PubMed Health⌕ Search

Biomedical subjects

S Walkinshaw

Publications and source records attributed to S Walkinshaw.

16 recordsLinked to original sources

Outcome of congenital lung abnormalities detected antenatally.

To determine the outcome of congenital lung abnormalities, data were collected retrospectively between January 1991 and December 1996 on any foetus found to have a lung lesion on antenatal ultrasound. A total of 23 foetuses had lung lesions on antenatal ultrasound. In two foetuses the antenatal ultrasound showed bilateral enlarged "bright" echogenic lungs with evidence of hydrops. Both pregnancies were terminated and tracheal atresia was confirmed. In 15 foetuses the antenatal ultrasound appearance was of a unilateral "bright" echogenic lung. There was one case of bronchial atresia and two cases of congenital lobar emphysema, which all had surgery. In nine cases there was a reduction in the size of the lesion on serial antenatal ultrasounds and no lesion was detected after birth. In three cases a small lesion was present after birth on chest radiography. In six foetuses the antenatal ultrasound appearance was of unilateral cystic or mixed cystic and echogenic lung lesions. Two pregnancies were terminated; both had congenital cystic adenomatoid malformation. Four pregnancies were continued and three infants had surgery soon after birth and were confirmed to have had congenital cystic adenomatoid malformation. One infant has been managed conservatively. In conclusion, a definitive diagnosis cannot usually be made antenatally. A large lesion on initial scan does not necessarily predict a poor outcome. The natural history of small asymptomatic postnatal lesions is unknown and a long-term prospective study is needed to determine the outcome of these lesions.

Cystic Adenomatoid Malformation of Lung, Congenita↗

Pregnancy does not adversely affect renal transplant function.

Women with functioning transplanted kidneys often become fertile again. Indeed, renal function, endocrine status and libido rapidly improve after renal transplantation, and 1:50 women of childbearing age become pregnant. However, there is concern regarding the haemodynamic changes of pregnancy, which could lead to a decline in graft function (temporary or permanent). We examined obstetric data and renal parameters in 29 patients and 33 pregnancies. Mean serum creatinine and creatinine clearance remained stable throughout pregnancy and 1 year postpartum. However, there was a significant increase in proteinuria from a mean of 0.45 g/24 h around the time of conception to 1.11 g/24 h at delivery (p<0.05). The proteinuria resolved to baseline levels at 3 months postpartum. We highlight certain parameters to be considered before conception to allow a good obstetric outcome and prolong stable renal function: serum creatinine <150 micromol/l, proteinuria <1 g/day, absence of histological evidence of chronic allograft rejection, controlled blood pressure (140/90) and stability of maintenance immunosuppression.

Adult↗

Dysfunctional labour: a randomised trial.

Sixty-one women making slow progress in the active phase of spontaneous labour with intact membranes were randomised to oxytocin and amniotomy, amniotomy only or expectant management. The data show that oxytocin significantly increases the rate of cervical dilatation and shortens prolonged labour, when compared with amniotomy alone and expectant management (P = 0.0144 and 0.0006, respectively). The impact on the operative delivery rate and neonatal outcome is difficult to assess due to the small number of relevant adverse outcomes. Women reported higher satisfaction score in the two groups where intervention followed the diagnosis of dysfunctional labour.

Adult↗

Partogram action line study: a randomised trial.

OBJECTIVE: To assess the effect of three different partograms on caesarean section and maternal satisfaction. DESIGN: Prospective randomised clinical trial. SETTING: Regional teaching hospital in North West of England. PARTICIPANTS: Nine hundred and twenty-eight primigravid women with uncomplicated pregnancies who presented in spontaneous labour at term. INTERVENTIONS: The women were randomised to have their progress of labour recorded on a partogram with an action line 2, 3 or 4 hours to the right of the alert line. If the progress reached the action line, a diagnosis of prolonged labour was made. Prolonged labour was managed according to the standard ward protocol. MAIN OUTCOME MEASURES: Primary: Caesarean section rate and maternal satisfaction; secondary: need for augmentation, duration of labour, analgesia, cord blood gas analysis, postpartum haemorrhage, number of vaginal examinations, Apgar score and admission to special care baby unit. RESULTS: Caesarean section rate was lowest when labour was managed using a partogram with a 4-hour action line. The difference between the 3- and 4-hour partograms was statistically significant (OR 1 8, 95% CI 1.1-3.2), but the difference between 2 and 4 hours was not (OR 1.4, 95% CI 0.8-2.4). The women in the 2-hour arm were more satisfied with their labour when compared to the women in the 3-hour (P < 00001) and 4-hour (P <00001) arm. CONCLUSION: Our data suggest that women prefer active management of labour. It is possible that partograms which favour earlier intervention are associated with higher caesarean section rate. As the evidence on which to base the choice of partograms remains inconclusive further research is required.

Cesarean Section↗

Second trimester serum free beta human chorionic gonadotrophin levels as a predictor of pre-eclampsia.

BACKGROUND: To prospectively assess maternal serum free beta human chorionic gonadotrophin (beta hCG) estimation between 15 and 18 weeks gestation, as a screening test for pre-eclampsia in primigravid women. METHODS: A prospective longitudinal study in a University Teaching Hospital. The study population was 430 primigravid women, who had maternal serum free beta hCG levels measured as part of antenatal serum screening for Down's Syndrome in the second trimester, who booked consecutively within the unit and went on to deliver on the unit's labor ward. These women were followed during their subsequent pregnancy and categorized into those who remained normotensive and those who developed pre-eclampsia on both clinical and biochemical grounds. The beta hCG levels were used to construct a receiver operator characteristics curve (ROC) to assess the screening potential for pre-eclampsia. RESULTS: Nineteen (4.4%) women in the study group developed pre-eclampsia. The median second trimester free beta hCG multiples of the median (MOM) was significantly elevated compared to that of the control group (1.52 vs 1.10, p=0.03). The ROC curve shows that for a sensitivity of 79%, the specificity was only 54%. CONCLUSIONS: Maternal serum free beta hCG alone measured in the second trimester is not clinically useful as a screening test for pre-eclampsia in primigravid women. It has, however, some predictive value.

Adolescent↗

Outcomes of pregnancy in insulin dependent diabetic women: results of a five year population cohort study.

OBJECTIVE: To monitor pregnancies in women with pre-existent insulin dependent diabetes for pregnancy loss, congenital malformations, and fetal growth in a geographically defined area of north west England. DESIGN: Population cohort study. SETTING: 10 maternity units in Cheshire, Lancashire, and Merseyside which had no regional guidelines for the management of pregnancy in diabetic women. SUBJECTS: 462 pregnancies in 355 women with insulin dependent diabetes from the 10 centres over five years (1990-4 inclusive). MAIN OUTCOME MEASURES: Numbers and rates of miscarriages, stillbirths, and neonatal and postneonatal deaths; prevalence of congenital malformations; birth weight in relation to gestational age. RESULTS: Among 462 pregnancies, 351 (76%) resulted in a liveborn infant, 78 (17%) aborted spontaneously, nine (2%) resulted in stillbirth, and 24 (5%) were terminated. Of the terminations, nine were for congenital malformation. The stillbirth rate was 25.0/1000 total births (95% confidence interval 8.9 to 41.1) compared with a population rate of 5.0/1000, and infant mortality was 19.9/1000 live births (5.3 to 34.6) compared with 6.8/1000. The prevalence of congenital malformations was 94.0/1000 live births (63.5 to 124.5) compared with 9.7/1000 in the general population. When corrected for gestational age, mean birth weight in the sample was 1.3 standard deviations greater than that of infants of non-diabetic mothers. Infants with congenital malformations weighed less than those without. CONCLUSION: In an unselected population the infants of women with pre-existent insulin dependent diabetes mellitus have a 10-fold greater risk of a congenital malformation and a fivefold greater risk of being stillborn than infants in the general population. Further improvements in the management of pregnancy in diabetic women are needed if target of the St Vincent declaration of 1989 is to be met.

Abortion, Spontaneous↗

Antenatal and neonatal renal vein thrombosis: new ultrasonic features with high frequency transducers.

The ultrasonic appearances of two infants with renal vein thrombosis (RVT) are described. One infant presented in the neonatal period and one antenatally. Consistent with previous reports, one or both kidneys were enlarged, with a generalised increase in echogenicity and vascular or perivascular streaking compatible with interlobular and arcuate vessel occlusion. Using high frequency transducers (7. 0-10 MHz), we identified new features during the course of the disease. The apex of the renal papilla became hypo-echoic and there was a ring of reduced echogenicity around the affected pyramids 1-2 weeks after the acute phase. These features correlate with the known pathophysiological course of RVT, but have not been previously described using ultrasound. The features are illustrated and the mechanism is discussed.

Adult↗

The presence of fetal fibronectin in the cervicovaginal secretions of women at term--its role in the assessment of women before labor induction and in the investigation of the physiologic mechanisms of labor.

OBJECTIVE: Our purpose was to determine whether the presence of fetal fibronectin in cervicovaginal secretions of patients undergoing induction of labor reflected the cervical state and ultimately the ease of induction of labor. STUDY DESIGN: A prospective observational study of 103 patients undergoing induction of labor at term was conducted at Liverpool Maternity Hospital, a large university teaching hospital. We studied the women after 37 completed weeks of pregnancy. A Dacron (Adeza Biomedical, Sunnyvale, Calif.) polyester swab specimen was first taken from the endocervix for assessment of the presence of the fetal fibronectin. The cervix was then assessed by digital vaginal examination and scored with a modified Bishop's score. The fetal fibronectin swab was processed at the bedside with a membrane immunoassay kit specific for fetal fibronectin. A score was ascribed depending on the strength of the fibronectin reaction determined by the intensity of the color change on the plate, the presence of fetal fibronectin resulting in a score of 1 to 4. The patient was subsequently managed according to the standard induction protocol of the unit. The clinicians involved in the patient's care were blind to the result of the fetal fibronectin swab. RESULTS: There was a good correlation between the modified Bishop's score and the fetal fibronectin score (r = 0.58, p < 0.001). To predict a latent phase of < 8 hours, a fetal fibronectin score of 3 or 4 has a sensitivity of 73% with a specificity of 83% and a modified Bishop score of > or = 4 has a sensitivity of 75% and a specificity of 73%. For delivery within 12 hours of induction of labor a fetal fibronectin score of > or = 3 has a sensitivity of 61% and specificity of 83% compared with the modified Bishop score of > or = 4, which has a sensitivity of 76% and a specificity of 72.5%. CONCLUSIONS: The fetal fibronectin score is as good as the modified Bishop score as an index of the ease with which induction of labor may be performed. This would imply that it also reflects the proximity of the onset of labor. The presence of fetal fibronectin cervicovaginal secretions is therefore a marker of the changes in the cervix and membranes that precede labor regardless of the gestational age.

Adolescent↗

Fetal echogenic lung lesions: prenatal ultrasound diagnosis and outcome.

The differential diagnosis of echogenic areas in the fetal chest include congenital diaphragmatic hernia (CDH), cystic adenomatoid malformation (CAM), sequestrated lung and tracheal or bronchial atresia. The purpose of this study was to evaluate the accuracy of prenatal diagnosis and document outcome in fetuses with echogenic chest lesions. Seventeen fetuses with echogenic chest masses were seen in our unit between 17 and 36 weeks' gestation over a 5-year period. We reviewed these cases retrospectively for prenatal diagnosis, postnatal diagnosis and outcome. Prenatal diagnosis was correct in 13 fetuses, with CDH in 8, sequestrated lung in 4 and tracheal atresia in 1. Four fetuses had incorrect or uncertain prenatal diagnoses. In three fetuses CDH and CAM could not be differentiated. After delivery two of these had CDH and one had sequestrated lung. One fetus with bilateral lesions had prenatal diagnosis of bilateral CAM. Post-mortem examination revealed tracheal atresia as part of Fraser syndrome. All five babies with sequestrated lung are well and none required surgery. Ten fetuses had CDH, two pregnancies were terminated, one died in utero, five died as neonates and two babies survived following surgery. The study reveals that in a minority of fetuses CDH and CAM could not be differentiated prenatally. We agree with recent reports of fetal sequestrated lung describing sonographic improvement in utero. A large lesion on initial scan does not necessarily predict a poor neonatal outcome in this condition. This, together with the poor outcome in fetuses with echogenic CDH and tracheal atresia, has important implications for prenatal counselling.

Bronchopulmonary Sequestration↗

Isolated choroid plexus cysts--the need for routine offer of karyotyping.

The management of isolated fetal choroid plexus cysts remains controversial. We have prospectively studied 15,565 pregnancies at two large obstetric units for the presence of choroid plexus cysts. In all cases where cysts were present at 19 weeks' gestation or greater, and were multiple, bilateral or solitary and greater than 5 mm maximum diameter, women were offered amniocentesis or placental biopsy, irrespective of the presence or absence of other abnormalities. Choroid plexus cysts were present in 152 (0.98 per cent) of cases. Four cases (2.6 per cent) of autosomal trisomy (three of trisomy 18, one of trisomy 21) were detected on prenatal karyotyping. In all cases, choroid plexus cysts were the only detectable prenatal anomaly. This study and a review of other large studies do not support the view that isolated choroid plexus cysts are a benign variant, the risk of trisomy being 1 in 82. Until further evidence is available, we recommend that cases of isolated fetal choroid plexus cysts at 19 weeks' gestation or greater should be offered prenatal karyotyping.

Amniocentesis↗

Steroids for babies.

Explore the source record for details and available documents.

Adrenal Cortex Hormones↗

Phenytoin prophylaxis in severe pre-eclampsia and eclampsia.

OBJECTIVE: To determine plasma phenytoin levels and seizure outcome in women given phenytoin for seizure prophylaxis in severe pre-eclampsia and eclampsia. DESIGN: Prospective observational study comparing two phenytoin loading regimens. SETTING: Two UK teaching hospitals. SUBJECTS: Sixty-seven consecutive women with severe pre-eclampsia and five with eclampsia. INTERVENTIONS: The first 29 women were given a 15 mg/kg intravenous loading dose of phenytoin. The next 43 received 17.5 mg/kg. All were given 500 mg phenytoin 12 h after completion of the loading dose and then 250 mg every 12 h for four doses. MAIN OUTCOME MEASURES: Total plasma phenytoin levels at 30 min, 6 h and 12 h after loading dose, 6 h after first maintenance dose and on days 2 and 3 of maintenance therapy; eclamptic seizures after starting phenytoin. RESULTS: Mean plasma phenytoin levels were higher at 30 min and 6 h after the 17.5 mg/kg loading dose. Nine of 29 (31%) phenytoin levels 30 min after the loading dose were above the therapeutic range in the 15 mg/kg group compared with 26/38 (68%) in the 17.5 mg/kg group (P < 0.01). Six of 27 (22%) phenytoin levels 12 h after the loading dose were subtherapeutic in the 15 mg/kg group compared with 2/38 (5%) in the 17.5 mg/kg group (P < 0.05). Three women, two in the 17.5 mg/kg group, developed seizures after starting phenytoin. All three had plasma levels within the therapeutic range. CONCLUSIONS: Compared with a loading dose of 17.5 mg/kg, loading with 15 mg/kg phenytoin was associated with a lower incidence of high plasma levels at 30 min but a higher incidence of subtherapeutic levels at 12 h. Seizures occur in 2 to 3% of pre-eclamptics despite apparently therapeutic phenytoin levels.

Adult↗

Undiagnosed breech.

OBJECTIVES: To assess the proportion of breech presentations diagnosed in labour and to compare their outcomes with those diagnosed prior to the onset of labour. DESIGN: Retrospective casenote review. SETTING: Mill Road Maternity Hospital, a teaching hospital in central Liverpool. SUBJECTS: Three hundred and five singleton breech presentations delivered in the hospital between January 1988 and July 1991; 226 cases prior to the onset of labour and 79 cases diagnosed for the first time in labour. MAIN OUTCOME MEASURES: Rates of vaginal delivery and caesarean section, birthweight, short term morbidity as assessed by trauma, signs of cerebral irritation and admission to the newborn intensive care unit (NBICU), and Apgar scores. RESULTS: Breech presentations diagnosed for the first time in labour were more likely to deliver vaginally than those assessed and allowed to go into labour (odds ratio 1:68 95% CI 1.0-3.0). This difference was not due to demographic variables or differences in birthweight. There was no short term morbidity attributable to vaginal breech delivery. CONCLUSION: A significant number of breech presentations are not detected until labour despite rigorous antenatal surveillance. Our results show that undiagnosed breeches may not be important as they are more likely to deliver vaginally, with no excess morbidity or mortality, compared to diagnosed breeches in labour, carefully assessed for vaginal delivery. There are, therefore, no grounds for delivering all undiagnosed breeches by caesarean section.

Adolescent↗

The prediction of fetal compromise and acidosis by biophysical profile scoring in the small for gestational age fetus.

In a prospective blind study, 133 fetuses suspected of being small for gestational age (SGA), defined as an estimated fetal weight less than the 10th centile for gestation, were monitored by weekly biophysical profile assessment. Perinatal outcome was assessed by umbilical venous blood pH estimation and compared with the profile score determined within seven days of delivery. The positive and negative predictive values of the full biophysical profile score were not significantly better than combinations of two or three of the individual components in this group of fetuses. The use of amniotic fluid volume, non-stress testing and either fetal movement or breathing offers an acceptable alternative to full biophysical profile assessment in the fetus suspected of being small for gestation.

Acidosis↗