PubMed Health⌕ Search

Biomedical subjects

S Vynckier

Publications and source records attributed to S Vynckier.

At least 19 recordsLinked to original sources

Comparison of dosimetry recommendations for clinical proton beams.

The formalism and data in the two most recent dosimetry recommendations for clinical proton beams, ICRU Report 59 and the forthcoming IAEA Code of Practice, are compared. Chamber calibrations in terms of air kerma and absorbed dose to water are considered, including five different cylindrical ionization chamber types commonly used in proton beam dosimetry. The methodology for both types of calibration for ionization chambers is described in ICRU Report 59. The procedure based on air kerma calibrations is compared with an alternative formalism based on IAEA Codes of Practice (TRS-277, TRS-381), modified for proton beams. The new IAEA Code of Practice is exclusively based on calibrations in terms of absorbed dose to water and a direct comparison with ICRU Report 59 recommendations is made. Common to the two formalisms are the fundamental quantities Wair and w(air) and their atmospheric conditions of applicability. The difference in the recommended values of the ratio w(air)/Wair (protons to 60Co) is as large as 2.3%. The use of Wair and w(air) values for dry air (IAEA) and for ambient air (ICRU) is a contribution to the discrepancy, and the ICRU usage is questioned. For air kerma based chamber calibrations, ICRU Report 59 does not take into account the effect of different compositions of the build-up cap and chamber wall on the calibration beam quality. For the chamber types included in the study, this introduces discrepancies of up to 1.1%. Combined with differences in the recommended basic data, discrepancies in absorbed dose determination in proton beams of up to 2.1% are found. For the absorbed dose to water based formalism, differences in the formalism, notably the omission of perturbation factors for 60Co in ICRU 59, and data yield discrepancies in calculated kQ factors, and in absorbed dose determinations, between -1.5% and +2.6%, depending on the chamber type and the proton beam quality.

Air↗

The physical basis for radiotherapy with neutrons.

Radiotherapy with neutrons requires a large quantity of physical information about neutrons and their interaction with matter. Primarily the absorbed dose at a reference point needs to be determined. For treatment planning the dose distribution in a phantom must be measured and algorithms for the simulation of the dose distribution in a patient must be available. As neutrons interact with matter in a more complicated way as high-energy photons and electrons commonly used in radiotherapy, biological effects based on microdosimetric data are used for treatment planning. This paper presents a brief summary of the neutron sources used in radiotherapy. The dosimetry of the clinical neutron beams is described. Special aspects of the treatment planning with fast neutrons are discussed. For further radiobiological interpretation the fundamentals of microdosimetry are described. Finally recent and future developments in the field of physics for neutron therapy are mentioned.

Humans↗

Fast 2D phantom dosimetry for scanning proton beams.

A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions. The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/1 s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities.

Brachytherapy↗

RBE variation as a function of depth in the 200-MeV proton beam produced at the National Accelerator Centre in Faure (South Africa).

BACKGROUND AND PURPOSE: Thorough knowledge of the RBE of clinical proton beams is indispensable for exploiting their full ballistic advantage. Therefore, the RBE of the 200-MeV clinical proton beam produced at the National Accelerator Centre of Faure (South Africa) was measured at different critical points of the depth-dose distribution. MATERIAL AND METHODS: RBEs were determined at the initial plateau of the unmodulated and modulated beam (depth in Perspex = 43.5 mm), and at the beginning, middle and end of a 7-cm spread-out Bragg peak (SOBP) (depths in Perspex = 144.5, 165.5 and 191.5 mm, respectively). The biological system was the regeneration of intestinal crypts in mice after irradiation with a single fraction. RESULTS: Using 60Co gamma-rays as the reference, the RBE values (for a gamma-dose of 14.38 Gy corresponding to 10 regenerated crypts) were found equal to 1.16 +/- 0.04, 1.10 +/- 0.03, 1.18 +/- 0.04, 1.12 +/- 0.03 and 1.23 +/- 0.03, respectively. At all depths, RBEs were found to increase slightly (about 4%) with decreasing dose, in the investigated dose range (12-17 Gy). No significant RBE variation with depth was observed, although RBEs in the SOBP were found to average a higher value (1.18 +/- 0.06) than in the entrance plateau (1.13 +/- 0.04). CONCLUSION: An RBE value slightly larger than the current value of 1.10 should be adopted for clinical application with a 200-MeV proton beam.

Animals↗

RBE variation between fast neutron beams as a function of energy. Intercomparison involving 7 neutrontherapy facilities.

In fast neutron therapy, the relative biological effectiveness (RBE) of a given beam varies to a large extent with the neutron energy spectrum. This spectrum depends primarily on the energy of the incident particles and on the nuclear reaction used for neutron production. However, it also depends on other factors which are specific to the local facility, eg, target, collimation system, etc. Therefore direct radiobiological intercomparisons are justified. The present paper reports the results of an intercomparison performed at seven neutrontherapy centres: Orléans, France (p(34)+Be), Riyadh, Saudi Arabia (p(26)+Be), Ghent, Belgium (d(14.5)+Be), Faure, South Africa (p(66)+Be), Detroit, USA (d(48)+Be), Nice, France (p(65)+Be) and Louvain-la-Neuve, Belgium (p(65)+Be). The selected radiobiological system was intestinal crypt regeneration in mice after single fraction irradiation. The observed RBE values (ref cobalt-60 gamma-rays) were 1.79 +/- 0.10, 1.84 +/- 0.07, 2.24 +/- 0.11, 1.55 +/- 0.04, 1.51 +/- 0.03, 1.50 +/- 0.04 and 1.52 +/- 0.04, respectively. When machine availability permitted, additional factors were studied: two vs one fraction (Ghent, Louvain-la-Neuve), dose rate (Detroit), influence of depth in phantom (Faure, Detroit, Nice, Louvain-la-Neuve). In addition, at Orléans and Ghent, RBEs were also determined for LD50 at 6 days after selective abdominal irradiation and were found to be equal to the RBEs for crypt regeneration. The radiobiological intercomparisons were always combined with direct dosimetric intercomparisons and, when possible in some centres, with microdosimetric investigations.

Abdomen↗

The Nice high-energy neutron facility: dosimetry intercomparisons.

Neutron dosimetry intercomparison studies have been undertaken at the Nice neutrontherapy facility with the staff at Louvain-la-Neuve which has had wide experience in both dosimetric and radiobiological intercomparisons. Tissue equivalent (TE) ionization chambers were first calibrated in 60Co beams and then exposed in the neutron beam at different depths in a water phantom; the largest difference observed in neutron beam measurements with all the chambers tested was 0.89%, and most of them agreed to within less than 0.5%. The gamma component at four depths was derived from measurements with Geiger-Müller counters; the results obtained with the two counters (Nice and Louvain-la-Neuve), expressed as a percentage of the total dose (neutron + gamma), agreed to within less than 0.03% and the value increased from 1.4 to 4.2% between 2 and 20 cm in depth.

Calibration↗

The multileaf collimator for fast neutron therapy at Louvain-la-Neuve.

The multileaf collimator of the fast neutron therapy facility at Louvain-la-Neuve is described, as well as some of the physics experiments performed in order to evaluate the attenuation of neutron beams in different materials and thus optimize the composition of the collimator leaves. The multileaf collimator consists of two sets of 22 leaves each, which can be moved independently. They are made of iron and their thickness is 95 cm. Seven borated polyethylene disks are located in the distal part of the leaves in order to absorb more efficiently the low-energy component of the neutron spectrum. The width of the leaves is 1 cm at their distal part. The leaves can move 11 cm outwards and 6 cm inwards from their reference position, and field sizes up to 25.7 x 24.8 cm, as well as irregular field shapes, can be obtained. The inner part of the leaves and their two sides are always focused on the target. The complete multileaf collimator can rotate around the beam axis, from -90 degrees to +90 degrees from the reference position. The width of the penumbra (80-20% isodoses) is 0.64 cm and 1.17 cm at the depth of the maximum buildup and at 10 cm in depth respectively, for a 10 x 10 cm field size. The collimator is adequate for the energy of the p(65)+Be neutron beam of Louvain-la-Neuve and has been adapted to the fixed vertical beam. It has been designed following the original plans of Scanditronix, adjusted and fully assembled at the workshop of the Centre de Recherches du Cyclotron (CRC). Systematic measurements were performed in order to optimize the design and the composition of the leaves. In particular the attenuations of the actual beam and of monoenergetic neutron beams were measured in different materials such as iron and polyethylene. Above (upstream) the multileaf collimator, a fixed pre-collimator (iron thickness 50 cm; section 1 x 1 m) defines a conical aperture aligned on the largest opening of the leaves. It contains the two transmission chambers and a 2 cm thick polyethylene layer used for hardening the beam.

Belgium↗

[Water calorimetry measurements in a 85 MeV clinical proton beam].

The importance of water calorimetry in clinical proton beam dosimetry has increased for various reasons: there has been an increasing interest in proton therapy from the radiotherapy world; existing dosimetry protocols for clinical proton beams recommend calorimetry as the primary dosimetry method (ie, AAPM and ECHED); water has recently become the reference material for dose specification. For the water calorimetric dose evaluation, the water calorimeter developed in Ghent was used. Ionometry was performed following the ECHED protocol. The study resulted in a calorimetric to ionometric dose ratio of 0.974 +/- 0.009. The discrepancy should in our opinion be attributed to the (Wle)p,air value of 35.2 J/C implemented in the protocol, possibly next to ion chamber dependent effects for which indications are found in the ionometry measurements.

Calorimetry↗

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration↗

Entrance and exit dose measurements with semiconductors and thermoluminescent dosemeters: a comparison of methods and in vivo results.

BACKGROUND AND PURPOSE: In order to compare diodes and TLD for in vivo dosimetry, systematic measurements of entrance and exit doses were performed with semiconductor detectors and thermoluminescent dosemeters for brain and head and neck patients treated isocentrically with external photon beam therapy. MATERIAL AND METHODS: Scanditronix EDP-20 diodes and 7LiF thermoluminescent chips, irradiated in a 8 MV linac, were studied with similar build-up cap geometries and materials in order to assure an equivalent electronic equilibrium. Identical calibration methodology was applied to both detectors for the dose determination in clinical conditions. RESULTS: For the entrance dose evaluation over 249 field measurements, the ratio of the measured dose to the expected dose, calculated from tabulated tissue maximum ratios, was equal to 1.010 +/- 0.028 (1 s.d.) from diodes and 1.013 +/- 0.041 from thermoluminescent crystals. For the exit dose measurements, these ratios were equal to 0.998 +/- 0.049 and 1.016 +/- 0.070 for diodes and TLDs, respectively, after application of a simple inhomogeneity correction to the calculation of the expected exit dose. CONCLUSIONS: Thermoluminescence and semiconductors led to identical results for entrance and exit dose evaluation but TLDs were characterised by a lower reproducibility inherent to the TL process itself and to the acquisition and annihilation procedures.

Brain Neoplasms↗

Response analysis of TLD-300 dosimeters in heavy-particle beams.

In vivo dosimetry is recommended as part of the quality control procedure for treatment verification in radiation therapy. Using thermoluminescence, such controls are planned in the p(65) + Be neutron and 85 MeV proton beams produced at the cyclotron at Louvain-La-Neuve and dedicated to therapy applications. A preliminary study of the peak 3 (150 degrees C) and peak 5 (250 degrees C) response of CaF2:Tm (TLD-300) to neutron and proton beams aimed to analyse the effect of different radiation qualities on the dosimetric behaviour of the detector irradiated in phantom. To broaden the range of investigation, the study was extended to an experimental 12C heavy ion beam (95 MeV/nucleon). The peak 3 and 5 sensitivities in the neutron beam, compared to 60Co, varied little with depth. A major change of peak 5 sensitivity was observed for samples positioned under five leaves of the multi-leaf collimator. While peak 3 sensitivity was constant with depth in the unmodulated proton beam, peak 5 sensitivity increased by 15%. Near the Bragg peak, peak 3 showed the highest decrease of sensitivity. In the modulated proton beam, the sensitivity values were not significantly smaller than those measured in the unmodulated beam far from the Bragg peak region. The ratio of the heights of peak 3 and peak 5 decreased by 70% from the 60Co reference radiation to the 12C heavy-ion beam. This parameter was strongly correlated with the change of radiation quality.

Carbon↗

Radioiodine treatment of thyroid carcinoma in patients on maintenance hemodialysis.

To deliver optimal radioiodine activity in hemodialyzed patients with thyroid carcinoma, the behavior of radioiodine was followed during six treatments. During hemodialysis, blood activity decreases with a half-life of 3.4 +/- 0.5, (1SD) h. The whole body dose was calculated from the total activity determined during 10 days after 131I administration. A reasonable strategy may consist in delivering 25% of the currently prescribed activity (925 MBq-25 mCi) and to perform the first dialysis session after 24 h to reduce total body irradiation.

Adult↗

Water calorimetry and ionization chamber dosimetry in an 85-MeV clinical proton beam.

In recent years, the increased use of proton beams for clinical purposes has enhanced the demand for accurate absolute dosimetry for protons. As calorimetry is the most direct way to establish the absorbed dose and because water has recently been accepted as standard material for this type of beam, the importance of water calorimetry is obvious. In this work we report water calorimeter operation in an 85-MeV proton beam and a comparison of the absorbed dose to water measured by ionometry with the dose resulting from water calorimetric measurements. To ensure a proper understanding of the heat defect for defined impurities in water for this type of radiation, a relative response study was first done in comparison with theoretical calculations of the heat defect. The results showed that pure hypoxic water and hydrogen-saturated water yielded the same response with practically zero heat defect, in agreement with the model calculations. The absorbed dose inferred from these measurements was then compared with the dose derived from ionometry by applying the European Charged Heavy Particle Dosimetry (ECHED) protocol. Restricting the comparison to chambers recommended in the protocol, the calorimeter dose was found to be 2.6% +/- 0.9% lower than the average ionometry dose. In order to estimate the significance of chamber-dependent effects in this deviation, measurements were performed using a set of ten ionization chambers of five different types. The maximum internal deviation in the ionometry results amounted to 1.1%. We detected no systematic chamber volume dependence, but observed a small but systematic effect of the chamber wall thickness. The observed deviation between calorimetry and ionometry can be attributed to a combination of the value of (Wair/e)p for protons, adopted in the ECHED protocol, the mass stopping power ratios of water to air for protons, and possibly small ionization chamber wall effects.

Calorimetry↗

Supplement to the code of practice for clinical proton dosimetry. ECHED (European Clinical Heavy Particle Dosimetry Group).

The 'Code of Practice for Clinical Proton Dosimetry' (Vynckier, S., Bonnett, D.E. and Jones, D.T.L. Code of practice for clinical proton dosimetry. Radiother. Oncol. 20: 53-63, 1991) was published in 1991, but since then new data for mass stopping powers have been reported and consideration has been given to the specification of absorbed dose in water instead of the original recommendation of absorbed dose in tissue. This supplement summarises the basic recommendations of the original Code of Practice and incorporates the new stopping power data for dose specification in water.

Absorption↗

Verification of absorbed doses determined with thimble and parallel-plate ionization chambers in clinical electron beams using ferrous sulphate dosimetry.

Absorbed dose values determined with the commonly applied NACP and PTW/Markus parallel-plate chambers and the cylindrical NE2571 Farmer chamber were compared to values obtained with ferrous sulphate dosimetry in a number of electron beams. For the ionometry with the parallel-plate chambers the dose-to-air chamber factor ND (or Ngas) was derived from a 60Co beam calibration free in air with an additional buildup layer of 0.54 g cm-2 graphite as proposed by the protocol for electron dosimetry published by the Netherlands Commission on Radiation Dosimetry. For the product kattkm in this calibration geometry values of 0.980 +/- 0.003 [1 standard deviation (s.d.)] and 0.993 +/- 0.004 (1 s.d.) were obtained for the parallel-plate NACP and PTW/Markus chambers, respectively. The behavior of the fluence perturbation correction factor pf versus the mean electron energy at depth was deduced for the flat PTW/Markus and cylindrical NE2571 chamber by comparison with the NACP chamber, for which pf was assumed unity. Our results show a small but significant energy dependence of pf for the PTW/Markus chamber. The absorbed dose values, determined ionometrically with the different chambers considered in the study using the experimentally determined kattkm and pf values, are systematically 0.5% higher than those obtained with ferrous sulphate dosimetry adopting 352 x 10(-6) m-2 kg-1 Gy-1 for epsilon mG. The performed comparative study confirms also that for the NACP chamber pf is unity independent of the electron energy down to a mean energy at depth of 2 MeV.

Biophysical Phenomena↗

Influence of cisplatinum on intestinal tolerance to photon and neutron irradiation in mice.

The hypothesis that cisplatinum (c-DDP) interacts with radiation by inhibiting the cellular repair capacities, was tested by comparing the interaction of c-DDP with low-LET (60Co gamma-rays) and high-LET radiation (d(50) + Be neutrons) in mice. The biological endpoint was lethality, 6 days after total body irradiation (early intestinal tolerance). The dose modifying factor was 1.80 +/- 0.25 for c-DDP plus 60Co gamma-rays, and 1.97 +/- 0.3 for c-DDP plus neutrons. As less repairable damage is induced by fast neutrons than by photons, this suggests that, in this system, the interaction between radiation and c-DDP is not explained by repair inhibition but is purely additive.

Animals↗

A dosimetric quality audit of photon beams by the Belgian Hospital Physicist Association.

Since 1987, a dosimetric standardization process has been started by the Belgian Hospital Physicist Association (BHPA). As part of this project, on-site visits were performed by a voluntary team, by request of the local physicist. They included mechanical checks on treatment machines and simulators and a dosimetric intercomparison of photon beams, following the EORTC methodology. Until now 16 centres have participated. Dose measurements were performed in order to evaluate the uniformity in dosimetry after the adoption by the BHPA members of the Nederlandse Commissie voor Stralingsdosimetrie (NCS) code of practice for photon beams. Doses were measured with an ionization chamber in water under NCS reference conditions and under other conditions in 13 cobalt beams and 24 high energy X-ray beams from 4 to 25 MV. Under reference conditions, the mean ratio of measured to stated dose is 0.999 (+/- 0.010) and 1.006 (+/- 0.23) for cobalt and X-ray beams, respectively, with a difference between the extreme values (delta) of 0.042 for cobalt beams and 0.084 for X-ray beams. In other conditions, the spread is a little larger for all beams. The results are comparable, but with a smaller dispersion, with those of other national and international similar dose intercomparisons and show the importance of applying a common protocol. The results of mechanical checks show some large deviations in digital displays and indicate the need for a systematic mechanical and beam alignment quality assurance programme.

Belgium↗