PubMed Health⌕ Search

Biomedical subjects

SD Sommerfeldt

Publications and source records attributed to SD Sommerfeldt.

2 recordsLinked to original sources

Narrowband and broadband active control in an enclosure using the acoustic energy density

An active control system based on the acoustic energy density is investigated. The system is targeted for use in three-dimensional enclosures, such as aircraft cabins and rooms. The acoustic energy density control method senses both the potential and kinetic energy densities, while the most popular control systems of the past have relied on the potential energy density alone. Energy density fields are more uniform than squared pressure fields, and therefore, energy density measurements are less sensitive to sensor location. Experimental results are compared to computer-generated results for control systems based on energy density and squared pressure for a rectangular enclosure measuring 1.5 x 2.4 x 1.9 m. Broadband and narrowband frequency pressure fields in the room are controlled experimentally. Pressure-field and mode-amplitude data are presented for the narrowband experiments, while spectra and pressure-field data are presented for the broadband experiment. It is found that the energy density control system has superior performance to the squared pressure control system since the energy density measurement is more capable of observing the modes of a pressure field. Up to 14.4 and 3.8 dB of cancellation are achieved for the energy density control method for the narrowband and broadband experiments presented, respectively.

Journal Article↗

Error analysis of a practical energy density sensor

The investigation of an active control system based on acoustic energy density has led to the analysis and development of an inexpensive three-axes energy density sensor. The energy density sensor comprises six electret microphones mounted on the surface of a 0.025-m (1 in.) radius sphere. The bias errors for the potential, kinetic, and total energy density as well as the magnitude of intensity of a spherical sensor are compared to a sensor comprising six microphones suspended in space. Analytical, computer-modeled, and experimental data are presented for both sensor configurations in the case of traveling and standing wave fields, for an arbitrary incidence angle. It is shown that the energy density measurement is the most nearly accurate measurement of the four for the conditions presented. Experimentally, it is found that the spherical energy density sensor is within +/- 1.75 dB compared to reference measurements in the 110-400 Hz frequency range in a reverberant enclosure. The diffraction effects from the hard sphere enable the sensor to be made more compact by a factor of 3 compared to the sensor with suspended microphones.

Journal Article↗