Angiographic views used for percutaneous coronary interventions: a three-dimensional analysis of physician-determined vs. computer-generated views.

The goal of this study was to determine the severity of vessel foreshortening in standard angiographic views used during percutaneous coronary intervention (PCI). Coronary angiography is limited by its two-dimensional (2D) representation of three-dimensional (3D) structures. Vessel foreshortening in angiographic images may cause errors in the assessment of lesions or the selection and placement of stents. To date, no technique has existed to quantify these 2D limitations or the performance of physicians in selecting angiographic views. Stent deployment was performed in 156 vessel segments in 149 patients. Using 3D reconstruction models of each patient's coronary tree, vessel foreshortening was measured in the actual working view used for stent deployment. A computer-generated optimal view was then identified for each vessel segment and compared to the working view. Vessel foreshortening ranged from 0 to 50% in the 156 working views used for stent deployment and varied by coronary artery and by vessel segment within each artery. In general, views of the mid circumflex artery were the most foreshortened and views of the right coronary artery were the least foreshortened. Expert-recommended views frequently resulted in more foreshortening than computer-generated optimal views, which had only 0.5% +/- 1.2% foreshortening with < 2% overlap for the same 156 segments. Optimal views differed from the operator-selected working views by > or = 10 degrees in over 90% of vessels and frequently occurred in entirely different imaging quadrants. Vessel foreshortening occurs frequently in standard angiographic projections during stent deployment. If unrecognized by the operator, vessel foreshortening may result in suboptimal clinical results. Modifications to expert-recommended views using 3D reconstruction may improve visualization and the accuracy of stent deployment. These results highlight the limitations of 2D angiography and support the development of real-time 3D techniques to improve visualization during PCI.

Adult↗

Three-dimensional vascular angiography.

Traditional angiography of the vasculature is limited by its 2-dimensional projection of complex 3-dimensional structures and the consequent imaging artifacts that interfere with visualization. During the last 10 years, technologies capable of minimizing the shortcomings of traditional angiography have been developed and are now in clinical use. Rotational angiography and 3-dimensional imaging are 2 of these powerful tools and, together, represent a major advance in the angiographic diagnosis and treatment of patients with coronary, cerebral, and peripheral vascular disease.

Cardiovascular Diseases↗

Four-dimensional analysis of cyclic changes in coronary artery shape.

The objective of this study was to derive a method for quantifying the dynamic geometry of coronary arteries. Coronary artery geometry plays an important role in atherosclerosis. Coronary artery geometry also influences the performance of coronary interventions. Conversely, implantation of stents may alter coronary artery geometry. Clinical tools to define vessel shape have not been readily available. Using a Frenet-Serret curvature analysis applied to 3D reconstruction data derived from standard coronary angiograms, 21 coronary arteries were analyzed at end-diastole (ED) and end-systole (ES). Vessels were divided anatomically: type 1 consisted of vessels lying in the AV groove (left circumflex, right coronary) and type 2 consisted of vessels overlying actively contracting myocardium (left anterior descending, diagonal, obtuse marginal, right ventricular marginal, posterior descending, posterolateral). Vessel segments were analyzed by assessing the changes in curvature, torsion, and discrete flexion points (FPs), areas of systolic bending in the arterial contour. The curvature from ED to ES of type 1 vessels was unchanged (-0.02 +/- 0.03 cm(-1)), while the curvature change of type 2 vessels showed a 38% increase (0.33 +/- 0.04 cm(-1); P < 0.001). Type 1 vessels had fewer FPs per vessel than type 2 vessels (0.38 +/- 0.18 and 2.40 +/- 0.23 FP/vessel, respectively; P < 0.001). FPs were more common in distal segments and branch vessels. A method to quantify cyclic changes in coronary artery shape was applied to 3D data sets derived from standard coronary angiograms. Coronary arteries undergo a cyclic change in shape resulting in changes in overall curvature as well as formation of discrete flexion points. These changes in vessel shape are asymmetrically distributed in coronary arteries.

Coronary Angiography↗