PubMed Health⌕ Search

Biomedical subjects

S W Newsom

Publications and source records attributed to S W Newsom.

At least 19 recordsLinked to original sources

A randomised trial of the durability of non-allergenic latex-free surgical gloves versus latex gloves.

A prospective randomised trial was performed to compare the robustness of a new non-latex surgical glove with a standard latex glove when worn by four general surgeons in a district general hospital. Gloves were retrieved after surgery and examined using the European Standard Test for punctures. The overall puncture rate was 10.1%, and there was no significant difference in the rates between the two types of glove, although punctures in the non-latex glove tended to be larger and more readily noted by the wearer. The increase in latex allergy among health care staff dictates the need for gloves made from other materials, which may also be useful for operations on latex-allergic patients.

Attitude of Health Personnel↗

A survey of starch particle counts in the hospital environment in relation to the use of powdered latex gloves.

As latex proteins, which cause latex hypersensitivity, can be found on starch particles and inhalation may be a route for sensitization, the presence of starch particles in hospital air was examined. The starch particles were demonstrated by immobilization onto cellulose acetate filters and staining with iodine. Rooms in which powdered latex gloves were used gave counts of up to > 3,667 particles per cubic meter of air. Starch particles were not found in the air in rooms where latex gloves were not used, and were highest in rooms with a high glove usage but no ventilation. A change to powder-free gloves significantly reduced the count of starch particles in the unventilated Accident/Emergency Department air. Use of powder-free gloves should be considered especially in unventilated areas in healthcare premises.

Air Pollutants, Occupational↗

Airborne particles from latex gloves in the hospital environment.

Air sampling studies are described which show high levels of airborne starch powder contamination in areas where powdered latex gloves are used. Furthermore, culture of collected samples show a clear association between starch particles and bacterial colonies in an experimental system suggesting that airborne particles could act as a vector for pathogens in the hospital environment.

Air Microbiology↗

Penetration of meropenem into heart valve tissue.

Thirty-three patients requiring cardiac valve surgery were administered meropenem 1000 mg by a 5 to 10 min iv injection. Samples of blood, cardiac valve and atrial muscle tissue were removed at valvectomy and analysed for meropenem by high performance liquid chromatography (HPLC) with UV detection. The plasma concentrations observed in the samples from these patients were higher than those reported when meropenem 1000 mg was administered to healthy volunteers by 5 min iv injection. No clinical adverse events attributable to meropenem were reported and the single 1000 mg dose was well tolerated. The penetration of meropenem into cardiac muscle and valve tissue was rapid and in excess of that expected solely on the basis of distribution into extracellular fluid. The concentrations achieved in the tissues were in excess of the MICs of the pathogens commonly causing endocarditis.

Aortic Valve↗

Tests for the antibacterial activity of surgical glove material.

In-vitro and in-vivo models for testing the antibacterial activity of glove materials are described. The models were tested using four types of material: latex containing residual accelerator, latex treated by solvent-extraction to remove accelerator, material from hypo-allergenic accelerator-free gloves, and latex coated with quaternary ammonium compounds. In-vitro tests revealed two distinct types of antibacterial activity, one related to the accelerator which was slow-acting, and not neutralizable, and a second faster-acting neutralizable activity due to the quaternary ammonium compounds. The antiseptic coated material also showed antibacterial activity on human skin.

Anti-Bacterial Agents↗

The clinical use of an antibiotic-bonded graft.

Attempts to produce an antibiotic-bonded prosthesis have failed owing to poor binding, drug toxicity or inadequate antimicrobial activity of the antibiotic particularly against Staphylococcus epidermidis. Rifampicin, with an ideal spectrum, but untested against slime-forming S. epidermidis has recently been shown to bind with carboxyl groups on gelatin-sealed Dacron. We therefore investigated rifampicin activity against 30 slime-forming adherent S. epidermidis colonies, isolated from 40 consecutive aortic graft recipients, and compared it with their methicillin, gentamicin, cefuroxime, tetracycline and vancomycin resistance patterns. The S. epidermidis colonies were highly sensitive to very low levels of rifampicin. Rifampicin was then bonded to gelatin-sealed Dacron aortic prostheses which were inserted in four patients at high risk of developing subsequent infection.

Aged↗

Hygienic hand disinfection tests in three laboratories.

A comparative study was made in three laboratories of a test for hygienic hand disinfection. Staphylococcus aureus was applied to the fingertips of a total of 74 volunteers (49 female and 25 male) and the effect of washing with three chlorhexidine preparations and one non-medicated soap was assessed after one and five applications. Fingertip inoculation is convenient and is a realistic representation of the in-use situation. Although significant differences were obtained between log10 reductions in test organisms using the same formulation in different centres, and different periods in the same centre, the maximum differences after a single application of a preparation were small, e.g. between centres 0.39 and between periods in the same centre 0.55, and after multiple applications the maximum difference between centres was 0.42 and between periods in the same centre it was 0.51. The differences between preparations were similar in all centres. This test compares well with other similar tests and products can be placed in rank order of effectiveness. It is concluded that this test, if carried out under the controlled conditions described, is sufficiently reproducible between laboratories and repeatable within laboratories to be used as a standard test.

Chlorhexidine↗

In vitro activity of ramoplanin on staphylococci.

Approximately 1000 strains of staphylococci isolated from the skin of patients before and after coronary artery by-pass surgery were speciated using the API-Staph system, and tested for susceptibility to ramoplanin and teicoplanin. In addition flucloxacillin MICs were available for 750 strains. MICs were performed by incorporating dilutions of antibiotics in 'Isosensitest' Agar (Oxoid) and applying approx 10(4) cells by a multi-point inoculator. The strains tested (numbers in brackets) included: Staph. epidermidis (352), Staph. haemolyticus (133), Staph. simulans (104), Staph aureus (69), Staph. hominis (54), Staph. warneri (39), Staph. capitis (23), Staph. saprophyticus (12), Staph. cohnii (6) and Staph. sciuri (2). The overall MICs were: ramoplanin MIC 50%: 0.5 mg/l, MIC 90%: 1 mg/l; teicoplanin MIC 50%: 2 mg/l, MIC 90%: 8 mg/l. Ramoplanin MICs of greater than 2 mg/l were only found for 17 strains from eleven patients which included: Staph. simulans (6), Staph. haemolyticus (4) and Staph. epidermidis (2). The maximum MIC however was only 8 mgl, so no strains were ramoplanin-resistant. There was no relationship between ramoplanin and flucloxacillin MICs; but despite their differing modes of action, the strains with higher ramoplanin MICs also had higher teicoplanin MICs.

Anti-Bacterial Agents↗

Application of the hygienic hand-disinfection test to the gloved hand.

The Austrian Standard Hygienic Hand-Disinfection Test was adapted for comparing the effect of washing artificially contaminated hands (using Escherichia coli) with contaminated gloved hands, using liquid soap and rinsing with water. Tests showed that a single soap wash completely removed all the bacteria from the glove, and was more than 1000 times more effective on the glove than on the hand.

Escherichia coli↗

Penetration of enoxacin into lung tissue.

For a study of penetration of enoxacin into lung, patients undergoing pneumonectomy were given 400 mg by mouth the night before and again approx 2 h before operation. A blood sample was taken as the lung was excised. Lung and serum enoxacin concentrations were assayed by high pressure liquid chromatography. Results from 15 patients showed that enoxacin was concentrated in the lung. Enoxacin lung concentrations were 3.2-13.1 mg/l, and ratios of lung to serum concentrations were 3-6 (mean, 4.2).

Adult↗

Studies on perioperative skin flora.

Chlorhexidine in spirit is used to reduce the skin bacterial load before surgery; and recently prewashing with chlorhexidine scrub has been advocated. We describe three studies on cardio-thoracic surgical patients--particularly those having coronary artery grafts with long leg and sternal wounds. Two studies compared prewashes with chlorhexidine scrub (Hibiscrub-ICI) or soap. Study Number One (250 patients per group) was of wound infections; and Number Two (25 patients per group) was of alterations in skin flora for 10 days postoperation. Chlorhexidine scrub failed to reduce overall wound infection rates in Study 1, although leg wounds healed more quickly with less inflammation. Study Two showed that the scrub had a significant effect on skin flora that lasted at least 3 days postoperation. Study Number Three was of 100 patients (no chlorhexidine scrub) examined for methicillin-resistant coagulase-negative staphylococci (MRSE) by cultures of swabs from the leg, sternum and chest drain site before and after operation on methicillin agar. Three per cent of patients had MRSE preoperation (1 doctor) and 23% postoperation. One thousand strains were tested by agar dilution against methicillin and chlorhexidine. MRSE had a 2-8-fold increased resistance to chlorhexidine compared to a greater than 256-fold to methicillin. Thus although chlorhexidine has a marked persistent effect on skin flora, emergence of major resistance is unlikely. Use of postoperative chlorhexidine should be investigated further.

Bacteria↗

What is in the surgeon's glove?

Three aspects of surgical hand hygiene have been studied: the attitude of the surgeon, the microbiology of glove changing during an operation, and the use of antiseptic-coated gloves together with different handwash routines. The survey revealed that the predominant factor in choice of agent for surgical hand hygiene was skin tolerance. The microbiological studies showed that 'closed' glove changing was to be preferred to 'open' changing, and that antiseptic-coated gloves further suppressed the skin flora, even after prolonged operations, compared to standard gloves.

Anti-Infective Agents, Local↗