PubMed Health⌕ Search

Biomedical subjects

S Wishu

Publications and source records attributed to S Wishu.

9 recordsLinked to original sources

High-performance liquid chromatography method for the quantification of entacapone in human plasma.

A simple, sensitive and selective HPLC method with UV detection (315 nm) was developed and validated for quantitation of entacapone in human plasma, the newest addition to the group of antiparkinsonian agents. Following a single-step liquid-liquid extraction (LLE) with ethyl acetate/n-hexane (30/70, v/v), the analyte and internal standard (rofecoxib) were separated using an isocratic mobile phase of 30 mM phosphate buffer (pH 2.75)/acetonitrile (62/38, v/v) on a reverse phase C18 column. The lower limit of quantitation was 25 ng/mL, with a relative standard deviation of less than 8%. A linear range of 25-2500 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 2.2-4.2% and 1.7-7.8%, respectively. The between-batch and within-batch accuracy was 98.7-107.5% and 97.5-106.0%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of entacapone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.

Administration, Oral↗

High-performance liquid chromatography method for the quantification of pantoprazole in human plasma.

A sensitive and selective HPLC method with UV detection (290 nm) was developed and validated for quantitation of pantoprazole, proton-pump inhibitor, in human plasma. Following a single-step liquid-liquid extraction with methyl tert-butyl ether/diethyl ether (70/30, v/v), the analyte and internal standard (zonisamide) were separated using an isocratic mobile phase of 10mM phosphate buffer (pH 6.0)/acetonitrile (61/39, v/v) on reverse phase Waters symmetry C18 column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 4%. A linear range of 20-5000 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 1.3-3.2% and 0.7-3.3%, respectively. The between-batch and within-batch bias was -0.5 to 8.2 % and -2.5 to 12.1%, respectively. This validated method is sensitive and repeatable enough to be used in pharmacokinetic studies.

2-Pyridinylmethylsulfinylbenzimidazoles↗

High-performance liquid chromatography method for the quantification of rabeprazole in human plasma using solid-phase extraction.

A simple, sensitive and selective HPLC method with UV detection (284 nm) was developed and validated for quantitation of rabeprazole in human plasma, the newest addition to the group of proton-pump inhibitors. Following solid-phase extraction using Waters Oasistrade mark SPE cartridges, the analyte and internal standard (Pantoprazole) were separated using an isocratic mobile phase of 5 mM ammonium acetate buffer (pH adjusted to 7.4 with sodium hydroxide solution)/acetonitrile/methanol (45/20/35, v/v) on reverse phase Waters symmetry C(18) column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 8%. A linear range of 20-1000 ng/mL was established. This HPLC method was validated with between- and within-batch precision of 2.4-7.2% and 2.2-7.3%, respectively. The between- and within-batch bias was -1.7 to 2.6% and -2.6 to 2.1%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of rabeprazole in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 3 months storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.

2-Pyridinylmethylsulfinylbenzimidazoles↗

Validated liquid chromatographic ultraviolet method for the quantitation of Etoricoxib in human plasma using liquid-liquid extraction.

A simple, sensitive and specific HPLC method with UV detection (284 nm) was developed and validated for quantitation of Etoricoxib in human plasma, the newest addition to the group of nonsteroidal anti-inflammatory drugs-a highly selective cyclooxygenase-2 inhibitor. Following a single-step liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v), the analyte and internal standard (Zaleplon) were separated using an isocratic mobile phase of water/acetonitrile (58/42, v/v) on reverse phase Waters symmetry C(18) column. The lower limit of quantitation was 5 ng/mL, with a relative standard deviation of less than 20%. A linear range of 5-2500 ng/mL was established. This HPLC method was validated with between- and within-batch precision of 4.1-5.1% and 1.1-2.4%, respectively. The between- and within-batch bias was -3.8-4.7% and -0.6-9.4%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of Etoricoxib in plasma was >90%, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is sensitive and simple with between-batch precision of <6% and was used in pharmacokinetic studies.

Chromatography, High Pressure Liquid↗

Rapid, simple and highly sensitive LC-ESI-MS/MS method for the quantification of tamsulosin in human plasma.

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tamsulosin (I), a highly selective alpha1-adrenoceptor antagonist used for the treatment of patients with symptomatic benign prostatic hyperplasia. The analyte and internal standard, mosapride (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Waters symmetry C18 column with a mobile phase of 0.03% formic acid-acetonitrile (30:70, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 409.1 solidus in circle 228.1 and m/z 422.3 solidus in circle 198.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-50.0 ng/mL for tamsulosin in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Adrenergic alpha-Antagonists↗

Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma.

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Antidiuretic Agents↗

Quantitation of tadalafil in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionization.

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantitation of tadalafil (I) in human plasma, a new selective, reversible phosphodiesterase 5 inhibitor. The analyte and internal standard (sildenafil, II) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (10/90, v/v, pH adjusted to 3.0 with formic acid). The protonate of analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 390.4 --> 268.0 and m/z 475.5 --> 58.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-1000 ng/mL for tadalafil in human plasma. The lower limit of quantitation was 10 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Calibration↗

Liquid chromatography-negative ion electrospray tandem mass spectrometry method for the quantification of tacrolimus in human plasma and its bioanalytical applications.

A simple, rapid, novel and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tacrolimus (I) in human plasma, a narrow therapeutic index, potent macrolide immunosuppressive drug. The analyte and internal standard (tamsulosin (II)) were extracted by liquid-liquid extraction with t-butylmethylether using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra ODS column with a mobile phase of 99% methanol and 1% 10mM ammonium acetate buffer. The deprotonate of analyte was quantitated in negative ionization by multiple reaction monitoring (MRM) with a mass spectrometer. The mass transitions m/z 802.5-->560.3 and m/z 407.2-->151.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.05-25ng/ml for tacrolimus in human plasma. The lower limit of quantitation was 50pg/ml with a relative standard deviation of less than 20%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 2min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in comparative bioavailability studies. The tacrolimus plasma concentration profile could be obtained for pharmacokinetic study. The observed maximum plasma concentration (C(max)) of tacrolimus (5mg oral dose) is 440pg/ml, time to observed maximum plasma concentration (T(max)) is 2.5h and elimination half-life (T(1/2)) is 21h.

Biological Availability↗

Quantitation of Valdecoxib in human plasma by high-performance liquid chromatography with ultraviolet absorbance detection using liquid-liquid extraction.

A simple, sensitive and specific HPLC method with UV detection (210 nm) was developed and validated for quantitation of Valdecoxib in human plasma, the newest addition to the group of non-steroidal anti-inflammatory drugs-a highly selective cyclooxygenase-2 inhibitor. The analyte and an internal standard (Rofecoxib) were extracted with diethyl ether/dichloromethane (70/30 (v/v)). The chromatographic separation was performed on reverse phase ODS-AQ column with an isocratic mobile phase of water/methanol (47/53 (v/v)). The lower limit of quantitation was 10 ng/ml, with a relative standard deviation of <20%. A linear range of 10-500 ng/ml was established. This HPLC method was validated with between-batch and within-batch precision of 1.27-7.45 and 0.79-6.12%, respectively. The between-batch and within-batch bias was 0.74-7.40 and -0.93 to 7.70%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of Valdecoxib in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is suitable for bioequivalence studies following single dose in healthy volunteers.

Chromatography, High Pressure Liquid↗