PubMed Health⌕ Search

Biomedical subjects

S W Wilkins

Publications and source records attributed to S W Wilkins.

12 recordsLinked to original sources

On qualitative and quantitative analysis in analyser-based imaging.

Using rigorous wave-optical formalism, a general expression is obtained for the image intensity distribution in combined analyser-based/propagation-based phase-contrast imaging. This expression takes into account partial coherence of the wave incident on the object as well as the finite resolution of the detector system. Using this general expression, two approaches based on the geometrical optics and weak-object approximations are applied to derive simple solutions to the inverse problem of reconstruction of the phase and amplitude of the object wave. With the help of numerical experiments, the two approaches are compared in terms of their validity conditions and are shown to impose certain restrictions on the properties of the object wave. In particular, it is shown that violation of the validity conditions of the geometrical optics or weak-object approximations results in the appearance of strong reconstruction artefacts in the transmitted intensity near the edges of the objects. The effect of the incident wavefront non-uniformity due to imperfections of the imaging set-up on image formation and phase/amplitude reconstruction is also discussed. A solution to this problem is proposed in the form of a multi-image phase/amplitude reconstruction algorithm based on the geometrical optics approximation. This algorithm and an algorithm based on the weak-object approximation are applied to simulated and experimental images of fibres.

Journal Article↗

Generalized eikonal of partially coherent beams and its use in quantitative imaging.

The generalized eikonal of a partially coherent paraxial wave is introduced via a differential equation describing the evolution of the time-averaged intensity. The theoretical formalism provides an analytical tool for the study of partially coherent imaging systems. It also makes possible quantitative phase retrieval and compositional mapping of weakly absorbing samples using phase-contrast imaging with broadband polychromatic radiation of known spectral distribution. An experimental demonstration is presented of the quantitative reconstruction of the projected thickness of a sample, given a phase-contrast image obtained using a polychromatic microfocus x-ray source.

Biophysics↗

X-ray omni microscopy.

The science of wave-field phase retrieval and phase measurement is sufficiently mature to permit the routine reconstruction, over a given plane, of the complex wave-function associated with certain coherent forward-propagating scalar wave-fields. This reconstruction gives total knowledge of the information that has been encoded in the complex wave-field by passage through a sample of interest. Such total knowledge is powerful, because it permits the emulation in software of the subsequent action of an infinite variety of coherent imaging systems. Such 'virtual optics', in which software forms a natural extension of the 'hardware optics' in an imaging system, may be useful in contexts such as quantitative atom and X-ray imaging, in which optical elements such as beam-splitters and lenses can be realized in software rather than optical hardware. Here, we develop the requisite theory to describe such hybrid virtual-physical imaging systems, which we term 'omni optics' because of their infinite flexibility. We then give an experimental demonstration of these ideas by showing that a lensless X-ray point projection microscope can, when equipped with the appropriate software, emulate an infinite variety of optical imaging systems including those which yield interferograms, Zernike phase contrast, Schlieren imaging and diffraction-enhanced imaging.

Animals↗

Quantitative analysis of two-component samples using in-line hard X-ray images.

Methods for rapid quantitative phase-sensitive X-ray imaging of non-crystalline samples consisting of two distinct components are investigated. The transverse spatial distribution of the projected thickness of each component is reconstructed by computer processing of in-line images collected using synchrotron-generated hard X-rays and a position-sensitive detector with submicrometre spatial resolution. Different imaging techniques and associated image-processing algorithms are considered, with relative advantages and difficulties of each approach compared. A possible generalization of the method for the case of n-component samples is briefly discussed.

Journal Article↗

Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object.

We demonstrate simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object. Subject to the assumptions explicitly stated in the derivation, the algorithm solves the twin-image problem of in-line holography and is capable of analysing data obtained using X-ray microscopy, electron microscopy, neutron microscopy or visible-light microscopy, especially as they relate to defocus and point projection methods. Our simple, robust, non-iterative and computationally efficient method is applied to data obtained using an X-ray phase contrast ultramicroscope.

Journal Article↗

Quantitative X-ray projection microscopy: phase-contrast and multi-spectral imaging.

We outline a new approach to X-ray projection microscopy in a scanning electron microscope (SEM), which exploits phase contrast to boost the quality and information content of images. These developments have been made possible by the combination of a high-brightness field-emission gun (FEG)-based SEM, direct detection CCD technology and new phase retrieval algorithms. Using this approach we have been able to obtain spatial resolution of < 0.2 micro m and have demonstrated novel features such as: (i) phase-contrast enhanced visibility of high spatial frequency image features (e.g. edges and boundaries) over a wide energy range; (ii) energy-resolved imaging to simultaneously produce multiple quasi-monochromatic images using broad-band polychromatic illumination; (iii) easy implementation of microtomography; (iv) rapid and robust phase/amplitude-retrieval algorithms to enable new real-time and quantitative modes of microscopic imaging. These algorithms can also be applied successfully to recover object-plane information from intermediate-field images, unlocking the potentially greater contrast and resolution of the intermediate-field regime. Widespread applications are envisaged for fields such as materials science, biological and biomedical research and microelectronics device inspection. Some illustrative examples are presented. The quantitative methods described here are also very relevant to projection microscopy using other sources of radiation, such as visible light and electrons.

Journal Article↗

Quantitative in-line phase-contrast imaging with multienergy X rays.

We present a new method for quantitative nondestructive characterization of objects by x-ray phase-contrast imaging. Spatial distributions of the projected values of the complex refractive index in the sample are reconstructed by processing near-field images collected at a fixed sample-to-detector distance using a polychromatic incident beam and an energy-sensitive area detector, such as a CCD used in the photon-counting spectroscopy mode. The method has the potential advantages of decreased radiation dose and increased accuracy compared to conventional techniques of x-ray imaging.

Journal Article↗

The role of radiographic phase-contrast imaging in the development of intracochlear electrode arrays.

OBJECTIVE: This study describes the application of a new radiographic imaging modality, phase-contrast radiography, to in vitro human temporal bone imaging and investigates its use in the development of new electrode arrays for cochlear implants. BACKGROUND: The development of perimodiolar electrode arrays for cochlear implants requires detailed information from postoperative radiologic assessment on the position of the array in relation to the cochlear structures. Current standard radiographic techniques provide only limited details. MATERIALS AND METHODS: Nucleus standard electrode arrays and perimodiolar Contour electrode arrays were implanted into the scala tympani of 11 human temporal bones. Both conventional and phase-contrast radiographs were taken of each temporal bone for comparative purposes. RESULTS: Phase-contrast imaging provides better visualization of anatomic details of the inner ear and of the structure of the intracochlear electrode array, and better definition of electrode location in relation to cochlear walls. CONCLUSION: Phase-contrast radiography offers significant improvement over conventional radiography in images of in vitro human temporal bones. It seems to be a valuable tool in the development of intracochlear electrode arrays and cochlear implant research. However, this new radiographic technique still requires certain computational and physics challenges to be addressed before its clinical use can be established.

Cochlea↗

Quantitative methods in phase-contrast x-ray imaging.

A new method for extracting quantitative information from phase-contrast x-ray images obtained with microfocus x-ray sources is presented. The proposed technique allows rapid noninvasive characterization of the internal structure of thick optically opaque organic samples. The method does not generally involve any sample preparation and does not need any x-ray optical elements (such as monochromators, zone plates, or interferometers). As a consequence, samples can be imaged in vivo or in vitro, and the images are free from optical aberrations. While alternative techniques of x-ray phase-contrast imaging usually require expensive synchrotron radiation sources, our method can be implemented with conventional, albeit microfocus, x-ray tubes, which greatly enhances its practicality. In the present work, we develop the theoretical framework, perform numerical simulations, and present the first experimental results, demonstrating the viability of the proposed approach. We believe that this method should find wide-ranging applications in clinical radiology and medical research.

Animals↗

Protein Crystal Diffraction Patterns Using a Capillary-Focused Synchrotron X-ray Beam.

A paraboloidally tapered glass monocapillary was used to focus an 8 keV monochromated synchrotron bending-magnet X-ray beam into a 40 (+/-5) mum focal spot located 45 (+/-5) mm from the exit of the capillary. This focal spot had a measured intensity gain of 120 (+/-10) times the intensity present in an equivalent cross section of the unfocused beam from the monochromator. This focused beam was used to obtain oscillation diffraction patterns on image plates from a hen egg-white lysozyme protein crystal in two distinct geometries: one with the specimen crystal at the capillary exit and the other with the crystal at the beam focus. In the first geometry, focused Bragg reflections were observed at the focal plane. In the second geometry, diverging Bragg reflections of high intensity from a small crystal volume were observed. Image-plate diffraction patterns for these two geometries were compared with exposures with equivalent integrated diffracted intensities obtained using a 100 x 100 mum unfocused X-ray beam with the same crystal. The use of the focused beam resulted in a reduction in the exposure time required to produce equivalent patterns by a factor of between 70 and 100.

Journal Article↗

Phase-contrast radiography.

For the past 100 years, the paradigm for radiography has been premised on absorption as the sole means of contrast formation and on ray optics as the basis for image interpretation. A new conceptual approach to radiography has been developed that includes phase (ie, refractive) contrast and requires wave optics for proper treatment. This new approach greatly increases the amount of information that can be obtained with radiographic techniques and is particularly well suited to the imaging of soft tissue and of very small features in biologic samples. A key feature of the present technique of phase-contrast radiography is the use of a microfocus x-ray source about an order of magnitude (< or = 20 microm) smaller than that used in conventional radiography. Phase-contrast radiography offers a number of improvements over conventional radiography in a clinical setting, especially in soft-tissue imaging. These improvements include increased contrast resulting in improved visualization of anatomic detail, reduced absorbed dose to the patient, inherent image magnification and high spatial resolution, use of harder x rays, and relative ease of implementation. More technologically advanced detectors are currently being developed and commercialized, which will help fully realize the considerable potential of phase-contrast imaging.

Animals↗