PubMed Health⌕ Search

Biomedical subjects

Séverine Le Gac

Publications and source records attributed to Séverine Le Gac.

7 recordsLinked to original sources

Quantum dots based probes conjugated to annexin V for photostable apoptosis detection and imaging.

Quantum dots (Qdots) are nanoparticles exhibiting fluorescent properties that can be used for cell staining. We present here the development of quantum dots conjugated to Annexin V for specific targeting of apoptotic cells, for both apoptosis detection and staining of apoptotic "living" cells. For that purpose, Qdots Streptavidin Conjugates are coupled to biotinylated Annexin V, a 35-kDa protein which specifically recognizes and binds to phosphatidylserine (PS) moieties present on the outer membrane of apoptotic cells and not on healthy or necrotic cells. By using Annexin V, our Qdots probes are made specific for apoptotic cells. Staining of apoptotic cells was checked using fluorescence and confocal microscopy techniques and nonfixed cells. It is shown here that Qdots are insensitive to bleaching after prolonged exposure as opposed to organic dyes. This makes Qdots excellent candidates to continuously follow fast changes occurring at the membrane of apoptotic cells and facilitates time-lapse imaging as they alleviate any bleaching issue.

Annexin A5↗

An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage.

This paper describes a novel emitter tip having the shape of a nib and based on an open structure for nano-electrospray ionization mass spectrometry (nanoESI-MS). The nib structure is fabricated with standard lithography techniques using SU-8, an epoxy-based negative photoresist. The tip is comprised of a reservoir, a capillary slot and a point-like feature, and is fabricated on a silicon wafer. We present here a novel scheme for interfacing such nib tips to MS by applying the ionization voltage directly onto the semi-conductor support. The silicon support is in direct contact with the liquid to be analyzed at the reservoir and microchannel level, thus allowing easy use in ESI-MS. This scheme is especially advantageous for automated analysis as the manual step of positioning a metallic wire into the reservoir is avoided. In addition, the analysis performance was enhanced compared with the former scheme, as demonstrated by the tests of standard peptides (gramicidin S, Glu-fibrinopeptide B). The limit of detection was determined to be lower than 10(-2) microM. Due to their enhanced performance, these microfabricated sources might be of great interest for analysis requiring very high sensitivity, such as proteomics analysis using nanoESI-MS.

Journal Article↗

Integrated microfabricated systems including a purification module and an on-chip nano electrospray ionization interface for biological analysis.

We report here on an integrated microfabricated device dedicated to the preparation of biological samples prior to their on-line analysis by electrospray ionization-mass spectrometry (ESI-MS). This microfluidic device is fabricated using the negative photoresist SU-8 by microtechnology techniques. The device includes a chromatographic module plus an ESI interface for MS. The chromatographic module is dedicated to sample purification and is based on a polymer monolithic phase which includes hydrophobic moieties. The ESI interface is integrated onto the chip and is based on a capillary slot. We present here the integration of these different modules onto a single system that is fabricated via a SU-8-based microtechnology route. We present also their testing for the purification of peptide samples. This started with a partial integration step with the combination of at least two of the modules (microsystem + monolith; microsystem + nib) and their test before the fabrication and testing of fully integrated microsystems.

Microscopy, Electron, Scanning↗

Monoliths for microfluidic devices in proteomics.

We report here on the preparation of monolithic capillary columns in view to their integration in a microsystem for on-chip sample preparation before their on-line analysis by electrospray and mass spectrometry (ESI-MS). These monolithic columns are based on polymer materials and consist of reverse phases for peptide separation and/or desalting. They were prepared using lauryl methacrylate (LMA), ethylene dimethacrylate (EDMA) as well as a suitable porogenic mixture composed of cyclohexanol and ethylene glycol. The resulting stationary phases present thus a C12-functionality. The LMA-based columns were first prepared in a capillary format using capillary tubing of 75 microm i.d. and tested in nanoLC-MS experiments for the separation of a commercial Cytochrome C digest composed of 12 peptidic fragments whose isoelectric point values and hydrophobic character cover a wide range. The LMA-based columns were capable of separating the peptidic fragments and their performances were seen to be similar as those of standard commercial columns dedicated to proteomic purposes with calculated separation efficiencies up to 145 x 10(3) plates/m. Monolithic LMA-based phases were then successfully polymerized in microchannels fabricated using the negative photoresist SU-8. After the polymerization, the systems were seen to withstand the pressures applied during the nanoLC-MS separation tests that were carried out in the same conditions as for the monolithic capillary columns. The pressure drop during these tests of the in-microchannel monoliths was as high as 50 bar; however, the separation was not as good as for a capillary format which could be accounted for by the monolith dimensions.

Amino Acid Sequence↗

A novel nib-like design for microfabricated nanospray tips.

We present here novel tips for nanoelectrosray ionization-mass spectrometry (ESI-MS) applications. These ionization sources have a planar geometry in the shape of a nib. Their functioning is based on a principle much akin to that of a fountain pen in that fluids are actuated by capillarity. Once a voltage is applied, an electrospray is formed at the nib tip. The nib fabrication relies on micromachining techniques using the epoxy-based negative photoresist SU-8 and a double exposure photolithographic process. Two types of nib-like sources were fabricated; they were made either conductive by metallization with a nickel layer or non-conductive but hydrophilic by covering them with a SiO(2) layer. In the latter case, the HV was applied via a Pt wire inserted into the reservoir feature of the nib. The nib-like sources were tested on an ion trap mass spectrometer using Gramicidin S samples at concentrations as low as 1 microM and ionization voltages as low as 1.2 kV. We have observed a good overall stability of the spray during the tests with no marked decrease in the signal intensity even under extreme conditions.

Journal Article↗

A planar microfabricated nanoelectrospray emitter tip based on a capillary slot.

We report on the fabrication and testing of planar nib-like structures for nanoelectrospray ionization-mass spectrometry (nanoESI-MS) applications. The micro-nib structures were fabricated on silicon substrates using the negative photoresist SU-8; they include capillary slots with widths of 8 and 16 microm. A suitable wafer cleaving step made the nib-like structures overhang the edge of a silicon substrate to provide a robust interface for nanoESI-MS applications; this freeing of the nib tip from the wafer surface created a point-like structure that is essential to establish an electrospray. The micro-nib sources were successfully tested on an LCQ Deca XP+ ion trap mass spectrometer using peptide samples at concentrations down to 1 microM. The high voltage was applied using a platinum wire inserted in the sample reservoir upstream to the capillary slot. A Taylor cone was clearly seen at the nib tip. The micro-nibs performed well at voltages as low as 0.8 kV; such performances are state-of-the-art with respect to current micromachined ESI-MS interfaces and are conditions comparable to those used for standard emitter tips. In addition, we clearly observed the influence of the micro-nib slot width on the ionization performances: the narrower the slot, the better the performances.

Gramicidin↗

Two-dimensional microfabricated sources for nanoelectrospray.

The idea of a novel two-dimensional (2D) nanoelectrospray ionization emitter tip with the shape of a nib is explored here. This novel planar design is studied as an alternative to the needle-like standard emitter tips that suffer from a lack of reproducibility and robustness and from an inherent incompatibility with high-throughput analysis. The composition of the micro-nib sources is analogous to the working of a simple fountain pen, with a liquid reservoir linked to a micro-nib tip from which the sample is electrosprayed via a capillary slot. The micro-nib prototypes described here were fabricated using microtechnology techniques and using the epoxy-based negative photoresist SU-8. The resulting free-standing micro-nib structure was supported by a silicon wafer. We present here two series of such micro-nib sources, the latter series exhibiting improved characteristics such as a 8 micro m source width of the nib tip. They were tested in mass spectrometry experiments on an ion trap mass spectrometer (LCQ Deca XP+, Thermo Finnigan) using standard peptide samples having concentrations down to 1 micro M and with a high voltage (HV) supply around 1 kV for the second series of micro-nib sources. In addition to the stability of the spray, the obtained mass spectra showed the reliability of these sources for peptide analysis; the signal of the spectra was as intense and the signal-to-noise ratio (S/N) as high as that obtained with the use of standard emitter tips.

Gramicidin↗