Multifocal cardiac leiomyosarcoma. Diagnosis and surveillance by transoesophageal echocardiography and contrast enhanced cardiovascular magnetic resonance.

Primary cardiac sarcomas are rare and typically undergo aggressive local spread. There is no reliable definitive treatment, although radical surgical resection can provide palliation in the medium term. A case of a pleomorphic leiomyosarcoma with dramatic images is presented. The relative usefulness of transoesophageal echocardiography and cardiovascular magnetic resonance imaging to define the extent of tumour involvement, allowing planning of treatment, is demonstrated.

Echocardiography, Transesophageal↗

Infant partial left ventriculectomy for failure to wean from cardiopulmonary bypass.

Following aortic reimplantation of anomalous left coronary artery from the pulmonary artery in a 6-month-old infant, the heart failed to wean after prolonged supportive cardiopulmonary bypass and maximal inotropic support. We performed partial left ventriculectomy (Batista procedure) that halved left atrial pressure and enabled discontinuation of bypass. Postoperative recovery was then uneventful.

Cardiopulmonary Bypass↗

Is there a relationship between cognitive dysfunction and systemic inflammatory response after cardiopulmonary bypass?

BACKGROUND: The systemic inflammatory reaction (SIR) is assumed to be one of the factors that causes cerebral dysfunction after cardiopulmonary bypass (CPB). The aim of the present study was to evaluate the relationship between the SIR and postoperative cognitive performance at 5 days and 3 months. METHODS: One hundred patients undergoing coronary artery bypass grafting were studied. Inflammatory markers and markers of coagulation and fibrinolysis were determined at several time points during and after the operation. Correlation analysis between maximum levels of the different markers and early and late performance was performed. RESULTS: No overall association was found between the maximum levels of the inflammatory markers and early and late function. CONCLUSIONS: Notwithstanding limitations of statistical power established markers of systemic inflammatory reaction showed no relationship with outcome at 5-day or 3-month follow-up in this subset of patients.

Aged↗

Dental bar tracheopexy in a neonate.

Double aortic arch often presents with tracheoesophageal compression. Management requires division of the vascular ring and, if tracheomalacia is present, some form of tracheopexy. We report here the use of a dental bar as an external splint for tracheopexy in a neonate. Follow-up to 18 months shows good tracheal growth and no erosion.

Aorta↗

S100B as a predictor of size and outcome of stroke after cardiac surgery.

BACKGROUND: Stroke after cardiac surgery is a clinical problem with often fatal or disabling outcome. To assess severity and probable outcome in affected patients only from clinical and radiological examinations is difficult. The glial-derived protein S100B has been suggested to be a marker of cerebral ischemia, and increased blood concentrations of S100B have been shown to correlate with size of lesion and prognosis after stroke. We studied the validity of S100B as a predictor of size of brain lesion and median term outcome in a consecutive group of patients suffering from stroke after cardiac surgery. METHODS: During a period of 17 months, 20 patients with clinical signs of postoperative stroke were investigated with S100B measurement, sampled at 5, 15 and 48 hours after surgery. All patients were examined with computed tomography or magnetic resonance imaging to confirm the diagnosis, and the size of cerebral infarction was estimated from the radiological examinations. The patients were followed up for survival 24 to 39 months after surgery. RESULTS: S100B concentration in blood 48 hours after surgery correlated with the size of infarcted brain tissue (r = 0.68, p < 0.001). Nine patients had S100B levels exceeding 0.5 microg/L and a 2-year mortality of 78%, whereas the 11 patients with S100B below 0.5 microg/L had a mortality of 18%. CONCLUSIONS: Increased S100B in patients with a stroke following cardiac surgery correlate with the size of infarcted brain tissue. High S100B levels 48 hours after surgery have a negative predictive value for median term survival.

Aged↗

Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart.

Advances in technology and increased clinical need have led to the development of a new type of blood pump. The Jarvik 2000 Heart is an electrically powered, axial-flow left ventricular assist device that has been developed during the past 13 years. Unlike first-generation left ventricular assist devices, which were developed in the 1970s and were designed to totally capture the cardiac output, the Jarvik 2000 is designed to normalize the cardiac output by augmenting the function of the chronically failed heart for extended periods. Design iterations have been tested in 67 animals, and clinical trials have recently begun. Three patients have received the Jarvik 2000 as a bridge to transplantation, and 1 patient is being supported permanently outside the hospital. All 4 patients have improved from New York Heart Association functional class IV to class I, and 2 of them have been discharged from the hospital after heart transplantation. The experimental and clinical results indicate that the Jarvik 2000 can provide physiologic support with minimal complications and is reliable, biocompatible, and easy to implant.

Animals↗

Clinical results with the AB-180 left ventricular assist device.

BACKGROUND: This report reviews the initial clinical experience with the AB-180 ventricular assist device. METHODS: Between Dec 1997 and July 2000, the AB-180 was implanted in 17 patients at five institutions. The mean age was 52 years (range 21 to 68 years) and 14 of 17 were male. The indications for implantation were postcardiotomy shock (12 of 17, 70%), decompensated cardiomyopathy (2 of 17, 12%), viral myocarditis (2 of 17, 12%), and acute myocardial infarction (1 of 17, 6%). RESULTS: The mean duration of support was 8.5 days (range 1 to 28 days). In the group of 17 patients, 8 were weaned from the device and 2 underwent transplantation. Four of the weaned patients (4 of 8, 50%) and 1 of the transplant patients (1 of 2, 50%) survived. The overall weaning and survival rates were 58% (10 of 17) and 29% (5 of 17). There were no major device-related complications and no major device malfunctions. CONCLUSIONS: The AB-180 provides reliable circulatory support for reversible forms of heart failure.

Adult↗

Pericardial and porcine stentless aortic valves: are they hemodynamically different?

BACKGROUND: We sought to compare the early hemodynamic performance of pericardial stentless aortic valves with that of well-established porcine stentless aortic prostheses. METHODS: A total of 169 patients (97 men and 72 women, aged 73+/-6 years) undergoing aortic valve replacement received either a pericardial (Pericarbon, Sorin Biomedica, Saluggia, Italy; n = 89) or a porcine (Freestyle, Medtronic, n = 80) stentless aortic valve. Aortic valve hemodynamics and root dynamism were assessed by Doppler echocardiography at discharge and 12 months after implantation. RESULTS: Clinical demographic data, valve size (24.0+/-1.9 vs 24.6+/-2.3 mm), and body surface area (1.85+/-0.19 vs 1.80+/-0.19 m2) did not differ between porcine and pericardial valves (both p > 0.05). The 1-year postoperative mean valve pressure gradient (4.2+/-2.6 vs 3.7+/-2.6 mm Hg), effective orifice area (2.2+/-0.8 vs 2.2+/-0.8 cm2), and left ventricular ejection fraction (62+/-13 vs 63+/-13, %) also did not differ (all p > 0.05). However, at discharge, systolic increase in aortic sinus diameter was significantly greater in pericardial valves than in porcine ones (7.7+/-5.7 vs 4.9%+/-4.2%, p < 0.01). Furthermore, pericardial valves had a greater slope of effective orifice area-systolic aortic flow relationship (0.89+/-0.07 vs 0.70+/-0.06, cm2/100 mL/s, p < 0.01). CONCLUSIONS: Nonprosthetic thin-walled pericardial valves appear to offer better aortic root dynamism and more efficient hemodynamics than those of porcine valves immediately after implant. At 1-year follow-up, however, both types of stentless valves provide equally excellent hemodynamics. The clinical choice between the two will depend on their long-term durability.

Aged↗

Reliable long-term non-pulsatile circulatory support without anticoagulation.

OBJECTIVE: The Terumo implantable left ventricular assist system (T-ILVAS) consists of a titanium centrifugal pump with a unique magnetically suspended impeller producing continuous (non-pulsatile) flow up to 10 l/min. The interior surface is heparin-coated and there is no purge system. We implanted the device into six sheep to ascertain in-vivo haemodynamic function, mechanical reliability and biocompatibility. METHODS: The T-ILVAS was implanted via left thoracotomy without cardiopulmonary bypass. The inflow cannula was placed in the left ventricular apex and a Dacron outflow graft anastomosed to the descending aorta. All animals recovered well. No anticoagulation (heparin or warfarin) was given after the surgery. Suspension position, motor current, impeller speed and pump flow were continuously monitored and stored by on-line computer. Serial blood samples were collected to determine haematological and biochemical indices of renal function, liver function and haemolysis. All animals were electively euthanized between 3 and 7 months postoperatively. The explanted pumps were examined for mechanical reliability and thrombus formation. Major organs were examined macroscopically and histologically for thromboembolism. RESULTS: All animals appeared completely normal for up to 210 days. At speeds between 1500 and 2000 rev./min the device pumped up to 8 l/min capturing all mitral flow. There were no major complications (pump failure, thromboembolism, haemorrhage, or driveline infection). Indices of haemolysis, liver and renal function remained within normal limits. All pumps were mechanically sound and free from thrombus. One embolus was found in a sectioned kidney. CONCLUSION: The T-ILVAS successfully supported the systemic circulation without anticoagulation for up to 210 days. Mechanical reliability and biocompatibility were demonstrated. Organ function remained within normal limits during continuous non-pulsatile flow.

Animals↗

Development status of Terumo implantable left ventricular assist system.

We have been developing an implantable left ventricular assist system (T-ILVAS) featuring a magnetically suspended centrifugal pump (MSCP) since 1995. In vitro and in vivo studies using a prototype MSCP composed of a polycarbonate housing and impeller (196 ml) have demonstrated long-term durability and excellent blood compatibility for up to 864 days, and excellent stability of the magnetic bearing of the MSCP. These preliminary results strongly suggested that the magnetic bearing of the MSCP is reliable and is a most feasible mechanism for a long-term circulatory assist device. We have recently devised a clinical version pump made of titanium (180 ml) with a new position sensor mechanism and a wearable controller with batteries. Cadaver fit study confirmed that the Type IV pump could be implanted in a small patient with a body surface area as small as 1.3. The in vitro performance tests of the Type IV pump demonstrated excellent hydrodynamic performances with an acceptable hemolysis rate. New position sensors for the titanium housing showed more uniform sensor outputs of a magnetic bearing than in the prototype polycarbonate pump. The Type IV pump then was evaluated in vivo in 6 sheep at the Oxford Heart Centre. Four sheep were electively sacrificed at 3 months and were allowed to survive for more than 6 months for long-term evaluation. In this particular series of experiments, no anticoagulant/antiplatelet regimen was utilized except for a bolus dose of heparin during surgery. There was a left ventricular mural thrombi around the inflow cannula in 1 sheep. Otherwise, there was no mechanical failure nor sign of thromboembolism throughout the study.

Animals↗

Stentless bioprostheses in aortic root disease.

INTRODUCTION: The availability of aortic homografts is steadily decreasing. In the meantime, stentless xenografts convey similar flow characteristics, and tissue preservation methods are improving durability. Initially, these valves were contraindicated in aortic roots with discrepancy between annulus and sinotubular junction or with extensive calcification or sepsis. With increasing experience stentless xenografts are now applied in a wide spectrum of aortic root disease. METHODS: I reviewed our own experience with stentless aortic bioprosthesis for aortic valve replacement (AVR) and more taxing root problems. I used these valves in aortic aneurysm repair, acute Type A dissection, and for endocarditis with abcess formation. I studied valve hemodynamics, regression of left ventricular hypertrophy, and comparative survival with stented bioprostheses. RESULTS: Stentless bioprostheses convey hemodynamic and possibly survival benefit through a low incidence of valve-related complications. They provide a useful alternative to aortic homografts in endocarditis, Type A dissection, and aortic aneurysm surgery. CONCLUSIONS: Stentless bioprostheses are no longer confined to AVR alone. Experience supports the use of stentless bioprostheses where aortic homografts were previously applied. With availability in a wide range of sizes.

Animals↗

Neurological and cognitive disorders after coronary artery bypass grafting.

Cerebral injury is a major cause of mortality and morbidity of coronary artery bypass grafting. Stroke occurs in 3% of patients and is largely caused by embolization of atheromatous debris during manipulation of the diseased aorta. Cognitive impairment, which is predominantly caused by microembolization of gaseous and particulate matter, mainly generated by cardiotomy suction, is more common. Demonstration of similar cognitive impairment in patients operated on without cardiopulmonary bypass indicates that other pathophysiological mechanisms, such as anaesthesia and hypoperfusion, are also involved. Advances in medical, anesthetic, and surgical management have resulted in a reduction in the incidence of neurological injury in CABG patients over the past decade. On the other hand, an increasingly elderly population with more severe comorbidity, who are more prone to cerebral injury, are increasingly being referred for CABG. Possible mechanisms to reduce overt and subtle cerebral injury are discussed. The use of composite arterial grafts performed on the beating heart may be the most effective way of minimizing the risk of cerebral injury associated with CABG.

Biomarkers↗

Pericardial stentless aortic valves: effects of sizing on hemodynamics and root geometry.

The objective of this study was to determine the effects of sizing policy for pericardial stentless valves on hemodynamic performance and aortic root geometry. Discharge echocardiography was performed on 103 patients out of 110 consecutive implants (54 men and 49 women, mean age 75 +/- 9 years, and 36% with Co-CABG). Valve prosthesis size was based on largest annulus size plus 1 to 2 mm in the first 50 implants (group A, n = 48). Following continuous echo assessment, sizing policy was changed to annulus size plus 3 to 4 mm in the next 60 implants (group B, n = 55). Sinotubular (ST) junction was kept within 115% of the annulus size by surgical remodeling of aortic root. In comparison with group A, group B had a 7% larger valve size (25.2 +/- 2.1 mm v 23.6 +/- 2.3, mm, P <.01) implanted for patients of same body surface area and left ventricular cavity size. However, group B has a 38% lower mean pressure gradient (4.0 +/- 2.7 v 6.5 +/- 3.2, mm Hg, P <.01), a 32% greater effective orifice area (2.3 +/- 0.9 cm(2) v 1.7 +/- 0.7 cm(2), P <.01), better root distensibility (9.3% +/- 6.0% v 6.8% +/- 4.1%, P =.026), and a lower ratio of ST junction to valve size (0.92 +/- 0.13 v 0.99 +/- 0.14, P =.009). Group B also had lower grade of prosthesis regurgitation (0.35 +/- 0.62 v 0.89 +/- 1.1, P =.002). Sizing of pericardial stentless aortic valves by annulus diameter plus 3 to 4 mm provides better valve competence and hemodynamic efficiency by improving aortic root geometry and distensibility. Pericardial stentless valves may be of advantage in elderly patients with significant geometric root mismatch.

Aged↗

In vivo hemodynamic characteristics of porcine stentless aortic valves.

The objective of this study was to elucidate the relationship of aortic pressure gradient (mPG) and effective orifice area (EOA) with mean systolic flow rate of left ventricle in patients who received a stentless aortic valve. Two hundred thirteen patients (age: 73 +/- 6 years, 123 men and 90 women) who received a Freestyle stentless valve in subcoronary position for aortic valve diseases were studied. EOA, mPG, and systolic aortic flow rate were determined by Doppler echocardiography at 1 and 20 months after implant. With follow-up, there was a 13% increase in EOA and a 30% decrease in mPG, both P <.01. Although systolic aortic flow did not change, the intercept of EOA-flow relationship increased significantly at late follow-up (0.56 +/- 0.13 v 0.11 +/- 0.13, P <.01). Multiple regression analysis showed that systolic aortic flow accounted for 54%, and mPG for only 27%, variation of EOA. Linear relationship between EOA and systolic aortic flow provides a comprehensive approach to describe stentless valve performance, when mean valve pressure gradient appears to be flow independent. These hemodynamic features distinguish stentless valves from stented or mechanical prosthesis. Ultimately, the variations in aortic root anatomy, surgical experience and their interactions are likely to become major determinants of in vivo performance of stentless aortic valves.

Aged↗

Does the use of a stentless bioprosthesis increase surgical risk?

Stentless aortic bioprostheses (SBPs) convey hemodynamic and perhaps survival benefit over stented counterparts. The aim of this study was to determine whether the more taxing operation increases surgical risk. We studied contemporary multicenter (USA) data submitted to the Food and Drug Administration (FDA) for Freestyle stentless (group I, n = 583) and Mosaic stented xenograft approval (group II, n = 1260). The study compared 30-day mortality for the two groups overall, then for isolated aortic valve replacement (AVR) and for AVR and coronary bypass (CABG). Because the USA Freestyle valves were used in selected patients (pts) we included SBP data (group III) from Oxford, where Freestyle valves were used consecutively within the same time frame. We also reviewed hospital mortality in the stentless bioprosthesis literature and compared this with the Society of Thoracic Surgery Database. There were no differences in age, NYHA, or incidence of CABG between the groups. There was no significant difference in operative mortality between stented (group II) and exclusive (group III) SBP patient groups (P =.233 for AVR and P =.478 for AVR + CABG), or between selective (group I) and exclusive (P =.929 for AVR and P =.390 for AVR + CABG) groups, after adjustment for risk factors. However, there was a significantly higher mortality both for isolated AVR (P =.026) and AVR + CABG (P =.001) in the selected stentless group compared with stented. This was partly attributed to greater mortality when the Freestyle was used in elderly patients by the full root replacement method, and to the higher proportion of females, and subjects with intra-aortic balloon pump insertion in this group. A meta-analysis of published stentless valve series, showed mortality rates to be lower than those of the STS National Database average. During the learning curve selective use of SBPs increased hospital mortality for AVR +/- CABG. Consecutive use dispelled the difference and the literature now suggests that SBPs may reduce hospital mortality for high-risk patients.

Aged↗