PubMed Health⌕ Search

Biomedical subjects

Sabee Molloi

Publications and source records attributed to Sabee Molloi.

At least 19 recordsLinked to original sources

Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier.

This study presents a comparison of dual-energy imaging with an x-ray image intensifier and flat-panel detector for cardiac imaging. It also investigates if the wide dynamic range of the flat-panel detector can improve dual-energy image quality while reducing patient dose. Experimental contrast-to-noise (CNR) measurements were carried out in addition to simulation studies. Patient entrance exposure and system tube loading were also recorded. The studied contrast objects were calcium and iodine. System performance was quantified with a figure-of-merit (FOM) defined as the image CNR(2) over patient entrance exposure. The range of thickness studied was from 10 to 30 cm of Lucite (PMMA). Detector dose was initially set to 140 nGy (16 microR)/frame. The high-energy 120 kVp beam was filtered by an additional 0.8 mm silver filter. Keeping the same filament current, the kVp for the low-energy beam was adjusted as a function of thickness until 140 nGy was achieved. System performance was found to be similar for both systems, with the x-ray image intensifier performing better at lower thicknesses and the flat-panel detector performing better at higher thicknesses. This requirement of fixed detector entrance exposure was then relaxed and the kVp for the low-energy beam was allowed to vary while the mAs of the x-ray tube remained fixed to study changes in dual-energy image quality, patient dose and FOM with the flat-panel detector. It was found that as the kVp for the low-energy beam was reduced, system performance would rise until reaching a maximum while simultaneously lowering patient exposure. Suggested recommendations for optimal dual-energy imaging implementation are also provided.

Bone and Bones↗

Positron autoradiography for intravascular imaging: feasibility evaluation.

Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sudden death. Morphological imaging such as angiography or intravascular ultrasound cannot determine inflammation status of the plaque. A radiotracer such as 18F-FDG is accumulated in vulnerable plaques due to higher metabolic activity of the inflamed cap and could be used to detect a vulnerable plaque. However, positron emission tomography (PET) cannot detect the FDG-labelled plaques because of respiratory and heart motions, small size and low activity of the plaques. Plaques can be detected using a miniature particle (positron) detector inserted into the artery. In this work, a new detector concept is investigated for intravascular imaging of the plaques. The detector consists of a storage phosphor tip bound to the end of an intravascular catheter. It can be inserted into an artery, absorb the 18F-FDG positrons from the plaques, withdrawn from the artery and read out. Length and diameter of the storage phosphor tip can be matched to the length and the diameter of the artery. Monte Carlo simulations and experimental evaluations of coronary plaque imaging with the proposed detector were performed. It was shown that the sensitivity of the storage phosphor detector to the positrons of 18F-FDG is sufficient to detect coronary plaques with 1 mm and 2 mm sizes and 590 Bq and 1180 Bq activities in the arteries with 2 mm and 3 mm diameters, respectively. An experimental study was performed using plastic tubes with 2 mm diameter filled with an FDG solution, which simulates blood. FDG spots simulating plaques were placed over the surface of the tube. A phosphor tip was inserted into the tube and imaged the plaques. Exposure time was 1 min in all simulations and experiments. Experiments showed that detecting the coronary plaques using the proposed technique is possible. The proposed technique has the potential for fast and accurate detection of vulnerable coronary and other intravascular plaques.

Autoradiography↗

Automated technique for angiographic determination of coronary blood flow and lumen volume.

RATIONALE AND OBJECTIVES: Visual interpretation of angiographic images has been shown to be inadequate for assessing the severity of intermediate coronary stenoses. An approach for evaluating both the anatomic and functional impact of a stenosis is needed. An automated technique for determining both coronary blood flow and lumen volume based on a first-pass analysis (FPA) of coronary angiograms and a template matching algorithm was evaluated. MATERIALS AND METHODS: Coronary angiograms of a swine animal model were obtained during power injections of contrast material into the left coronary ostium. Background anatomy was subtracted with an automated phase matching program. A template matching algorithm and first-pass analysis were then used to quantify coronary blood flow and lumen volume. Coronary blood flow and lumen volume measurements were validated with a transit-time ultrasound flow probe and a polymer cast of the coronary arteries, respectively. RESULTS: In 14 independent comparisons, the mean coronary blood flow measured with FPA showed strong correlation with the mean flow measured with the ultrasound flow probe (Q(FPA) = 0.88Q(probe) - 1.99; r = 0.977; standard error of estimate = 3.23 mL/minute). The lumen volumes determined with FPA and cast measurements demonstrated excellent correlation and can be related to each other by V(FPA) = 0.95V(C) - 0.01 (r = 0.997; standard error of estimate = 0.01 mL). CONCLUSIONS: The proposed automated method for accurate determination of coronary blood flow and lumen volume can supplement visual evaluation of coronary anatomy with quantitative physiologic data. This automated technique potentially offers a clinically feasible method of quantifying coronary blood flow and lumen volume in conjunction with routine cardiac catheterization.

Algorithms↗

Optimization of a flat-panel based real time dual-energy system for cardiac imaging.

A simulation study was conducted to evaluate the effects of high-energy beam filtration, dual-gain operation and noise reduction on dual-energy images using a digital flat-panel detector. High-energy beam filtration increases image contrast through greater beam separation and tends to reduce total radiation exposure and dose per image pair. It is also possible to reduce dual-energy image noise by acquiring low and high-energy images at two different detector gains. In addition, dual-energy noise reduction algorithms can further reduce image noise. The cumulative effect of these techniques applied in series was investigated in this study. The contrast from a small thickness of calcium was simulated over a step phantom of tissue equivalent material with a CsI phosphor as the image detector. The dual-energy contrast-to-noise ratio was calculated using values of energy absorption and energy variance. A figure-of-merit (FOM) was calculated from dual-energy contrast-to-noise ratio (CNR) and patient effective dose estimated from values of entrance exposure. Filter atomic numbers in the range of 1-100 were considered with thicknesses ranging from 0-2500 mg/cm2. The simulation examined combinations of the above techniques which maximized the FOM. The application of a filter increased image contrast by as much as 45%. Near maximal increases were seen for filter atomic numbers in the range of 40-60 and 85-100 with masses above 750 mg/cm2. Increasing filter thickness beyond 1000 mg/cm2 increased tube loading without further significant contrast enhancement. No additional FOM improvements were seen with dual gain before or after the application of any noise reduction algorithm. Narrow beam experiments were carried out to verify predictions. The measured FOM increased by more than a factor of 3.5 for a silver filter thickness of 800 microm, equal energy weighting and application of a noise clipping algorithm. The main limitation of dynamic high-energy filtration is increased tube loading. The results of this study can be used to help develop an optimal dual-energy imaging system.

Algorithms↗

Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification.

The feasibility of a real-time dual-energy imaging technique with dynamic filtration using a flat panel detector for quantifying coronary arterial calcium was evaluated. In this technique, the x-ray beam was switched at 15 Hz between 60 kVp and 120 kVp with the 120 kVp beam having an additional 0.8 mm silver filter. The performance of the dynamic filtration technique was compared with a static filtration technique (4 mm Al+0.2 mm Cu for both beams). The ability to quantify calcium mass was evaluated using calcified arterial vessel phantoms with 20-230 mg of hydroxylapatite. The vessel phantoms were imaged over a Lucite phantom and then an anthropomorphic chest phantom. The total thickness of Lucite phantom ranges from 13.5-26.5 cm to simulate patient thickness of 16-32 cm. The calcium mass was measured using a densitometric technique. The effective dose to patient was estimated from the measured entrance exposure. The effects of patient thickness on contrast-to-noise ratio (CNR), effective dose, and the precision of calcium mass quantification (i.e., the frame to frame variability) were studied. The effects of misregistration artifacts were also measured by shifting the vessel phantoms manually between low- and high-energy images. The results show that, with the same detector signal level, the dynamic filtration technique produced 70% higher calcium contrast-to-noise ratio with only 4% increase in patient dose as compared to the static filtration technique. At the same time, x-ray tube loading increased by 30% with dynamic filtration. The minimum detectability of calcium with anatomical background was measured to be 34 mg of hydroxyapatite. The precision in calcium mass measurement, determined from 16 repeated dual-energy images, ranges from 13 mg to 41 mg when the patient thickness increased from 16 to 32 cm. The CNR was found to decrease with the patient thickness linearly at a rate of (-7%/cm). The anatomic background produced measurement root-mean-square (RMS) errors of 13 mg and 18 mg when the vessel phantoms were imaged over a uniform (over the rib) and nonuniform (across the edge of rib) bone background, respectively. Misregistration artifacts due to motions of up to 1.0 mm between the low- and high-energy images introduce RMS error of less than 4.3 mg, which is much smaller than the frame to frame variability and the measurement error due to anatomic background. The effective dose ranged from 1.1 to 6.6 microSv for each dual-energy image, depending on patient thickness. The study shows that real-time dual-energy imaging can potentially be used as a low dose technique for quantifying coronary arterial calcium.

Artifacts↗

Real-time tumor tracking using implanted positron emission markers: concept and simulation study.

The delivery accuracy of radiation therapy for pulmonary and abdominal tumors suffers from tumor motion due to respiration. Respiratory gating should be applied to avoid the use of a large target volume margin that results in a substantial dose to the surrounding normal tissue. Precise respiratory gating requires the exact spatial position of the tumor to be determined in real time during treatment. Usually, fiducial markers are implanted inside or next to the tumor to provide both accurate patient setup and real-time tumor tracking. However, current tumor tracking systems require either substantial x-ray exposure to the patient or large fiducial markers that limit the value of their application for pulmonary tumors. We propose a real-time tumor tracking system using implanted positron emission markers (PeTrack). Each marker will be labeled with low activity positron emitting isotopes, such as 124I, 74As, or 84Rb. These isotopes have half-lives comparable to the duration of radiation therapy (from a few days to a few weeks). The size of the proposed PeTrack marker will be 0.5-0.8 mm, which is approximately one-half the size of markers currently employed in other techniques. By detecting annihilation gammas using position-sensitive detectors, multiple positron emission markers can be tracked in real time. A multimarker localization algorithm was developed using an Expectation-Maximization clustering technique. A Monte Carlo simulation model was developed for the PeTrack system. Patient dose, detector sensitivity, and scatter fraction were evaluated. Depending on the isotope, the lifetime dose from a 3.7 MBq PeTrack marker was determined to be 0.7-5.0 Gy at 10 mm from the marker. At the center of the field of view (FOV), the sensitivity of the PeTrack system was 240-320 counts/s per 1 MBq marker activity within a 30 cm thick patient. The sensitivity was reduced by 45% when the marker was near the edge of the FOV. The scatter fraction ranged from 12% (124I, 74As) to 16% (84Rb). In addition, four markers (labeled with 124I) inside a 30 cm diameter water phantom were simulated to evaluate the feasibility of the multimarker localization algorithm. Localization was considered successful if a marker was localized to within 2 mm from its true location. The success rate of marker localization was found to depend on the number of annihilation events used and the error in the initial estimate of the marker position. By detecting 250 positron annihilation events from 4 markers (average of 62 events per marker), the marker success rates for initial errors of +/-5, +/-10, and +/-15 mm were 99.9%, 99.6%, and 92.4%, respectively. Moreover, the average localization error was 0.55 (+/-0.27) mm, which was independent of initial error. The computing time for localizing four markers was less than 20 ms (Pentium 4, 2.8 GHz processor, 512 MB memory). In conclusion, preliminary results demonstrate that the PeTrack technique can potentially provide real-time tumor tracking with low doses associated with the marker's activity. Furthermore, the small size of PeTrack markers is expected to facilitate implantation and reduce patient risk.

Algorithms↗

Nonuniformity of axial and circumferential remodeling of large coronary veins in response to ligation.

The pressure-induced remodeling of coronary veins is important in coronary venous retroperfusion. Our hypothesis is that the response of the large coronary veins to pressure overload will depend on the degree of myocardial support. Eleven normal Yorkshire swine from either sex, weighing 31-39 kg, were studied. Five pigs underwent ligation of the left anterior descending (LAD) vein, and six served as sham-operated controls. The ligation of the coronary vein caused an increase in pressure intermediate to arterial and venous values. After 2 wk of ligation, the animals were euthanized and the coronary vessels were perfusion-fixed with glutaraldehyde. The LAD vein was sectioned, and detailed morphometric measurements were made along its length from the point of ligation near the base down to the apex of the heart. The structural remodeling of the vein was circumferentially nonuniform because the vein is partially embedded in the myocardium; it was also axially nonuniform because it is tethered to the myocardium to different degrees along its axial length. The wall area was significantly larger in the experimental group, whereas luminal area in the proximal LAD vein was significantly smaller in the same group compared with sham-operated controls. The wall thickness-to-radius ratio was also significantly larger in the experimental group in proportion to the increase in pressure. The major conclusion of this study is that the response of the vein depends on the local wall stress, which is, in part, determined by the surrounding tissue. Furthermore, the geometric remodeling of the coronary vein restores the circumferential stress to the homeostatic value.

Anatomy, Cross-Sectional↗

Photon counting computed tomography: concept and initial results.

A concept of a photon counting cone beam CT is proposed. The system uses a new Multi Slit Multi Slice (MSMS) cone beam acquisition geometry utilizing a linear array photon counting detectors. The MSMS cone beam acquisition is a direct analogy of the scanning multislit acquisition used in projection x-ray imaging. This geometry provides a CT imaging with dose efficient scatter rejection and allows for using available photon counting detectors. The microchannel plate (MCP) detector is proposed as a linear array photon counting detector for MSMS cone beam CT system. Initial testing of the MCP detector for CT application was performed. The field of view of the prototype MCP detector is 60 mm. A delay line position encoding electronics was used. The electronics has a single channel input for evaluation of events from the entire detector field of view. This limits the system count rate at 2 x 10(5) count/s. The spatial resolution of this detector is 80 microm FWHM at 40 kVp and 200 microm FWHM at 90 kVp tube voltages. The detector noise in CT projections is less than 1 count/pixel for the 80 microm pixel size. The CT projections contain quantum-limited and scatter free signal. Images of a contrast phantom and a small animal were acquired at 50 kVp and 80 kVp tube voltages. The CT numbers for different contrast elements were calculated for a given x-ray spectrum and compared with experimental values. The quantum efficiency of the current detector is 56% at 90 kVp, which is suboptimal because of the large channel diameter (25 microm) of these MCPs. The MCPs with smaller channels and higher efficiencies are being tested. The quantum efficiency was measured to be 70% for a new MCP with 5 microm channel diameter. Design parameters of a clinically applicable photon counting MSMS cone beam CT for breast imaging was evaluated. System uses 20 cm field of view MCP detectors based on 5 microm channel MCPs and high count rate ASIC electronics. It was concluded that the MSMS cone beam CT with a photon counting MCP detector is feasible for volume breast imaging.

Breast Neoplasms↗

Effect of area x-ray beam equalization on image quality and dose in digital mammography.

In mammography, thick or dense breast regions persistently suffer from reduced contrast-to-noise ratio (CNR) because of degraded contrast from large scatter intensities and relatively high noise. Area x-ray beam equalization can improve image quality by increasing the x-ray exposure to under-penetrated regions without increasing the exposure to other breast regions. Optimal equalization parameters with respect to image quality and patient dose were determined through computer simulations and validated with experimental observations on a step phantom and an anthropomorphic breast phantom. Three parameters important in equalization digital mammography were considered: attenuator material (Z = 13-92), beam energy (22-34 kVp) and equalization level. A Mo/Mo digital mammography system was used for image acquisition. A prototype 16 x 16 piston driven equalization system was used for preparing patient-specific equalization masks. Simulation studies showed that a molybdenum attenuator and an equalization level of 20 were optimal for improving contrast, CNR and figure of merit (FOM = CNR2/dose). Experimental measurements using these parameters showed significant improvements in contrast, CNR and FOM. Moreover, equalized images of a breast phantom showed improved image quality. These results indicate that area beam equalization can improve image quality in digital mammography.

Artifacts↗

Regional volumetric coronary blood flow measurement by digital angiography: in vivo validation.

RATIONALE AND OBJECTIVES: There are well-known limitations to the use of visual estimation to assess the severity of coronary artery disease and luminal stenosis. This is especially true in the case of an intermediate coronary lesion (30%-70% diameter stenosis), where coronary arteriography is very limited in distinguishing ischemia-producing intermediate coronary lesions from non-ischemia-producing ones. For this reason, a functional measure of stenosis severity is desirable. The goal of this study is to validate a video densitometry technique for quantitative assessment of regional volumetric coronary blood flow. MATERIALS AND METHODS: Coronary arteriography was performed in eight swine (body weight, 25-50 kg) after power injection of contrast material into the left main coronary artery. Phase-matched subtracted images were used to quantify regional coronary blood flow using a video densitometry technique. The in vivo regional flow measurements were validated using a transit time ultrasound flow probe. RESULTS: In 44 measurements, the ultrasound (Q(US)) and video densitometry (Q(VD)) regional flow measurements were related by Q(VD) = 0.98 Q(US) + 0.11 mL/min (r = 0.98). The results of mean regional coronary blood flow measurements for repeated coronary arteriograms of the first (Q(VD1)) and second (Q(VD2)) measured flows were related by Q(VD1) = 1.04 Q(VD2) + 0.05 mL/min (r = 0.97). CONCLUSIONS: A video densitometry technique for quantification of regional coronary blood flow was validated using a swine animal model. The results demonstrated the feasibility and potential utility of the video densitometry technique for accurate measurement of regional coronary blood flow, in vivo. This study provides an angiographic method that can potentially be used to evaluate intermediate coronary lesions during routine coronary arteriography.

Absorptiometry, Photon↗

Area beam equalization: optimization and performance of an automated prototype system for chest radiography.

RATIONALE AND OBJECTIVES: To evaluate the feasibility and performance of an x-ray beam equalization system for chest radiography using anthropomorphic phantoms. MATERIALS AND METHODS: Area beam equalization involves the process of the initial unequalized image acquisition, attenuator thickness calculation, mask generation using a 16 x 16 piston array, and final equalized image acquisition. Chest radiographs of three different anthropomorphic phantoms were acquired with no beam equalization and equalization levels of 4.8, 11.3, and 21. Six radiologists evaluated the images by scoring them from 1-5 using 13 different criteria. The dose was calculated using the known attenuator material thickness and the mAs of the x-ray tube. RESULTS: The visibility of anatomic structures in the under-penetrated regions of the chest radiographs was shown to be significantly (P < .01) improved after beam equalization. An equalization level of 4.8 provided most of the improvements with moderate increases in patient dose and tube loading. Higher levels of beam equalization did not show much improvement in the visibility of anatomic structures in the under-penetrated regions. CONCLUSION: A moderate level of x-ray beam equalization in chest radiography is superior to both conventional radiographs and radiographs with high levels of beam equalization. X-ray beam equalization can significantly improve the visibility of anatomic structures in the under-penetrated regions while maintaining good image quality in the lung region.

Feasibility Studies↗

Scanning-slit photon counting x-ray imaging system using a microchannel plate detector.

An experimental prototype of a novel photon counting x-ray imaging system was evaluated. This system is based on an "edge-on" microchannel plate (MCP) detector and utilizes scanning slit imaging configuration. The detector is capable of photon counting, direct conversion, high spatial resolution, controllable physical charge amplification, quantum limited and scatter free operation. The detector provides a 60 mm wide field of view (FOV) and its count rate is 200 kHz for the entire FOV. The count rate of the current system is limited by the position encoding electronics, which has a single input for all events from the entire detector, and incorporates a single channel ADC with 1 micros conversion time. It is shown that the count rate can potentially be improved to clinically acceptable levels using multichannel application specific integrated circuit (ASIC) electronics and multi-slit image acquisition geometry. For a typical acquisition time used in this study, the image noise was measured to be less than the typically acceptable noise level for medical x-ray imaging. It is anticipated that the noise level will be also low after the implementation of the ASIC electronics. The quantum efficiency of the detector was measured to be 40%-56% for an energy range of 50-90 kVp for MCPs used in this study and can be improved to > 80% using MCPs with the optimized parameters. Images of resolution and anthropomorphic phantoms were acquired at an x-ray tube voltage of 50 kVp. The value of contrast transfer function for the detector was measured to be 0.5 at a spatial frequency of 5 lp/mm. The intrinsic spatial resolution of the system is 28 microm FWHM and was limited by the accuracy of the time-to-digital conversion of the position encoding electronics. Given the advantages of the edge-on MCP detector such as direct conversion and physical charge amplification, it can potentially be applied to mammography and chest radiography.

Equipment Design↗

Treatment planning considerations of reshapeable automatic intensity modulator for intensity modulated radiation therapy.

As compared with multi-leaf collimator based intensity modulated radiation therapy (IMRT) techniques, physical modulators have the major advantage of temporally invariant intensity map delivery which makes it more flexible with monitor unit rate, simpler resolution of interrupted treatment and easier implementation and use with respiratory gating. However, traditional physical modulator techniques require long fabrication time and operator intervention during treatments. It has been previously proposed [Xu et al., Med. Phys. 29, 2222-2229 (2002)] that a reshapeable automatic intensity modulator (RAIM) can automatically produce physical modulators by molding a deformable high x-ray attenuation material using a matrix of computer-controlled pistons. RAIM can potentially eliminate the limitations of traditional physical modulators. The present study addresses the treatment planning considerations of RAIM for IMRT. In this study, a 3D treatment-planning system (PLUNC) was modified to include the capability of providing treatment planning using RAIM. Two clinically representative cases were studied: nasopharyngeal and prostate tumors. First, the RAIM system with two different spatial resolutions at isocenter, 1 x 1 cm2 and 0.5 x 0.5 cm2, were evaluated. The treatment planning results of RAIM were then compared with other IMRT techniques such as smooth modulator with ideal (100%-2%) and limited (100%-13%) intensity modulation ranges, segmental multi-leaf collimator (SMLC) with ten intensity levels, 1 cm leaf width and 0.5 cm step size and serial tomotherapy using the Peacock system. Bringing the spatial resolution of RAIM down to 0.5 x 0.5 cm2 did not show improvement due to the effect of penumbra. The RAIM system with 1 x 1 cm2 proved slightly inferior as compared to the ideal smooth physical modulator but better than the SMLC technique and the smooth modulator with limited modulation range. When compared to serial tomotherapy, RAIM is only inferior in brain stem sparing for the nasopharynx case. Furthermore, the RAIM system with 1 x 1 cm2 resolution required significantly lower monitor units as compared to the other IMRT techniques for the two cases studied.

Algorithms↗

Assessment of vasoreactivity using videodensitometry coronary angiography.

BACKGROUND: Previous studies demonstrated that the dysfunction of vasomotor tone (VT) is closely linked to the development of atherosclerosis and it is considered important in the very early stages of atherogenesis. Currently, the evaluation of VT relies on lumen changes in response to vasoactive stimuli using quantitative coronary angiography (QCA) based on geometric edge detection (ED). However, using ED for measuring lumen diameters is inherently associated with large uncertainties. Videodensitometry (VD) methods have important advantages over ED for QCA. The objective of this study was to investigate the reliability of VD and ED techniques in determining the effect of nitroglycerin (NTG) on cross-sectional area (CSA) and volume changes in a swine animal model for evaluating coronary vasoreactivity. METHODS AND RESULTS: Coronary angiography was performed on four anesthetized swine. CSA and volume were measured in the left anterior descending (LAD) coronary artery using VD before and after intracoronary injection of 0.3 mg of NTG. CSA was also calculated using standard QCA based on ED. The average CSA changes in the proximal, middle and distal branches measured using VD were 23.83% (+/-10.76%), 30.78% (+/-18.39%), and 27.34% (+/-36.53%), respectively. Similarly, the average CSA changes in the proximal, middle, and distal branches measured using ED were 15.02% (+/-36.38%), 22.02% (+/-26.12), and 38.00% (+/-48.31%), respectively. The average lumen volume change measured using VD was 29.79% (+/-14.79%). In order to evaluate the relative reliability of the techniques. the significance of deviation (SOD) was calculated, which is the ratio of the change after NTG and the measurement error. The average SOD for CSA for all the branches based on VD and ED were 1.86 and 0.69, respectively. The SOD for volume measurement was 2.78. CONCLUSIONS: Lumen changes measured by VD showed substantial improvement in reliability when compared to the ED. Moreover, VD can be used to measure substantially smaller changes in lumen dimension in response to vasoactive stimuli than the standard QCA based on ED. Finally, VD allows the measurement of arterial volume, which is not possible with ED.

Absorptiometry, Photon↗

Effect of vessel orientation on videodensitometry quantitative coronary arteriography.

Cross-sectional area measurement using videodensitometry coronary arteriography is a function of the out-of-plane angle of the vessel segment with respect to the face of the image intensifier. Therefore, absolute cross-sectional area measurement using videodensitometry requires correction for the out-of-plane angle. In this study, a simple technique to measure the out-of-plane angle of a vessel segment using images from two different projections is presented. The technique was tested using vessel phantoms imaged at different out-of-plane angles. A vessel segment with an out-of-plane angle of less than 20 degrees introduces less than 5% error in the cross-sectional area measurements. However, an out-of-plane angle of 60 degrees can introduce more than 90% error. The results of the measurements show that correction for the out-of-plane angle reduces the error in cross-sectional area measurement to less that 5%. The correction for the out-of-plane angle makes it possible to measure the absolute cross-sectional area using videodensitometery, which can be used to assess a diseased vessel segment with any complex geometry.

Absorptiometry, Photon↗

Patient-specific region-of-interest fluoroscopy device for X-ray dose reduction.

A region-of-interest (ROI) fluoroscopy device that provides an automatically generated ROI filter with an arbitrary shape, as well as digitally compensated images, was built and evaluated. ROI filters were generated by using a deformable attenuation material. Images were compensated by using a compensation ratio and a running average interpolation method. Image compensation parameters were predicted on the basis of the x-ray tube potential used. The image quality with and without an ROI filter was evaluated. This ROI fluoroscopic technique was shown to substantially reduce patient and operator radiation exposure without degrading image quality within the ROI.

Filtration↗

Effect of passive myocardium on the compliance of porcine coronary arteries.

The objective of this study was to determine the effect of passive myocardium on the coronary arteries under distension and compression. To simulate distension and compression, we placed a diastolic-arrested heart in a Lucite box, where both the intravascular pressure and external (box) pressure were varied independently and expressed as a pressure difference (DeltaP = intravascular pressure - box pressure). The DeltaP-cross-sectional area relationship of the first several generations of porcine coronary arteries and the DeltaP-volume relationship of the coronary arterial tree (vessels >0.5 mm in diameter) were determined using a video densitometric technique in the range of +150 to -150 mmHg. The vasodilated left anterior descending (LAD) coronary artery of six KCl-arrested hearts were perfused with iodine and 3% Cab-O-Sil. The intravascular pressure was varied in a triangular pattern, whereas the absolute cross-sectional area of each vessel and the total arterial volume were calculated using video densitometry under different box pressures (0, 50, 100, and 150 mmHg). In the range of positive DeltaP, we found that the compliance of the proximal LAD artery in situ (4.85 +/- 3.8 x 10-3 mm2/mmHg) is smaller than that of the same artery in vitro (16.5 +/- 6 x 10-3 mm2/mmHg; P = 0.009). Hence, the myocardium restricts the compliance of the epicardial artery under distension. In the negative DeltaP range, the LAD artery does not collapse, whereas the same vessel readily collapses when tested in vitro. Hence, we conclude that myocardial tethering prevents collapse of large blood vessel under compression.

Angiography, Digital Subtraction↗