PubMed Health⌕ Search

Biomedical subjects

Sabine Weckbach

Publications and source records attributed to Sabine Weckbach.

3 recordsLinked to original sources

Material differentiation by dual energy CT: initial experience.

The aim of this study was to assess the feasibility of a differentiation of iodine from other materials and of different body tissues using dual energy CT. Ten patients were scanned on a SOMATOM Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) system in dual energy mode at tube voltages of 140 and 80 kVp and a ratio of 1:3 between tube currents. Weighted CT Dose Index ranged between 7 and 8 mGy, remaining markedly below reference dose values for the respective body regions. Image post-processing with three-material decomposition was applied to differentiate iodine or collagen from other tissue. The results showed that a differentiation and depiction of contrast material distribution is possible in the brain, the lung, the liver and the kidneys with or without the underlying tissue of the organ. In angiographies, bone structures can be removed from the dataset to ease the evaluation of the vessels. The differentiation of collagen makes it possible to depict tendons and ligaments. Dual energy CT offers a more specific tissue characterization in CT and can improve the assessment of vascular disease. Further studies are required to draw conclusions on the diagnostic value of the individual applications.

Algorithms↗

MRA of abdominal vessels: technical advances.

Magnetic resonance angiography (MRA) in general and MRA of the abdominal vessels in particular have undergone substantial improvements in the past 5 years triggered by the introduction and application of parallel imaging (PI), new sequence techniques such as centric k-space trajectories and undersampling, dedicated contrast agents and clinical high-field scanners. All of these techniques have the potential to improve image quality and resolution or decrease the image acquisition time. However, each of them has its own specific advantages and drawbacks. This review describes the main technical innovations and focuses on the impact these developments may have on abdominal MRA. Special consideration is given to the interaction of these various technical advances. The clinical value of advanced MRA techniques is discussed and illustrated by characteristic cases.

Abdomen↗

Quantitative assessment of patellar cartilage volume and thickness at 3.0 tesla comparing a 3D-fast low angle shot versus a 3D-true fast imaging with steady-state precession sequence for reproducibility.

OBJECTIVES: We sought to compare patellar cartilage volume and thickness measurement between 3D-FLASH and 3D-True fast imaging with steady-state precession (FISP) image data at 3.0 T. MATERIALS AND METHODS: One knee each of 6 healthy adults was examined by axial magnetic resonance imaging (MRI) performed with a 3D-fast flow angle shot (FLASH) water-excitation sequence and a 3D-TrueFISP water-excitation sequence (spatial resolution 0.31 x 0.31 x 1.5 mm3). Patellar cartilage volume and mean/maximum thickness were calculated. Intraindividual/average reproducibility and interindividual variability were determined from 3 consecutive data sets acquired for each volunteer and sequence. RESULTS: Patellar cartilage volume and thickness as well as reproducibility was slightly but not significantly lower for the 3D-TrueFISP data than for the 3D-FLASH data (volume: 3.4-6.3 mL (3D-FLASH)/3.1-6.0 mL (3D-TrueFISP), average reproducibility 1.8% (3D-FLASH)/4.4% (3D-TrueFISP); mean thickness: 2.1-2.8 mm (3D-FLASH)/1.9-2.6 mm (3D-TrueFISP), average reproducibility 2.8% (3D-FLASH)/3.8% (3D-TrueFISP); maximum thickness: 4.7-6.6 mm (3D-FLASH)/4.5-6.2 mm (3D-TrueFISP), average reproducibility 2.6% (3D-FLASH)/4.1% (3D-TrueFISP)). Interindividual variability was comparable for both sequence techniques. CONCLUSION: At 3.0 T, the 3D-FLASH sequence showed tendency to be slightly superior to the 3D-TrueFISP sequence considering robust and valid assessment of quantitative cartilage parameters in young healthy adults, although there was found no significant statistical difference between both imaging techniques. However, in patients suffering from osteoarthritis (OA), the 3D-TrueFISP sequence might prove advantageous for monitoring of disease progression and evaluation of therapy success, particularly because the substantially higher signal to noise ratio/contrast to noise ratio values might allow for higher spatial resolution and hence for improvement of the accuracy of segmentation process especially at the articular surface.

Adult↗