PubMed Health⌕ Search

Biomedical subjects

S W Yusuf

Publications and source records attributed to S W Yusuf.

At least 19 recordsLinked to original sources

Endovascular repair of a recurrent aortocaval fistula and anastamotic false aneurysm.

Aortocaval fistula (ACF) and false aneurysm are a recognized complication of open abdominal aortic aneurysm (AAA) repair. Untreated they are often fatal. However, open surgical repair of this complication is associated with a high operative mortality and a significant complication rate. Endovascular management using a stent-graft to exclude the false aneurysm and fistula is a technically feasible alternative and confers many advantages over open repair by virtue of its minimally invasive nature. We report the endovascular management of this rare but serious complication of open AAA repair.

Aged↗

Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European Multicenter Experience.

AIM: The aim of this paper was to report the results of a multicenter study on endovascular repair of abdominal aortic aneurysms (AAA) in patients with important angulation of proximal neck using a flexible stent-graft (Aorfix). METHODS: Endovascular repair of AAA using a flexible stent-graft was performed at 16 centers in 29 patients with angulation of proximal neck greater than 45 degrees. Twenty-three patients (79%) had angulation greater than 60 degrees and were therefore contraindicated for repair with other contemporary devices. RESULTS: Technical success was achieved in all but one case (96%). There was one postoperative death due to multiorgan failure following revision of groin wound for hemorrhage. No patients were converted to open repair. One patient had persisting proximal endoleak despite placement of proximal extension. One patient in whom wireform fractures had been detected died from ruptured aneurysm at nearly 4 year follow-up. CONCLUSION: Endovascular repair using a flexible stent-graft is feasible in patients with highly angulated necks. This stent-graft allows the possibility of a to offer repair for patients un-suitable for the currently available commercial grafts. Mid-term results are acceptable and need to be confirmed by longer follow-up and larger series.

Aged↗

True juxta-anastomotic aneurysms in the residual infra-renal abdominal aorta.

INTRODUCTION: abdominal aortic dilatation can occur above the graft following repair of infra-renal abdominal aortic aneurysm (AAA). This study aimed to determine the incidence and possible aetiological associations of recurrent juxta-anastomotic aneurysms following open repair of AAA. METHODS: the diameter of the infra-renal aorta above the graft of 135 patients who had previously undergone open AAA repair was determined using ultrasound. In those where the diameter was greater than 40 mm a CT scan was undertaken. Co-morbid and operative details were determined from the patients and their clinical notes. RESULTS: seven patients had true juxta-anastomotic aneurysms (>40 mm) in the residual infra-renal abdominal aorta, the occurrence of which was associated with tobacco smoking and hypertension. There was no association with other co-morbid factors, surgical operative details or the development of iliac aneurysms (which occurred in 3% of patients). CONCLUSIONS: true juxta-anastomotic aneurysms develop in the residual infra-renal neck of patients following open repair of abdominal aortic aneurysm. Tobacco smoking and hypertension are significant factors associated with the development of these aneurysms. This group of patients may warrant surveillance to prevent aneurysm rupture.

Aged↗

Risk assessment of slow or no-reflow phenomenon in aortocoronary vein graft percutaneous intervention.

Slow or no-reflow phenomenon (SNR) complicates 10%-15% of cases of percutaneous intervention (PCI) in aortocoronary saphenous vein grafts (SVG). At present, there are no uniform, effective strategies to predict or prevent this common and potentially serious complication. The purpose of our study was to characterize variables correlated with the risk of SNR in SVG PCI in the era of stenting and glycoprotein IIb/IIIa receptor inhibitors. We identified 2,898 consecutive patients who had PCI, of whom 163 underwent PCI of at least one SVG. The clinical and angiographic characteristics of patients who developed SNR (SNR group) were compared with those who did not (no-SNR group). A total of 23 patients experienced SNR and 140 did not. Using a stepwise multivariate logistic regression analysis, four independent predictors for SNR were detected: probable thrombus (OR 6.9; 95% CI, 2.1-23.9; P = 0.001), acute coronary syndromes (OR 6.4; 95% CI, 2.0-25.3; P = 0.003), degenerated vein graft (OR 5.2; 95% CI, 1.7-16.6; P = 0.003), and ulcer (OR 3.4; 95% CI, 0.99-11.6; P = 0.04). The risk of developing SNR could be estimated according to the number of predictors found: low-grade risk (1%-10%) if < or = one variable was present, moderate risk (20%-40%) if two variables were present, and high risk (60%-90%) if three or more variables were present. We identified and quantified current risk factors for SNR and concluded that the risk of developing SNR during PCI in SVG can be predicted by simple clinical and angiographic variables obtained before PCI. This information may be useful when the risk of PCI has to be balanced against alternative strategies such as medical therapy or redo-bypass surgery or in the selection of those patients that will most benefit from the use of protection devices during PCI.

Aged↗

Pathophysiology of proximal perigraft endoleak following endovascular repair of abdominal aortic aneurysms: a study using a flow model.

OBJECTIVE: to design a flow model to determine whether and why increased proximal neck angulation correlates with increased risk of proximal perigraft endoleak (PPE) flow. METHODS: a tapered stent-graft (Gianturco stent + Dacron) was deployed with proximal and distal necks made of silicone. The amount of PPE was measured over 30-s periods while the angulation of the proximal neck was increased. RESULTS: PPE flow increased significantly for angulations > or =30 degrees. The graft was lifted off the neck wall and gaps between the stent-graft and the neck created. CONCLUSION: greater neck angulation increased PPE flow. The stent-graft was lifted off the neck and subsequent gaps created. This model could be used to compare available stent-grafts and to test new designs that would improve the seal in angulated necks.

Anastomosis, Surgical↗

Endovascular repair of ruptured abdominal aortic aneurysm--a challenge to open repair? Results of a single centre experience in 20 patients.

INTRODUCTION: The mortality from ruptured abdominal aortic aneurysm (AAA) remains in the region of 50% despite advances in critical care. Endovascular repair of AAA has been shown to be associated with reduced physiological stress in the elective setting. It is hypothesised that the reduced physiological stress associated with EVAR may improve the outcome in patients with ruptured AAA. METHODS: A feasibility study of endovascular repair of ruptured AAA was undertaken at the University Hospital, Nottingham, U.K. between 1994 and 2000. Patients admitted with ruptured AAA were assessed by a team familiar with endovascular techniques for elective repair of AAA. After giving informed consent patients underwent spiral computed tomographic angiography (CTA) in the majority of cases. Patients were then transferred to the operating theatre for EVAR. RESULTS: Twenty patients underwent repair of ruptured AAA. Of these 20 patients, seven were referred from another hospital. Eight patients were considered unfit for open repair. The median duration of procedure was 180 min (range 120-480) and median blood loss was 1200 ml (range 750-2000 ml). The overall peri-operative mortality was 45%. A number of intra-operative and peri-operative procedures (both open and endovascular) were required to ensure aneurysm exclusion and to deal with the complications of endovascular surgery. CONCLUSIONS: Ruptured AAA remains a particularly hazardous condition to treat. There are a number of advantages of EVAR in this condition. A number of the problems early in the experience of EVAR have been addressed, but further experience is required to demonstrate its efficacy when compared with open repair.

Aged↗

Intrarenal color duplex examination of aortic endograft patients with suprarenal stents.

PURPOSE: To report an experience using intrarenal color duplex ultrasonography (ICDU) to detect high-grade renal artery stenosis in patients who had endovascular repair of abdominal aortic aneurysm (AAA) with suprarenal stent fixation. METHODS: Twenty-eight patients (25 men; mean age 71 years, range 58-83) who had endovascular AAA repair with suprarenal stenting at least 3 months prior to commencement of this study were screened with ICDU. Acceleration time (AT), peak systolic velocity (PSV), end diastolic velocity (EDV), and resistive index (RI) were measured. The Doppler waveform was quantitatively scored on a scale from 0 to 4. AT >0.07 seconds, RI <0.45, or a Doppler waveform score of 0 or 1 (indicating loss of early systolic peak) were indicative of high-grade renal artery stenosis. RESULTS: Median follow-up was 15.5 months (range 3-34). ICDU was successful in 54 (98%) of 55 kidneys scanned. No AT values exceeded 0.07 seconds, all RIs were >0.45, and no waveforms had loss of early systolic peak, indicating that no patient had evidence of high-grade renal artery stenosis. CONCLUSIONS: ICDU is a simple and affordable method that seems well suited to periodic screening in patients with suprarenal stents. Longer follow-up with a larger number of patients is needed before definite conclusions can be drawn about the effect of suprarenal stenting on renal circulation.

Aged↗

Health care for sale.

Explore the source record for details and available documents.

Appointments and Schedules↗

Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms.

INTRODUCTION: proximal perigraft endoleak (PPE) and graft migration are associated with significant morbidity and mortality. Objective data establishing correlation between neck anatomy and these complications are lacking. The aim of this study was to analyse the anatomy of the neck in order to find which variables were significantly associated with PPE and graft migration. METHODS: one hundred and eighty-four patients underwent endovascular repair (EVR) of infrarenal AAA using an in-house custom-made stent graft (Gianturco stents plus Dacron). Thirty-one patients had PPE and fifteen had graft migration. Neck diameter was measured at the level of renal arteries and lower limit of the neck. Necks were classified according to shape. Neck angulation was measured from spiral computed tomography (CT) or magnetic resonance imaging (MRI) reconstructions, or angiograms. Thrombus or atheroma lining and presence of calcifications were recorded. RESULTS: neck angulation was significantly greater in patients who had PPE (50+/-16, p=0. 0005) or graft migration (54+/-20, p=0.003), compared to patients who had none of these two complications (37+/-18). Neck diameter was significantly greater in patients with PPE (p=0.05). Incidence of PPE or graft migration was not significantly higher in the presence of a conical shape, thrombus or atheroma lining and calcifications. CONCLUSION: neck angulation was the risk factor most significantly related to PPE and graft migration.

Anastomosis, Surgical↗

Feasibility of using dynamic contrast-enhanced magnetic resonance angiography as the sole imaging modality prior to endovascular repair of abdominal aortic aneurysms.

OBJECTIVES: to establish the feasibility of using magnetic resonance imaging (MRI) with dynamic contrast-enhanced (DCE) MRA as the sole imaging modality in the assessment of patients prior to endovascular repair of abdominal aortic aneurysms (AAAs). DESIGN: DCE MRA with MRI and helical computed tomography (CT) examinations were performed in patients being assessed for suitability for an endovascular approach to repair of their AAA. Management outcomes determined by the two techniques were compared. MATERIALS: sixteen patients with AAA. METHODS: all subjects underwent DCE MRA/MRI and helical CTA. Criteria for suitability for endovascular repair were established. The management outcomes determined by the MRI findings were compared with those obtained by CTA. RESULTS: high-quality MRA/MRI and CT images were obtained in 16 patients. Six patients were considered suitable for an endovascular approach, one was considered borderline and nine were judged unsuitable. In all cases, the overall management determined by the two methods concurred. CONCLUSIONS: comparison of the two imaging modalities resulted in agreement as to suitability for an endovascular approach. We therefore conclude that in our group the use of MRI and DCE-MRA proved effective as a sole imaging modality for the assessment of these patients.

Aged↗

Incidence and treatment of intraoperative technical problems during endovascular repair of complex abdominal aortic aneurysms.

PURPOSE: The purpose of this study was to assess the incidence and management of intraoperative technical problems during endovascular repair (EVR) of complex abdominal aortic aneurysms (AAA). METHODS: From February 1995 to March 1999, 204 EVRs of nonruptured AAA were performed at our institution. One hundred seventy-six patients had an in-house custom-made graft; 172 were aorto-uni-iliac grafts, and four were aortoaortic grafts. Twenty- eight patients had a bifurcated graft. One hundred fourteen patients (56%) were high risk for conventional open repair. One hundred nine patients (53%) were not suitable for most commercially available devices. RESULTS: Intraoperative technical problems occurred in 81 patients (40%). There were 37 endoleaks (27 proximal, 10 distal), 15 graft stenoses, one failure of graft deployment, two graft thromboses, three aortoiliac ruptures, five renal artery occlusions (one bilateral, four unilateral), and 18 internal iliac occlusions (five bilateral, 13 unilateral). Endovascular management of these problems was successful in 37 of the 81 patients (46%) and included 15 balloon dilatations, 21 additional stent placements, and one graft thrombectomy. Fifteen of the 81 patients (19%) had open procedures (four periaortic ligature placements, six open aneurysm repairs, three common iliac ligations, and two extra-anatomic bypass grafts). In the remaining 29 patients, the on-table problem was managed expectantly. During follow-up, two of 37 patients (5%) who were treated successfully with endovascular procedures experienced recurrence. There were five deaths (33%) among the 15 patients who underwent open procedures. CONCLUSION: Intraoperative problems occur frequently during the endovascular management of complex aneurysms. Many of these problems can be managed with additional endovascular techniques without an increased risk of recurrence or procedure-related complications. Open procedures in high-risk patients carry a high mortality rate. The team performing EVR of AAA should be skillful in advanced endovascular and open surgical procedures.

Aged↗

Sigmoid ischemia and the inflammatory response following endovascular abdominal aortic aneurysm repair.

PURPOSE: To assess the relationship between sigmoid colonic perfusion, endotoxemia, and cytokine generation in patients undergoing elective open repair (OR) or endovascular repair (EVR) of infrarenal abdominal aortic aneurysms (AAA). METHODS: Ten patients (9 males; average age 67.6 +/- 2.5 years, mean aneurysm diameter 6.9 +/- 0.6 cm) undergoing OR were compared to 10 patients (all males; average age 70.3 +/- 2.6 years, mean aneurysm diameter 6.5 +/- 0.5 cm) whose repair was performed using the EVR technique. The partial pressure of the carbon dioxide gap (PCO2gap = tissue PCO2 - arterial PCO2) of the sigmoid colonic mucosa was measured using a silicone tonometer to evaluate bowel perfusion. Blood samples were collected into pyrogen-free heparinized tubes for quantification of plasma concentrations of endotoxin, tumor necrosis factor alpha (TNF-alpha), and interleukin 6 (IL-6) before, during, and after aortic repair. RESULTS: Patients in the OR group had a significantly greater increase in PCO2gap, suggesting a greater degree of bowel ischemia compared to the EVR group. This was associated with significantly greater postoperative concentrations of endotoxin, TNF-alpha, and IL-6 in the OR group. A significant correlation was found between PCO2gap, IL-6, and postoperative core temperature. CONCLUSIONS: The results suggest that the degree of bowel ischemia, endotoxemia, and cytokine generation following elective infrarenal AAA reconstruction may be reduced if the endovascular technique is used instead of conventional surgery.

Aged↗

A study on the patency of the inferior mesenteric and lumbar arteries in the incidence of endoleak following endovascular repair of infra-renal aortic aneurysms.

OBJECTIVE: An endoleak is defined as the presence of contrast medium within the aneurysm sac on post-operative contrast-enhanced computed tomography scans (CT) in patients following endovascular repair (EVR) of abdominal aortic aneurysms (AAA). The aim of this study was to correlate the incidence of endoleaks with the presence of patent lumbar (LA) and inferior mesenteric arteries (IMA) as seen on pre-operative angiography. DESIGN, MATERIALS AND METHODS: Forty-seven patients were assessed pre-operatively by both CT and angiography by a blinded radiologist prior to EVR of AAA. The number and size of patent vessels was recorded and correlated with the incidence of LA or IMA endoleaks on follow-up CT. Patent lumbar vessels were scored: 1 = small, 2 = medium, 3 = large. RESULTS: Five patients were noted to have patent IMA on pre-operative angiography but none developed an endoleak. In this series, five patients had an endoleak due to a patent LA. The median score for patients with no endoleak was 1 (0-9) and for those with a lumbar endoleak 2 (0-5) (P = 0.26, Mann-Whitney U-test). The number of patent lumbar arteries was not predictive of a subsequent endoleak. Two out of nine (22 %) patients with large patent LA subsequently developed an endoleak. If a policy of pre-operative embolization on the basis of large patent LA had been adopted, seven patients would have had an unnecessary invasive procedure. CONCLUSION: Pre-operative angiography to look for patent LA and IMAs is not required in patients undergoing EVR or AAA.

Aortic Aneurysm, Abdominal↗

Blood product requirements in patients undergoing elective endovascular abdominal aortic aneurysm repair.

OBJECTIVE: Endovascular repair (EVR) of abdominal aortic aneurysm (AAA) has many potential advantages, one of which may be reduced blood product requirements. The aim of this study was to compare the current blood product usage in our unit for three types of elective operation: EVR of AAA, open AAA repair and femorofemoral crossover grafts. DESIGN: Prospective data analysis with historical controls. MATERIALS: One-hundred and thirty-two patients undergoing elective EVR of AAA, 35 patients undergoing elective open repair of AAA and 37 patients having femorofemoral crossover grafts. METHODS: Data was collected on the blood product requirements of patients having EVR of AAA, with open AAA repair and femorofemoral crossover graft providing historical controls. RESULTS: There was no difference in the haematological parameters preoperatively between the three groups but postoperatively patients having EVR had a slightly lower haemoglobin than the open group (10.6 g/dl vs. 10.85 g/dl, p = 0.015). The number of patients who received blood transfusion in the EVR group was 82/132 (62%) and the open group 27/35 (77%), p = 0.4. CONCLUSION: Patients undergoing EVR of AAA require blood transfusion in the same numbers when compared to those undergoing open repair.

Aortic Aneurysm, Abdominal↗