PubMed Health⌕ Search

Biomedical subjects

S Wirth

Publications and source records attributed to S Wirth.

At least 19 recordsLinked to original sources

[Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

BACKGROUND: The purpose of this study was to evaluate the value of C-arm CT imaging of the distal radius with standard patient positioning in intraoperative assessment of plate osteosynthesis. MATERIALS AND METHODS: Four complete distal radius specimens from human cadavers were fractured (type C), and internal fixation with palmar plates (stainless steel) was then carried out in each. On the basis of C-arm fluoroscopy, radiography and C-arm CT (Siremobil Iso-C3D, scans with forearm bones positioned parallel to the z-axis), 19 observers subsequently evaluated the positions of screws near the joint and any steps within the joint, after which the bones were surgically exposed and the imaging results checked against direct visual observations. RESULTS: No statistically significant differences were detected either between the modalities or between the evaluator groups. CONCLUSION: With standard patient positioning, the performance of C-arm CT was equivalent to and not better than that of current standard procedures, i.e. intraoperative fluoroscopy and postoperative radiography. Further studies should examine whether this holds true in clinical practice with representative patient collectives when titanium implants are used and/or optimized patient positioning is practised.

Cadaver↗

[The undetected brain lesion in sports. Minor traumatic brain injury and its sequelae].

The minor traumatic brain injury (mTBI) in sports is often looked at as a bagatelle. The treating physician underestimates the severity of the injury suspecting that a mTBI is a nonstructural lesion with an overall excellent prognosis in the majority of the cases. This paper shows that the minor traumatic brain injury may be a structural brain lesion with potentially life-threatening dangers. The therapy should follow exactly defined guidelines, e.g., stepwise protocol of the Concussion in Sports (CIS-) Group. Return to sports activities should happen only when all physical but also cognitive symptoms have subsided. All mTBIs that have been sustained prior to the actual injury have to be recorded properly because repeated mTBIs may cause chronic degenerative brain damage. Neuropsychological testing will aid in the correct diagnosis of a mTBI and is a useful parameter in the course of the injury. In the future biochemical markers may serve as indicators of the severity of the brain injury and may also aid in predicting the outcome after TBI. Today biochemical markers do not serve as a substitute for neuroimaging.

Adolescent↗

[Soft tissue manifestations of early rheumatic disease: imaging with MRI].

PURPOSE: The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. MATERIAL AND METHODS: A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. RESULTS: The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a particular rheumatic disease (PsA; r=0.934; sensitivity 84.9%, specificity 82.4%). CONCLUSION: Inflammatory conditions of the hand can be reliably detected with MRI. In many cases the definite diagnosis can only be made when taking clinical, serological, and radiographic results into account (+13.7% increase of significance).

Adult↗

Influence of HMG-CoA-reductase inhibitors on the body fat status.

BACKGROUND: While the literature has conclusively shown a significant decrease of plasma lipids after intake of HMG-CoA reductase inhibitors, there is no detailed information provided about their effects on the body fat status. PATIENTS AND METHODS: We performed a retrospective analysis of a prospective randomized controlled trial including consecutive patients with suspected arterial occlusive disease. Normolipidemic patients served as the control group and hyperlipidemic patients were randomized to either 20 mg atorvastatin or to 40 mg simvastatin. At baseline, after 6 weeks and after 6 months we assessed the relative body fat, the waist circumference and the body mass index (BMI) as well as plasma total cholesterol (chol), low-densitiy lipoprotein cholesterol (LDL) and triglycerides (TG). RESULTS: In total we included 129 patients in our analysis. The body fat status remained unchanged in the control group as well as in the atorvastatin group (all p > 0.05) for the whole study period, while simvastatin treatment led to a slight, but significant increase of the relative body fat (+ 4.2%) between the 6 weeks and 6 months assessment (p = 0.013). CONCLUSIONS: Long-term intake of statins seems to have no positive influence on parameters of the body fat status and therefore misses one important goal in the cardiovascular risk prevention.

Adipose Tissue↗

Skin cholesterol: test performance, evaluation of potential determinants and correlation analysis with cardiovascular risk factors and circulating markers of inflammation.

BACKGROUND: Skin cholesterol (SkC) has been suggested to be an additional risk predictor, so we evaluated the test performance, potential determinants of this marker as well as a potential correlation of SkC with markers of inflammation and the history of cardiovascular events. PATIENTS AND METHODS: SkC, determined by the non-invasive PREVU POC Skin Sterol test, as well as serum lipids, the body fat status, high-sensitive CRP (hs-CRP) and serum amyloid A (SAA) were evaluated in consecutive patients with and without documented atherosclerotic disease. RESULTS: SkC was assessed in 201 patients. The within-day precision (CV) was 3.8%, the day-to-day CV of the right hand was 8.6% and 4.3% for the left hand, respectively. Neither univariate analysis nor multiple regressions identified a significant influence of age, sex, serum lipids, body fat status, smoking or diabetes mellitus on SkC, corresponding results were observed in a further analysis including 174 of these patients concerning hs-CRP and SAA (all p > 0.05). T-test analyses detected no significant differences between patients with and without a history of coronary, peripheral vascular and cerebrovascular events (all p > 0.05). CONCLUSIONS: The PREVU POC Skin Sterol test for the assessment of SkC proved an acceptable test performance. SkC is independent from serum lipids, traditional cardiovascular risk factors, two sensitive markers of systemic inflammation as well as the history of cardiovascular events indicating that the perception of this parameter as an established marker of vascular disease is premature.

Aged↗

[Comparison of different review displays with respect to the detection of low-contrast details in digital radiographs].

PURPOSE: Assessment of low-contrast details in digital radiographs on different review displays (RD). MATERIALS AND METHODS: 20" flat screen panels (RD1: standard color LCD-TFT, RD2: monochrome LCD-TFT for radiological reading, RD1*: RD1 with optional image inversion; 205 cd/m (2) luminance, respectively) were evaluated. At 30 lx ambient lighting, 10 radiologists gradually increased the contrast (constant steps) for both a homogeneous picture and a cutout of a thorax radiography of n = 480 simulated nodules until they became recognizable. RESULTS: In the case of bright nodules on an anthropomorphic background, the use of image inversion produced significantly better results. No other significant differences were detected. CONCLUSION: Provided that the working environment is not bright, the results suggest that low-cost RD can be used for the recognition of low-contrast details in radiographies of the chest. Further studies including more display models are necessary. Among different ambient lighting and luminance settings, these studies should include a closer analysis of the special features of digital systems such as brightness/contrast adaptation, picture enlargement (zoom shot), and image inversion.

Equipment Design↗

Clinical features and biochemical data of Caucasian children at diagnosis of autoimmune hepatitis.

OBJECTIVE: Evaluation of systematic epidemiological data regarding clinical characteristics, sex distribution and autoantibody pattern in Caucasian children with autoimmune hepatitis (AIH). STUDY DESIGN: Data of 142 children presenting with AIH (97 girls and 45 boys) have been analysed for their clinical, serological, and histological profile. RESULTS: Clinical findings were jaundice (58%), unspecific weakness (57%), anorexia (47%), abdominal pain (38%) and paleness (26%). One hundred and three children (73%) (68 girls, 35 boys, 1.9:1) had AIH type 1 and 35 patients (25%) (27 girls, 8 boys, 3.4:1) type 2 due to specific autoantibodies. Four children could not be classified. Histology of 122 children revealed active hepatitis in 64 (52%), cirrhosis in 46 (38%), and mild inflammatory activity in 12 individuals (10%). The most prevalent HLA type was B8. CONCLUSION: In our cohort the prevalence of AIH was half as frequent in boys as in girls. Type 1 was the most frequent diagnosis (73%) and was more prevalent in older children. Type 2 was equally age distributed. The clinical presentation of AIH in children was unspecific and type I and type II could only be differentiated by the determination of the specific autoantibodies. Ninety percent of patients presented with high inflammatory activity or liver cirrhosis.

Adolescent↗

[The quality of digital mammograms. Development and use of phantoms for optimal safety].

Digital imaging in mammography is becoming more and more accepted using both computed (CR) and direct radiography (DR). These techniques will soon be used in screening programs. Therefore, quality assurance for this technique is indispensable. The relevance of the current regulations, such as EPOC and the German QS-RL was investigated. For the investigation, a breast phantom and appropriate software were developed. Both were tested using digital mammography systems from six manufactures. Quality assurance parameters (such as contrast to noise ratio and contrast resolution) were calculated from these data sets. The results should be considered in future standards for mammography (IEC respectively DIN). In addition, this type of test procedure is time saving and enables a reduction in test devices, i. e. in costs.

Breast Neoplasms↗

[3D ultrasound (3D US) in the diagnosis of focal breast lesions].

BACKGROUND: It was to analyse whether 3D breast US is able to enhance the diagnosis of focal breast lesions. MATERIAL AND METHODS: 60 patients were examined with 2D- and 3D US (GE logiq 9, 14 MHz). The solid lesions were analyzed by using the BIRADS classification. As standard of reference, histopathologic results were available in all cases. RESULTS: 38 malignant and 22 benign lesions were analyzed. With 2D US the sensitivity/specificity was 92/81%, with 3D US 97/72%, and by combination of 2D and 3D 97/81%. Characteristics of benign solid masses included a round or oval shape as well as clearly defined and sharply demarcated margins. CONCLUSIONS: 3D US allows to demonstrate breast masses in multiple planes. Distorsion of the surrounding soft tissues is an important sign indicative of malignancy.

Breast Neoplasms↗

[DRG and OPS-301: effects on the acquisition performance in radiology].

Reimbursement for inpatient services rendered based on comparable daily care rates, case-based flat rates, and special fees as practiced until now has been replaced by the system of diagnosis-related groups. Up until 2004, operation and procedure system (OPS 301) codes could be processed completely automatically by appropriate adaptation of the radiology information system (RIS). Because of further differentiation of OPS codes in the 2005 version, it is no longer possible to unambiguously determine OPS codes automatically. Our goal was to fulfill these additional requirements with as little extra effort as possible. In 36 of 2138 procedures during an observation period of 12 days, i.e., 4/day, manual input on the part of the radiology technical assistant and quality assurance by the diagnosing physician were necessary. This is only needed in complicated procedures for which the minor added effort is negligible in comparison to the entire effort expended for the procedure. We were thus able to achieve the goal of near automation of ascertaining OPS codes.

Databases, Factual↗

[PACS: storage and retrieval of digital radiological image data].

BACKGROUND: Efficient handling of both picture archiving and retrieval is a crucial factor when new PACS installations as well as technical upgrades are planned. MATERIALS AND METHODS: For a large PACS installation for 200 actual studies, the number, modality,and body region of available priors were evaluated. In addition, image access time of 100 CT studies from hard disk (RAID), magneto-optic disk (MOD), and tape archives (TAPE) were accessed. RESULTS: For current examinations priors existed in 61.1% with an averaged quantity of 7.7 studies. Thereof 56.3% were within 0-3 months, 84.9% within 12 months, 91.7% within 24 months, and 96.2% within 36 months. On average, access to images from the hard disk cache was more than 100 times faster then from MOD or TAPE. CONCLUSION: Since only PACS RAID provides online image access, at least current imaging of the past 12 months should be available from cache. An accurate prefetching mechanism facilitates effective use of the expensive online cache area. For that, however, close interaction of PACS, RIS, and KIS is an indispensable prerequisite.

Database Management Systems↗

[Possibilities for workflow optimization in radiology departments beyond RIS and PACS].

Technological progress and the rising cost pressure on the healthcare system have led to a drastic change in the work environment of radiologists today. The pervasive demand for workflow optimization and increased efficiency of its activities raises the question of whether by employment of electronic systems, such as RIS and PACS, the potentials of digital technology are sufficiently used to fulfil this demand. This report describes the tasks and structures in radiology departments, which so far are only insufficiently supported by commercially available electronic systems but are nevertheless substantial. We developed and employed a web-based, integrated workplace system, which simplifies many daily tasks of departmental organization and administration apart from well-established tasks of documentation. Furthermore, we analyzed the effects exerted on departmental workflow by employment of this system for 3 years.

Database Management Systems↗

[Digital teaching archive. Concept, implementation, and experiences in a university setting].

Film-based teaching files require a substantial investment in human, logistic, and financial resources. The combination of computer and network technology facilitates the workflow integration of distributing radiologic teaching cases within an institution (intranet) or via the World Wide Web (Internet). A digital teaching file (DTF) should include the following basic functions: image import from different sources and of different formats, editing of imported images, uniform case classification, quality control (peer review), a controlled access of different user groups (in-house and external), and an efficient retrieval strategy. The portable network graphics image format (PNG) is especially suitable for DTFs because of several features: pixel support, 2D-interlacing, gamma correction, and lossless compression. The American College of Radiology (ACR) "Index for Radiological Diagnoses" is hierarchically organized and thus an ideal classification system for a DTF. Computer-based training (CBT) in radiology is described in numerous publications, from supplementing traditional learning methods to certified education via the Internet. Attractiveness of a CBT application can be increased by integration of graphical and interactive elements but makes workflow integration of daily case input more difficult. Our DTF was built with established Internet instruments and integrated into a heterogeneous PACS/RIS environment. It facilitates a quick transfer (DICOM_Send) of selected images at the time of interpretation to the DTF and access to the DTF application at any time anywhere within the university hospital intranet employing a standard web browser. A DTF is a small but important building block in an institutional strategy of knowledge management.

Computer-Assisted Instruction↗

[Recommendations for the selection of storage media for archiving digital radiological image data based on the comparison of retrieval times at different PACS archive levels].

PURPOSE: Recommendations for archiving digital radiological image data based on the comparison of retrieval times for different PACS archive levels. MATERIALS AND METHODS: For a large PACS installation (Agfa Impax, Release 4.1), image retrieval times for radiological standard examinations (chest radiographs with 2, MRI with 250, CT with 100 and 1000 images; n = 120, each) from hard disk array, magneto-optical disk (MOD), and magnetic tape archives (TAPE) were examined in high and low network traffic load. RESULTS: Even large CT examinations (1000 images) were available from hard disk arrays within 4.0 +/- 0.8 s, smaller studies within 1.8 +/- 0.3 s. Radiographic image retrieval from MOD (30 +/- 4.7 s) was more then 50 % faster than from TAPE. For typical cross-sectional studies, the velocity gain amounted to 19 %. For both technologies, no significant difference was found for large CT examinations (651 +/- 144 s). For high and low network traffic load scenarios, image retrieval times from hard disk, MOD, and TAPE archives increased by 87 %, 7 %, and 22 %, respectively. CONCLUSION: Hard disk arrays are specifically suited as departmental intermediate storage media because they allow fast access to current and previous examinations within a short time. Performance properties enable both MOD and TAPE systems to serve as long-term archives. However, MOD archives are less flexible in the expansion of storage capacity and at present the medium costs per memory unit are about 2 - 3 times higher than for tape archives. The use of existing MOD-archives may be adequate as intermediate archives. For new PACS installations or system expansions, however, it is recommended to combine a sufficiently large local data memory (RAID) with data storage on tape archives outside the radiological unit that can be used by other departments as well. Future development of hard disk prices will show whether archiving for the whole data retention period may be handled by RAID systems. In any case, prefetching problems and waiting periods for demanded pre-studies would not occur any more.

Humans↗

Initial clinical results with a new needle screen storage phosphor system in chest radiograms.

PURPOSE: To evaluate image quality and anatomical detail depiction in dose-reduced digital plain chest radiograms using a new needle screen storage phosphor (NIP) in comparison to full dose conventional powder screen storage phosphor (PIP) images. MATERIALS AND METHODS: 24 supine chest radiograms were obtained with PIP at standard dose and compared to follow-up studies of the same patients obtained with NIP with dose reduced to 50 % of the PIP dose (all imaging systems: AGFA-Gevaert, Mortsel, Belgium). In both systems identical versions of post-processing software supplied by the manufacturer were used with matched parameters. Six independent readers blinded to both modality and dose evaluated the images for depiction and differentiation of defined anatomical regions (peripheral lung parenchyma, central lung parenchyma, hilum, heart, diaphragm, upper mediastinum, and bone). All NIP images were compared to the corresponding PIP images using a five-point scale (- 2, clearly inferior to + 2, clearly superior). Overall image quality was rated for each PIP and NIP image separately (1, not usable to 5, excellent). RESULTS: PIP and dose reduced NIP images were rated equivalent. Mean image noise impression was only slightly higher on NIP images. Mean image quality for NIP showed no significant differences (p > 0.05, Mann-Whitney U test). CONCLUSION: With the use of the new needle structured storage phosphors in chest radiography, dose reduction of up to 50 % is possible without detracting from image quality or detail depiction. Especially in patients with multiple follow-up studies the overall dose can be decreased significantly.

Adult↗

IT services in a completely digitized radiological department: value and benefit of an in-house departmental IT group.

To analyze the benefit of a departmental IT group in comparison to support by hospital IT groups or system manufacturers in a completely digitized radiological department. The departmental IT group comprises a fulltime IT specialist, two student assistants and four clinical employees participating 1 day/week. For 18 months IT problems were quantified and specified according to urgency, responsibility and affected system by use of an intranet-based reporting system. For each IT service provider the performance and duration of problem solution was evaluated. In 18 months 3,234 IT problems emerged. 88.7% were solved by the departmental IT group. In 474 cases (14.7%) a solution within 2 h was required. The departmental IT group solved 35.8% within 30 min, system manufacturers needed 18 h 38 min in mean. The departmental IT group solved 90.2% of the problems within a time limit. System manufacturers met the limit in 60.1% with a mean duration of 7 days 21 h. In 6.7% of the cases, support by system manufacturers was indispensable. A considerable proportion of IT problems in completely digitized radiological departments can be solved by a departmental IT group, providing a fast and cost-efficient first-level IT support with effective prevention of major breaks in the workflow. In a small number of cases support by system manufacturers remains necessary.

Computer Communication Networks↗