PubMed Health⌕ Search

Biomedical subjects

S W Wise

Publications and source records attributed to S W Wise.

At least 19 recordsLinked to original sources

Optimization of shaded surface display for CT angiography.

RATIONALE AND OBJECTIVES: The authors performed this study to determine the optimum threshold for performing computed tomographic (CT) angiography with shaded surface display (SSD). MATERIALS AND METHODS: A dedicated phantom was developed with an 8-mm luminal diameter. Each of 19 vessels had stenoses ranging from 0% to 93.8%. Five blinded, experienced reviewers separately measured each vessel by using SSD with display thresholds of 50, 100, 150, and 200 HU. RESULTS: For vessel diameters of 2 mm and larger, the best threshold value was 100 HU. This yielded measurements within 2% of the actual diameter and produced no false occlusions. For vessels 1 mm in diameter, the best threshold remained 100 HU, but this threshold was significantly less accurate than the standard (P = .0001) and produced two false occlusions in 15 vessels. For vessels 0.5 mm in diameter, the best threshold was 50 HU, although this still produced measurements significantly less accurate than the gold standard (P = .036) and one false occlusion in 15 vessels. CONCLUSION: CT angiography with SSD and an optimized threshold value is a useful technique in vessels 1 mm and larger.

Angiography↗

Comparative assessment of CT and sonographic techniques for appendiceal imaging.

OBJECTIVE: We performed a comparative assessment of CT and sonographic techniques used to assess appendicitis. MATERIALS AND METHODS: One hundred patients with clinically suspected acute appendicitis were examined with sonography, unenhanced focused appendiceal CT, complete abdominopelvic CT using IV contrast material, focused appendiceal CT with colonic contrast material, and repeated sonography with colonic contrast material. Each sonogram was videotaped for subsequent interpretation by three radiologists and two sonographers. The mean sensitivity, specificity, positive and negative predictive values, inter- and intraobserver variability, and diagnostic confidence scores of all observers were used for comparative performance assessments. The three CT examinations were filmed and interpreted separately by four radiologists. Patient discomfort was assessed on a 10-point scale for each radiologic study. Diagnoses were confirmed by pathologic evaluation of resected appendixes or clinical follow-up for a minimum of 3 months after presentation. RESULTS: Twenty-four of the 100 patients had positive findings for acute appendicitis. Both sonographic techniques had high specificity (85-89%) and comparable accuracy (73-75%) but low sensitivity (33-35%) and inter- and intraobserver variability (kappa = 0.15-0.20 and 0.39-0.42, respectively). Unenhanced focused appendiceal CT, abdominopelvic CT, and focused appendiceal CT with colonic contrast material all significantly outperformed sonography (p <0.0001), with sensitivities of 78%, 72%, and 80%; specificities of 86%, 91%, and 87%; and accuracies of 84%, 87%, and 85%, respectively. Abdominopelvic CT gave the greatest confidence in cases with negative findings (p = 0.001), and focused appendiceal CT with colonic contrast material gave the greatest confidence for cases with positive findings (p = 0.02). In terms of inter- and intraobserver variability, focused appendiceal CT with colonic contrast material yielded the highest, and unenhanced focused appendiceal CT the lowest, agreement (interobserver kappa = 0.45 vs. 0.36 and intraobserver kappa = 0.85 vs. 0.76, respectively) (p <0.05). Colonic contrast material was unsuccessfully advanced into the cecum in 18% of patients and leaked in another 24%. Patient discomfort was greatest with focused appendiceal CT using colonic contrast material and least with unenhanced focused appendiceal CT (p <0.05). CONCLUSION: A standard abdominopelvic CT scan is recommended as the initial examination for appendicitis in adult patients. However, focused appendiceal CT with colonic contrast material material should be used as a problem-solving technique in difficult cases.

Acute Disease↗

CT angiography: in vitro comparison of five reconstruction methods.

OBJECTIVE: Five image reconstruction techniques have been used with CT angiography: axial (cross-sectional), maximum intensity projection (MIP), curved multiplanar reconstruction (MPR), shaded-surface display, and volume rendering. This study used a phantom to compare the accuracy of these techniques for measuring stenosis. SUBJECTS AND METHODS: A 19-vessel phantom containing various grades of concentric stenoses (0-100%) and three lengths (5, 7.5, and 10 mm) of stenoses was used for this study. Scans were obtained with a slice thickness of 2.0 mm, slice interval of 1.0 mm, pitch of 1.0, 120 kVp, 200 mA, and with the vessels oriented parallel to the z-axis and opacified with nonionic contrast material. CT angiography images were produced using five optimized techniques: axial, MIP, MPR, shaded-surface display, and volume rendering; and measurements were made with an electronic cursor in the normal lumen and mid stenosis by five separate investigators who were unaware of vessel and stenosis diameters. Each of the techniques was first optimized according to the radiology literature and our own preliminary testing. RESULTS: For vessels greater than 4 mm in diameter, axial, MIP, MPR, shaded-surface display, and volume-rendering CT angiography techniques all had a measurement error of less than 2.5%. However, axial, MIP, MPR, and shaded-surface display techniques were less accurate in estimating smaller (<or=4 mm) diameters. Volume rendering tended to be more accurate in the measurement of vessels with a 2.0- to 4.0-mm diameter and was statistically more accurate for diameters of 0.5-1.0 mm (p < 0.001). CONCLUSION: All five CT angiography display techniques (axial, MIP, MPR, shaded-surface display, and volume rendering) accurately display vessels and stenoses greater than 4 mm in diameter. However, volume rendering tends to be more accurate for stenoses of 2-4 mm and was statistically better in the measurement of diameters of 0.5-1.0 mm (p < 0.001). Volume rendering is an accurate method for evaluating all grades of stenoses.

Angiography↗

Impact of the Armed Forces Institute of Pathology Radiologic Pathology Course on radiology resident performance on the ACR In-Training and ABR written Examinations. American College of Radiology. American Board of Radiology.

RATIONALE AND OBJECTIVES: The purpose of this study was to assess resident scores on the American College of Radiology (ACR) In-Training Examination and on the written American Board of Radiology (ABR) Examination relative to attendance at and timing of the Armed Forces Institute of Pathology (AFIP) Radiologic Pathology Course. MATERIALS AND METHODS: A survey of 200 radiology residency program directors requested the type of residency program, whether the program sent residents to the AFIP course, dates of AFIP attendance for individual residents, percentile scores of residents on the ACR examination from 1995 through 1998, and ABR examination scores for 1997. Scores were analyzed before and after AFIP attendance and also temporally for examinations during or after AFIP attendance. Improvement in percentile scores for residents undergoing the ACR examination while attending the AFIP were compared with scores of matched residents from their programs who had not attended. RESULTS: Thirty-six (18%) program directors responded, providing data on 619 residents who underwent the ACR examination, ABR examination, or both. No significant improvement was found between pre- and post-AFIP ACR Examination scores for residents at university or military programs. There were statistically significantly improved scores for residents at community programs (mean percentile improvement, 8.1 points; P = .0064). Residents who underwent the ACR examination during the AFIP course improved their scores by 10.7 percentile points compared with matched residents who had not attended the AFIP course (P = .041). CONCLUSION: Residents undergoing the ACR examination while attending the AFIP improve their percentile scores more than residents who have not attended the AFIP.

Curriculum↗

Mucosal detail at CT virtual reality: surface versus volume rendering.

PURPOSE: To evaluate computed tomographic virtual reality with volumetric versus surface rendering. MATERIALS AND METHODS: Virtual reality images were reconstructed for 27 normal or pathologic colonic, gastric, or bronchial structures in four ways: the transition zone (a) reconstructed separately from the wall by using volume rendering; (b) with attenuation equal to air; (c) with attenuation equal to wall (soft tissue); (d) with attenuation halfway between air and wall. The four reconstructed images were randomized. Four experienced imagers blinded to the reconstruction graded them from best to worst with predetermined criteria. RESULTS: All readers rated images with the transition zone as a separate structure as overwhelmingly superior (P <.001): Nineteen cases had complete concurrence among all readers. The best of the surface-rendering reconstructions had the transition zone attenuation equal to the wall attenuation (P <.001). The third best reconstruction had the transition zone attenuation equal to the air attenuation, and the worst had the transition zone attenuation halfway between the air and wall attenuation. CONCLUSION: Virtual reality is best with volume rendering, with the transition zone (mucosa) between the wall and air reconstructed as a separate structure.

Animals↗

CT bronchoscopy: optimization of imaging parameters.

The authors evaluated the relative importance of the following scanning parameters at computed tomographic bronchoscopy in an anesthetized adult sheep's thorax: section thickness (2, 4, 8 mm), pitch (1.0, 1.5, 2.0), milliampere setting (100, 175, 250 mA), and overlap of reconstructed sections (0%, 25%, 50%, 75%). Five blinded readers ranked the images twice in comparison with photographs of the mounted specimen. Differences in image quality were significant (P < .001) with section thickness of 2 mm and a pitch of 1.0. The milliampere setting had only a minor effect on image quality, and a 50% overlap of reconstructed sections was best.

Animals↗

Measuring carotid artery stenosis using CT angiography: the dilemma of artifactual lumen eccentricity.

OBJECTIVE: This study assesses artifactual luminal distortion, or eccentricity, that affects measurement of stenosis on CT angiography performed with a variety of helical protocols. MATERIALS AND METHODS: A 32-vessel carotid artery phantom was built with five known grades of stenoses (25%, 50%, 75%, 88%, and 94%) and three lengths of stenosis (1, 3, and 5 mm). This phantom was scanned with conventional and 1.0-, 1.5-, and 2.0-pitch helical CT with slice thicknesses of 2, 4, and 8 mm, and three vessel orientations: parallel, 45 degrees oblique, and perpendicular to the z-axis. Oblique multiplanar reconstruction was performed with the latter two vessel orientations to produce images similar to the parallel to z-axis orientation. The cross-sectional images were then used to measure the maximum and minimum (longest and shortest) luminal diameters in and out of each stenosis at a computer workstation by a single investigator who was unaware of the scanning technique. Percentage of stenosis was assessed by three methods: cross-sectional area in and out of the stenosis, maximum diameter out of stenosis and minimum in stenosis (North American Symptomatic Carotid Endarterectomy Trial method), and minimum diameter in and out of the stenosis. Comparisons were made with the gold standard using the equation (measured percentage of stenosis-actual percentage of stenosis) based on known luminal diameters of the phantom. Luminal eccentricity was assessed for each of the vessels and scanning parameters as a ratio of minimum to maximum diameters. RESULTS: All three methods of measuring stenoses were strongly affected by luminal eccentricity. The North American Symptomatic Carotid Endarterectomy Trial method overestimated percentage of stenosis an average of 1.64%. The most accurate results were obtained when using the minimum diameter in and out of the stenoses (-0.45% from the gold standard). Eccentricity was significantly greater in stenoses than in normal lumen (p < .0001) and when the vessels were oriented perpendicular to the z-axis (p = .0003). A progressive increase in eccentricity was seen in the 4- and 8-mm slice thicknesses and the 3- and 5-mm-long stenoses (p < .001; p < .001). CONCLUSION: Artifactual luminal eccentricity has significant implications for measuring percentage of stenosis revealed by CT angiography. Eccentricity increases in longer stenoses, thicker slices, and vessels oriented perpendicular to the z-axis. With CT angiography, measurement of minimum diameters in and out of a stenosis provides the most accurate assessment of percentage of stenosis.

Artifacts↗

The clinical usefulness of routine stacked multiplanar reconstruction in helical abdominal computed tomography.

RATIONALE AND OBJECTIVES: The authors evaluate the usefulness of stacked multiplanar reconstructions in routine, thick-section abdominal computed tomography. MATERIALS AND METHODS: Twenty-five routine, thick-section contrast abdominal CTs performed with equivalent technique were reformatted by multiplanar reconstructions in sagittal and coronal planes sequentially from side-to-side and front-to-back. The image sets were submitted, first axial images only followed by axial plus multiplanar reconstructions (MPRs), to 5 separate physician readers including 2 radiologists and 3 nonradiologists. These readers graded the visualization of a variety of normal and up to 5 pathologic lesions per patient on a scale of 1 to 5 (5 = best). RESULTS: The addition of sagittal and coronal multiplanar reconstructions significantly improved the visualization of all normal anatomic structures (mean axial only, 3.8; mean axial plus MPR, 4.1; P < 0.0001). In addition, most pathologic lesions were statistically better visualized with the addition of multiplanar reconstructions (mean axial images only, 3.9; mean axial plus MPR, 4.1; P < 0.0001). All five readers found improved visualization in nearly every category with the addition of the multiplanar reconstructions. However, in only 7% of cases, did a reviewer find new diagnostic information with the addition of MPR images. CONCLUSIONS: Stacked multiplanar reconstructions of routine, thick-section abdominal CT has clinical value in both the display of normal anatomic and pathologic lesions. Further studies, however, are required to confirm these findings before it is commonly used.

Humans↗

Evaluation of contrast densities in the diagnosis of carotid stenosis by CT angiography.

OBJECTIVE: This study assesses intravascular density produced by ionic and nonionic contrast material and its effect on visualization of stenoses by CT angiography. MATERIALS AND METHODS: CT angiography was performed using a 32-vessel phantom to study grades of luminal stenoses (0-100%), three lengths of stenoses (1, 3, and 5 mm), and two angles of inclination into the stenoses (45 degrees and 75 degrees). Scans were obtained with a slice thickness of 2 mm, a slice interval of 1.5 mm, a pitch of 1.0, a voltage of 120 kV, and a current of both 100 and 200 mA. Vessels were oriented parallel to the z-axis, and opacified with ionic and nonionic contrast material that had densities of 100, 150, 200, 250, 300, and 350 H. Cross-sectional luminal diameters were measured in and out of the stenoses. Edge definition and halo artifact for each vessel were graded by an investigator who was unaware of the contrast material density used. RESULTS: A contrast density of 150 H as revealed by CT angiography yielded the most accurate stenosis measurements with ionic contrast material. For nonionic contrast material, attenuation values of 150 and 200 H produced the best results on CT angiography. A density of 100 H or greater than 250 H significantly increased the error of vessel measurement (p = .001) for both types of contrast material. For the two current levels tested (100 and 200 mA), no statistical difference was found. CONCLUSION: The accuracy of CT angiography in measuring carotid stenosis depends on the luminal attenuation value. An optimum contrast density is 150 H for ionic contrast material; for nonionic contrast material, 150-200 H (at the window and level settings of 300 H and 40 H).

Carotid Arteries↗

Technical factors of CT angiography studied with a carotid artery phantom.

PURPOSE: To evaluate scanning parameters (conventional versus spiral CT, section thickness, and pitch) and vessel orientation in the performance of CT angiography. METHODS: Conventional CT and 1.0-, 1.5-, and 2.0-pitch spiral CT acquisitions of a carotid phantom designed with vessels oriented parallel to the z-axis, 45 degrees oblique, and perpendicular to the z-axis were obtained with section thicknesses of 2, 4, and 8 mm. The phantom contained 32 vessels with 0% to 100% stenoses. Normal and stenotic luminal diameters were measured and the number of artifacts was assessed. RESULTS: No overall difference was observed among conventional and spiral CT acquisitions obtained with pitches of 1.0, 1.5, and 2.0. With thicker sections, CT angiographic accuracy decreased and artifacts increased. The three-vessel orientations were relatively comparable in accuracy in terms of the percentage of stenosis measured. Vessels parallel to the z-axis suffered less artifactual degradation. Unique artifacts, such as luminal distortion and beam hardening, were observed in vessels oriented at 45 degrees and perpendicular to the z-axis. CONCLUSION: Use of thinner sections with vessels oriented parallel to the z-axis optimizes CT angiographic quality. There is no apparent degradation with the use of spiral CT, and a pitch of 1.5 or 2.0 provides results equivalent to 1.0-pitch spiral studies.

Brain Ischemia↗

Abrupt climate change and transient climates during the Paleogene: a marine perspective.

Detailed investigations of high latitude sequences recently collected by the Ocean Drilling Program (ODP) indicate that periods of rapid climate change often culminated in brief transient climates, with more extreme conditions than subsequent long term climates. Two examples of such events have been identified in the Paleogene; the first in latest Paleocene time in the middle of a warming trend that began several million years earlier: the second in earliest Oligocene time near the end of a Middle Eocene to Late Oligocene global cooling trend. Superimposed on the earlier event was a sudden and extreme warming of both high latitude sea surface and deep ocean waters. Imbedded in the latter transition was an abrupt decline in high latitude temperatures and the brief appearance of a full size continental ice-sheet on Antarctica. In both cases the climate extremes were not stable, lasting for less than a few hundred thousand years, indicating a temporary or transient climate state. Geochemical and sedimentological evidence suggest that both Paleogene climate events were accompanied by reorganizations in ocean circulation, and major perturbations in marine productivity and the global carbon cycle. The Paleocene-Eocene thermal maximum was marked by reduced oceanic turnover and decreases in global delta 13C and in marine productivity, while the Early Oligocene glacial maximum was accompanied by intensification of deep ocean circulation and elevated delta 13C and productivity. It has been suggested that sudden changes in climate and/or ocean circulation might occur as a result of gradual forcing as certain physical thresholds are exceeded. We investigate the possibility that sudden reorganizations in ocean and/or atmosphere circulation during these abrupt transitions generated short-term positive feedbacks that briefly sustained these transient climatic states.

Animals↗

Sonographic incidence of deep venous thrombosis contralateral to hip or knee replacement surgery.

PURPOSE: This study assesses the sonographic incidence of deep venous thrombosis (DVT) contralateral to and the venographic incidence ipsilateral to hip or knee replacement surgery and the role of sonography in routine surveillance. METHODS: We prospectively evaluated 178 consecutive patients with sonography of the femoropopliteal venous systems of the contralateral lower extremity and venography of the ipsilateral lower extremity on days 3 and 4, respectively, after total hip or knee replacement surgery. RESULTS: No cases of acute DVT and only 1 case of chronic DVT isolated to the popliteal system were identified by sonography in the contralateral extremity. In the ipsilateral extremity, venography identified 26 patients with acute DVT (3 femoropopliteal, 21 calf, and 2 concurrent femoropopliteal and calf). CONCLUSIONS: Routine sonographic evaluation of the lower extremity contralateral to hip or knee replacement surgery is not cost-effective because of the extremely low incidence of detectable acute thrombus.

Adult↗

Enhancing ascites: an aid to CT diagnosis.

Enhancement of ascitic fluid on delayed contrast-enhanced CT has been described as a potential pitfall in diagnosis. We present a case in which the phenomenon was beneficial to diagnosis. Enhancement of ascites was useful in delineating the entire extent of a cystic pelvic mass. We also discuss probable molecular and histologic mechanisms responsible for this unique type of enhancement.

Adult↗

Renal medullary cystic disease: assessment by MRI.

Medullary cystic disease is an important cause of renal failure in adolescent patients. Imaging plays a primary role in the diagnosis of this entity as cysts are characteristically seen in the renal medulla and corticomedullary junction with normal to small sized kidneys. Imaging studies that do not use intravenous contrast or ionizing radiation are particularly useful given the young age of these patients and presence of renal failure. In this case, we demonstrate the imaging findings of medullary cystic disease by MRI.

Adult↗