Choice of rotation speed (rpm) for bio-relevant drug dissolution testing using a crescent-shaped spindle.

Recently a new crescent-shaped spindle has been proposed to address the issues related to poor hydrodynamics of the USP paddle apparatus and its associated artifacts of high variability and lack of bio-relevant results. For improved comparison of drug dissolution characterization, it is highly desirable to conduct testing using common experimental conditions such as spindle rotation speed. A study was conducted in which different products were tested using the crescent-shaped spindle to propose a common rpm speed for improved comparative drug dissolution testing. Conventional- (200 mg) and extended-release (200 and 400 mg) carbamazepine tablets of multiple brands and amoxicillin capsules (250 and 500 mg) were analysed using the crescent- shaped spindle at 25, 50 and/or 75 rpm. Drug release was evaluated for 1.5h for amoxicillin and for 3.0 and 24h for conventional- and extended-release carbamazepine tablets products respectively. The dissolution media used were 0.05 M phosphate buffer for amoxicillin capsules and water containing 0.5% sodium lauryl sulphate for carbamazepine tablet products. All products showed characteristic drug release profiles, reflecting the fast and slow drug release natures of the products tested with complete drug release within expected time durations. Based on an expected maximum drug release criterion of 85% in a reasonable time, at a relatively slow drug release rate and within a dosing interval, a spindle speed of 25 rpm was found to be the most appropriate. Thus, it is concluded that drug products can be analysed using a single spindle type (crescent) with a single rpm (25) which would, not only result in simpler dissolution procedures, but also provide enhanced efficiencies from economical and regulatory aspects.

Amoxicillin↗

Improved drug dissolution and product characterization using a crescent-shaped spindle.

Drug release characteristics of two amoxicillin capsule products, 250 and 500 mg strength each, have been described using USP Paddle and crescent-shaped spindles. Using the same spindles, dissolution experiments were conducted with USP disintegrating (prednisone) and non-disintegrating (salicylic acid) calibrator tablets. Dissolution tests were conducted at 50 and 25 rev min(-1) using USP Paddle and crescent-shaped spindles, respectively. In all cases, even with the higher 50 rev min(-1), lower percent drug release results were observed with the Paddle spindle than with the crescent-shaped spindle, which was operated at 25 rev min(-1). The observed lower dissolution for amoxicillin capsule products (< 36 vs > 87% at 30 min) and USP prednisone calibrator tablets (45.5 vs 99.8% at 30 min) with Paddle spindles appeared to occur because of the accumulation of the disintegrated material (cone formation) at the bottom, thus restricting product-medium interaction. Crescent-shaped spindles did not allow any accumulation of the product and provided improved interaction by mixing and stirring, and thus appeared to provide true drug dissolution characteristics of the products. On the other hand, in the case of non-disintegrating USP salicylic acid tablets (18.5 vs 24.4% at 30 min), lower results with Paddle spindles appeared to be because of stagnation of the tablets, which provided poor product-medium interaction for the surface touching the vessel surface. In this case, the crescent-shaped spindles moved the tablets at the base of the vessel, providing improved and efficient product-medium interaction, thus appearing to reflect truer dissolution characteristics of the tablets. The results highlight the possible artifacts of the USP Paddle spindle, which could lead to inaccurate characterization of drug release properties of test products. As reported previously, the artifacts of high variability in results and lack of relevance to product properties appeared to be related to poor mixing and variable hydrodynamics within a dissolution vessel. Results from this study provide further evidence that these artifacts might be addressed adequately using the crescent-shaped spindle, thus resulting in improved drug release as well as better product characterization.

Amoxicillin↗

Applications of a new device (spindle) for improved characterization of drug release (dissolution) of pharmaceutical products.

A crescent spindle (patent pending) is described which may be used in place of the USP paddle component in USP dissolution apparatus 2. The new spindle is curve shaped, corresponding to the bottom of a dissolution vessel, with attached bristles to fill in the gap between the spindle and the surface of the vessel. The geometry of the new spindle provides more efficient mixing than the USP paddle and prevents accumulation of disintegrated material (no cone formation). Using the new spindle, in comparison with the USP paddle, dissolution characteristics of three drug products: 250 mg amoxicillin capsules, 15.6 g acetylsalicylic acid (ASA) boluses and 200 mg carbamzepine tablets were evaluated. The experimental conditions for dissolution testing with the two stirring devices included; 900 ml of 0.05 M phosphate buffer, pH 6.8 with 50 rpm, 900 ml of 0.05 M acetate buffer, pH 4.5-ethanol (7:3) with 50 rpm, and water containing 1% sodium lauryl sulphate with 75 rpm for amoxicillin capsules, ASA boluses and carbamazepine tablets, respectively. Uncharacteristic of the test products, which are fast release, the USP paddle provides significantly slower drug release. For example, 90 min for <80% drug release vs. 10 min for >90% for amoxicillin capsules and 6 h for 80% vs. 30 min for >90% for ASA boluses with USP paddle vs. the new spindle. In case of the carbamazepine tablets, three products which are bioequivalent and prescribed interchangeably, the USP paddle method shows significantly different dissolution characteristics. However, with the new device, all these products show similar drug release characteristics, a better reflection of product release characteristics and in vivo drug release behaviour. Compared with the USP paddle, the suggested device (spindle) provides improved stirring and mixing which appears to provide more appropriate (biorelevant) characterization of pharmaceutical products.