increase the awareness and appropriate treatment of NAIT.

Antigens, Human Platelet↗

Inadequacies in the postnatal management of fetomaternal alloimmune thrombocytopenia (FMAIT).

93 (31%) of the 301 Haematology Departments in the U.K. responded to a questionnaire about the postnatal management of fetomaternal alloimmune thrombocytopenia (FMAIT). The number of reported cases of FMAIT was less than half than that estimated from its known incidence, suggesting that the condition is under-recognized. There was a consensus that the optimal approach to postnatal management is to transfuse compatible platelets promptly. However, a number of problems in the delivery of treatment were identified, including an apparent lack of awareness of the potential seriousness of the condition amongst clinical staff, and the availability of HPA-1a negative platelets.

Antibody Specificity↗

Dosing recommendations for encainide.

The onset of antiarrhythmic action of encainide in patients with ventricular arrhythmias occurred within 3 hours after a single dose of 25 or 50 mg. No significant antiarrhythmic activity was noted after only 10 mg. After 14 days of daily dosing, both the 25- and 50-mg dose levels of encainide administered 3 times/day abolished or decreased ventricular arrhythmias in patients tested over a 24-hour period, whereas the 10-mg dose was ineffective. In 5 well-controlled studies involving 331 patients, encainide produced a dose-related decrease in the absolute number of ventricular arrhythmias as well as an increase in the percentage of responders (greater than 75% decrease in ventricular arrhythmias). Doses of 75 mg/day were required to obtain at least a 50% reduction in ventricular arrhythmias or 50% of patients responding or both. Three-times-a-day dosing was as effective as 4-times-a-day dosing. Further, doses greater than 200 mg/day gave little or no increase in incidence of efficacy. Important side effects were very low using doses of less than or equal to 150 mg/day and increased significantly at greater than or equal to 150 mg/day. It is recommended that encainide be initiated at 25 mg 3 times/day for 4 to 7 days, then carefully titrated upward, as needed, to 35 and 50 mg 3 times/day, respectively, every 4 to 7 days. If needed, 50 mg 4 times/day is an appropriate next dosage. Rapid dose escalation or doses greater than 200 mg are discouraged. Patients with severe life-threatening arrhythmias should receive encainide in a setting with cardiac monitoring and advanced life support systems.

Anilides↗

Evaluation of Cobe Trima for the collection of blood components with particular reference to the in vitro characteristics of the red cell and platelet concentrates and the clinical responses to transfusion.

This study evaluated Cobe Trima for donor and operational acceptability, the quality and storage stability of the blood components collected, and the clinical responses to transfusion. The study was carried out in 2 phases; phase 1 assessed the efficiency of red cells and platelet collection, and the characteristics of the components collected before and after storage. Phase 2 was an evaluation of operational issues and the in vitro characteristics of the red cells and platelet concentrates at the time of transfusion in respect to their cellular content, and leucocyte (interleukin IL-6 and IL-8) and platelet-derived (Rantes) cytokine levels. Cytokine levels were also measured in the donors before and after the collection procedure and in patients both before and after transfusion. The clinical responses to a small number of transfusions were assessed. The Cobe Trima was found to be straightforward to use by the operators, although additional operator training was required to manage occasional uncertainty with alarm messages. It was acceptable to the donors except for the occurrence of citrate reactions in 3/6 donors in phase 1; this problem persisted in phase 2 (6/15 donors), and needs to be addressed in the future. All blood components met UK product specifications apart from 2 platelet concentrates, 2 red cell concentrates, and one unit of FFP; the red cell and platelet concentrates had good storage characteristics. The 2 procedures, which resulted in low platelet yields, were due to occlusion of the plasma line; the method for installation of the harness has been subsequently modified to prevent this. 2 red cell concentrates showed haemolysis; the reason for this was not established. The Factor VIII level was satisfactory in plasma and the cellular content was low. The responses to 12 platelet transfusions were expected as in a group of haematology patients, and no immediate adverse effects were reported with any of the transfusions. Leucocyte-associated (IL-8 and IL-6) and platelet-associated (Rantes) cytokine levels were not elevated in donor samples taken before or after the collection procedure, or in the red cell and platelet concentrates at the time of issue. Pre- and post-transfusion IL-8 levels were raised in one patient with non-immune platelet refractoriness, and normal in 2 patients with excellent or almost satisfactory responses to platelet transfusions raising the question as whether IL-8 could be used as a laboratory marker for non-immune platelet refractoriness due to infection.

Blood Component Removal↗