The influence of viscosity on the shear strain remotely induced by focused ultrasound in viscoelastic media.

Shear wave elasticity imaging (SWEI), an emerging acoustic technology for medical diagnostics, is based on remote generation of shear waves in tissue by radiation force in the focal region of an ultrasonic beam. In this study, the feasibility of Doppler ultrasonic technique to visualize the remotely induced shear waves was demonstrated. The generation of shear displacement in the focal region of a pulsed 1-MHz ultrasound beam with pulse duration of approximately about 2 ms and intensity levels on the order of 145 W/cm2, and consequent propagation of shear wave in tissue-mimicking and muscle tissue in vitro, were measured. The analysis of temporal behavior of shear displacement within the focal plane allowed estimation of shear wave velocities. The velocities were 4 and 7 m/s in hard phantom and tissue containing phantom, respectively. The measured shear displacements on the order of micrometers in gel-based phantoms are in reasonable agreement with theoretical estimates derived from an earlier developed model of shear wave generation by radiation force of focused ultrasound. The study revealed significant dependence of shear strain on the medium viscosity. The complex oscillatory character of shear strain relaxation in viscoelastic phantom and muscle tissue in vitro was observed.

Animals↗

Doppler ultrasound detection of shear waves remotely induced in tissue phantoms and tissue in vitro.

In shear wave elasticity imaging (SWEI), mechanical excitation within the tissue is remotely generated using radiation force of focused ultrasound. The induced shear strain is subsequently detected to estimate visco-elastic properties of tissue and thus aid diagnostics. In this paper, the mechanical response of tissue to radiation force was detected using a modified ultrasound Doppler technique. The experiments were performed on tissue mimicking and tissue containing phantoms using a commercial diagnostic scanner. This scanner was modified to control both the pushing and probing beams. The pushing beam was fired repetitively along a single direction while interlaced probing beams swept the surrounding region of interest to detect the induced motion. The detectability of inhomogeneous inclusions using ultrasonic Doppler SWEI method has been demonstrated in this study. The displacement fields measured in elastic phantoms clearly reveal the oscillatory nature of the mechanical relaxation processes in response to impulsive load due to the boundary effects. This relaxation dynamics was also present in cooked muscle tissue, but was not detected in more viscous and less elastic phantom and raw muscles. Presence of a local heterogeneity in the vicinity of the focal region of the pushing beam results in generation of a standing wave field pattern which is manifested in the oscillatory response of the excited region of the tissue. There has been made an assumption that dynamic characteristics of the relaxation process may be used for visualization of inhomogeneities.

Animals↗

Triplex ultrasound: elasticity imaging to age deep venous thrombosis.

Deep venous thrombosis (DVT), and its sequela, pulmonary embolism (PE), is the leading cause of preventable in-hospital mortality in the USA and other developed countries. After it is detected, acute clots must be differentiated from chronic DVT for appropriate treatment. However, there are no reliable thrombus staging methods presently available in clinical practice. In this study, we tested the hypothesis that blood clots can be detected and staged using a triplex ultrasound (US) test. Triplex US is based on a "gold standard" duplex US technique augmented by US-based reconstructive elasticity imaging. Fibrin-composed blood clots harden with development and organization. By imaging clot elasticity, it may be possible to both detect and differentiate clots and, therefore, provide an urgently needed noninvasive means of DVT staging.

Animals↗

Strain rate imaging using two-dimensional speckle tracking.

Strain rate images (SRI) of the beating heart have been proposed to identify non-contracting regions of myocardium. Initial attempts used spatial derivatives of tissue velocity (Doppler) signals. Here, an alternate method is proposed based on two-dimensional phase-sensitive speckle tracking applied to very high frame rate, real-time images. This processing can produce high resolution maps of the time derivative of the strain magnitude (i.e., square root of the strain intensity). Such images complement traditional tissue velocity images (TVI), providing a more complete description of cardiac mechanics. To test the proposed approach, SRI were both simulated and measured on a thick-walled, cylindrical, tissue-equivalent phantom modeling cardiac deformations. Real-time ultrasound images were captured during periodic phantom deformation, where the period was matched to the data capture rate of a commercial scanner mimicking high frame rate imaging of the heart. Simulation results show that SRI with spatial resolution between 1 and 2 mm are possible with an array system operating at 5 MHz. Moreover, these images are virtually free of angle-dependent artifacts present in TVI and simple strain rate maps derived from these images. Measured results clearly show that phantom regions of low deformation, which are difficult to identify on tissue velocity-derived SRI, are readily apparent with SRI generated from two-dimensional phase-sensitive speckle tracking.

Biomedical Engineering↗

Three-dimensional static displacement, stimulated echo NMR elasticity imaging.

This article presents a method for measuring three-dimensional mechanical displacement and strain fields using stimulated echo MRI. Additional gradient pulses encode internal displacements in response to an externally applied deformation. By limiting the mechanical transition to the stimulated echo mixing time, a more accurate static displacement measurement is obtained. A three-dimensional elasticity reconstruction within a region of interest having a uniform shear modulus along its boundary is performed by numerically solving discretized elasticity equilibrium equations. Data acquisition, strain measurements and reconstruction were performed using a silicone gel phantom containing an inclusion of known elastic properties. A comparison between two-dimensional and three-dimensional reconstructions from simulated and experimental displacement data shows higher accuracy from the three-dimensional reconstruction. The long-term objective of this work is to provide a method for remotely palpating and elastically quantitating manually inaccessible tissues.

Echocardiography↗

Reconstructive ultrasound elasticity imaging for renal transplant diagnosis: kidney ex vivo results.

It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticity can be imaged using a clinical ultrasound scanner was experimentally tested with an ex vivo canine kidney model, and results on a single pair of kidneys are reported in this paper. A cross-linking agent affected kidney elasticity both globally and locally. Elasticity changes were monitored with accurate estimates of internal displacement and strain followed by Young's modulus reconstruction. The results of this study strongly suggest that ultrasound elasticity imaging can detect elasticity changes in complex structures such as the kidney. Moreover, it has the potential to become an important clinical tool for renal transplant diagnosis.

Animals↗

Elasticity reconstructive imaging by means of stimulated echo MRI.

A method is introduced to measure internal mechanical displacement and strain by means of MRI. Such measurements are needed to reconstruct an image of the elastic Young's modulus. A stimulated echo acquisition sequence with additional gradient pulses encodes internal displacements in response to an externally applied differential deformation. The sequence provides an accurate measure of static displacement by limiting the mechanical transitions to the mixing period of the simulated echo. Elasticity reconstruction involves definition of a region of interest having uniform Young's modulus along its boundary and subsequent solution of the discretized elasticity equilibrium equations. Data acquisition and reconstruction were performed on a urethane rubber phantom of known elastic properties and an ex vivo canine kidney phantom using <2% differential deformation. Regional elastic properties are well represented on Young's modulus images. The long-term objective of this work is to provide a means for remote palpation and elasticity quantitation in deep tissues otherwise inaccessible to manual palpation.

Algorithms↗

Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Shear wave elasticity imaging (SWEI) is a new approach to imaging and characterizing tissue structures based on the use of shear acoustic waves remotely induced by the radiation force of a focused ultrasonic beam. SWEI provides the physician with a virtual "finger" to probe the elasticity of the internal regions of the body. In SWEI, compared to other approaches in elasticity imaging, the induced strain in the tissue can be highly localized, because the remotely induced shear waves are attenuated fully within a very limited area of tissue in the vicinity of the focal point of a focused ultrasound beam. SWEI may add a new quality to conventional ultrasonic imaging or magnetic resonance imaging. Adding shear elasticity data ("palpation information") by superimposing color-coded elasticity data over ultrasonic or magnetic resonance images may enable better differentiation of tissues and further enhance diagnosis. This article presents a physical and mathematical basis of SWEI with some experimental results of pilot studies proving feasibility of this new ultrasonic technology. A theoretical model of shear oscillations in soft biological tissue remotely induced by the radiation force of focused ultrasound is described. Experimental studies based on optical and magnetic resonance imaging detection of these shear waves are presented. Recorded spatial and temporal profiles of propagating shear waves fully confirm the results of mathematical modeling. Finally, the safety of the SWEI method is discussed, and it is shown that typical ultrasonic exposure of SWEI is significantly below the threshold of damaging effects of focused ultrasound.

Acoustics↗

Measuring the elastic modulus of small tissue samples.

Independent measurements of the elastic modulus (Young's modulus) of tissue are necessary step in turning elasticity imaging into a clinical tool. A system capable of measuring the elastic modulus of small tissue samples was developed. The system tolerates the constraints of biological tissue, such as limited sample size (< or = 1.5 cm3) and imperfections in sample geometry. A known deformation is applied to the tissue sample while simultaneously measuring the resulting force. These measurements are then converted to an elastic modulus, where the conversion uses prior calibration of the system with plastisol samples of known Young's modulus. Accurate measurements have been obtained from 10 to 80 kPa, covering a wide range of tissue modulus values. In addition, the performance of the system was further investigated using finite element analysis. Finally, preliminary elasticity measurements on canine kidney samples are presented and discussed.

Animals↗

Strain imaging of coronary arteries with intraluminal ultrasound: experiments on an inhomogeneous phantom.

In coronary arteries, knowing the relative stiffness of atherosclerotic lesions can help physicians select the most appropriate therapeutic modality. Because soft material supports larger strains than hard, measurements of this quantity can distinguish tissue of differing stiffness. In a previous paper, we described techniques for computing displacements and strains in coronary arteries using an integrated angioplasty and imaging catheter. Here, we demonstrate that hard and soft materials in a tissue-mimicking phantom can be differentiated with this device. Because tissue motion cannot be distinguished from catheter motion a priori, we perform all computations in the coordinate system centered at the balloon's geometric center. This reference frame depends only on balloon shape and is independent of catheter motion. A specialized correlation-based, phase-sensitive speckle tracking algorithm has been developed to compute strain. Maximum phantom displacement was about 25 microns, and the maximum radial, normal strain was about 1.5 percent.

Catheterization↗

Elasticity imaging for early detection of renal pathology.

Early detection of renal pathology may be possible with elasticity imaging. This hypothesis was experimentally tested by quantitatively imaging internal mechanical strain due to surface deformations in an in vitro animal model of nephritis. Preliminary data support the hypothesis that kidney elasticity changes with renal damage and concomitant scarring before problems are detectable by traditional diagnostic techniques such as laboratory measurements of renal function.

Animals↗

Magnetic-resonance imaging techniques for detection of elasticity variation.

The relative success of manual palpation in the detection of breast cancer would suggest that a method for remote palpation resulting in a measurement of tissue elasticity could provide a diagnostic tool for detecting cancerous lesions deeper within the breast. This presumption is based in part on the excellent contrast between neoplastic and normal tissue due to the large (orders of magnitude) relative variation in the shear elastic modulus. By comparison, the bulk deformational modulus maintains the same value to within 20% for most soft tissues. A specific method of magnetic-resonance imaging (MRI) which measures tissue displacements has been used in experiments with a phantom containing regions of increased Young's modulus as a demonstration. The spatial modulation of magnetization technique uses the displacement of a spatial grid pattern caused by spin saturation to track regional motion. Mathematical reconstruction of the distribution of elastic moduli is shown for select examples. Any modality, e.g., MRI, ultrasound, etc., which can detect local tissue motion with sufficient spatial resolution can be used and therefore the results presented here should give an indication of the utility of such motion tracking techniques to future measurement of tissue elasticity.