Multiple adverse events with a dual chamber pacemaker.

The aim of the study was to evaluate our experience with Physiocor 400T, a dual chamber unipolar pacemaker manufactured by Sorin Biomedica. Between March 1993 and December 1994, 63 units of that model were implanted at our center. Patients were followed for 46 +/- 16 months. By the end of follow-up, 15 patients had died, 1 patient was lost to follow-up, and two units had been replaced for unrelated reasons. During follow-up the following phenomena had been observed: (1) Spontaneous backup reversion (VOO, 80 ppm) in 6 (9.5%) of 63 patients. In three patients this phenomenon was accompanied by concomitant ineffective pacing artifacts at 130 beats/min with very low pulse widths. (2) Unexpected battery depletion (EOL) occurred in 3 (5%) of 63 patients; two of the three occurred within weeks of routine evaluation that confirmed normal battery status. (3) Early elective replacement time (ERT) unpreceded by a gradual drop in magnet rate in 2 (3.2%) of 63 patients. (4) Total loss of telemetry without change in pacing mode in 1 (1.6%) of 63 patients. The estimated event-free 5-year survival of this model was 46%. In conclusion, 12 (19%) of 63 patients had adverse events with Physiocor 400T pacemakers. The potential risk of asynchronous pacing for prolonged periods and the risk of unexpected EOL warrants consideration of elective replacement of all remaining units.

Adolescent↗

Randomized comparison of J-shaped and straight atrial screw-in pacing leads.

OBJECTIVE: To study the importance of a J shape in atrial pacing leads. PATIENTS AND METHODS: We compared in a randomized controlled study acute and chronic results with 2 steroid-eluting, polyurethane, screw-in atrial lead models that differ only in shape. A total of 208 patients were randomized to have implantation of either a straight atrial lead (n = 105) or a J-shaped atrial lead (n = 103). Patients were followed up for 1 year. RESULTS: On implantation, there were no significant differences between leads in rates of failure to implant, implant measurements, number of attempts to achieve an acceptable position, and fluoroscopy times. Before discharge and at 3-month and 1-year follow-up, electrical measurements showed no statistical differences between leads. During the first year after implantation, there were 2.9% early dislodgments (< 1 week after implantation) and 2.9% late dislodgments in the straight lead group (5.9% rate of all dislodgments) vs no dislodgments in the J-shaped lead group (P = .01). There was a trend toward higher rates of exit block and lead malfunction in the J-shaped lead group. Rates of pericardial complications, subclavian/axillary thrombosis, and chronic atrial fibrillation were the same in both groups. CONCLUSIONS: Both leads appear to have an equally favorable performance profile for 1 year of follow-up. The J-shaped lead seems to be more stable and have fewer dislodgments, although it may have a somewhat higher malfunction rate.

Adult↗