PubMed Health⌕ Search

Biomedical subjects

Salem Omar

Publications and source records attributed to Salem Omar.

12 recordsLinked to original sources

New approach to diagnosing ampullary tumors by magnifying endoscopy combined with a narrow-band imaging system.

BACKGROUND: A newly developed narrow-band imaging (NBI) system, which uses modified optical filters, can yield clear images of microvessels and surface structure in gastric and colonic diseases. In the present study, we investigated the ability of magnifying endoscopy with NBI (MENBI) to diagnose and differentiate between benign and malignant ampullary tumors. METHODS: Fourteen patients, whose ampullas were noted to be significantly enlarged or protruding with conventional endoscopy, were enrolled in the study. Specimens, which were obtained by forceps biopsy, endoscopic papillectomy, and/or surgery, were retrieved for histopathological examination. The correlation between MENBI images and histopathological findings was investigated. MENBI findings were classified as I, oval-shaped villi; II, pinecone/leaf-shaped villi; or III, irregular/nonstructured. In addition, tortuous, dilated, and network-like vessels noted on the ampullary lesions with MENBI were defined as abnormal vessels. RESULTS: In 6 of 14 patients, the ampullary changes were proven to be inflammatory in forceps biopsy specimens, without any evidence of malignancy after more than 1 year of follow-up. In five patients, ampullary lesions were treated by endoscopic papillectomy, and in three, by pancreatoduodenectomy. All adenomas and adenocarcinomas had type II and/or type III surface structures, and patients whose ampulla had a type I surface structure had only inflammatory or hyperplastic changes. In addition, abnormal vessels were seen only in adenocarcinomas and never in adenomas. CONCLUSIONS: MENBI has the ability and potential to predict histological characteristics of ampullary lesions.

Adenocarcinoma↗

Use of modified multiband ligator facilitates circumferential EMR in Barrett's esophagus (with video).

BACKGROUND: Various techniques are available for EMR in the upper- and lower-GI tract. For early cancers of the esophagus, the "suck and cut" technique, which uses a transparent cap or variceal band ligator, is the most commonly practiced method. To facilitate multiple or circumferential EMR, a modified multiband variceal ligator (MBL) is introduced, which allows sequential banding and snare resection without the need to withdraw the endoscope. OBJECTIVE: To study the feasibility of modified MBL device in facilitating circumferential EMR of Barrett's esophagus (BE) that contains high-grade intraepithelial neoplasia (HGIN) and/or intramucosal cancer (IMC). DESIGN: To enable band delivery with a snare inserted in the therapeutic endoscope, the threading channel of the cranking device is enlarged from 2 to 3.2 mm. The 6-shooter MBL was used. PATIENTS: Ten consecutive patients (all men; median age, 62 years; range 43-82 years) with BE were treated. IMC and HGIN were found in 8 and 2 patients, respectively. INTERVENTIONS: EMR was performed with pure coagulating current when using a 1.5 x 2.5-cm mini hexagonal polypectomy snare. No submucosal saline solution injection was performed before resection. RESULTS: In 5 of 10 patients with circumferential BE of 2 to 9 cm in length (median, 4 cm), complete circumferential EMR was performed in 1 session by using 3 to 18 bands (median, 6). Four patients with 3- to 10-cm (median, 4 cm) long segment BE required 2 to 5 sessions (median, 3) with a total of 5 to 42 bands (median, 12). Another patient with multifocal HGIN and/or IMC in 24 of a total of 49 specimens was finally recommended for surgery because of technical difficulties caused by mural thickening after 4 sessions. No serious procedure-related complications were observed, except for 2 minor bleedings, which were controlled endoscopically. Seven patients developed strictures after circumferential EMR. All patients except 1 were successfully managed by weekly bougienage after a median of 5 sessions (range 3-11). Deep-wall tears developed in 1 patient during the fourth bougienage session, for which limited distal esophageal resection was performed with an uneventful outcome. CONCLUSIONS: The novel technique of MBL-EMR described here facilitated and simplified circumferential removal of BE that contained HGIN and/or IMC. However, the method is associated with a very high stricture rate if circumferential EMR is performed in a single session. Complete removal of BE should be achieved by repeated partial EMR. Long-term follow-up is needed to observe for late recurrence and to determine the clinical impact of this method.

Adult↗

One-step, simultaneous double-wire technique facilitates pancreatic pseudocyst and abscess drainage (with videos).

BACKGROUND: EUS-guided pancreatic pseudocyst and abscess drainage ideally requires the insertion of both a transmural stent and nasocystic catheter to ensure continuous irrigation and effective drainage. Sequential stent and nasocystic catheter insertion may be time consuming because of the difficulty in recannulating the pseudocyst after the initial stent placement. OBJECTIVE: Our purpose was to describe a novel one-step simultaneous double-wire technique that facilitates effective pancreatic pseudocyst and abscess drainage. DESIGN: To solve the problem of recannulating the pseudocyst cavity after the initial transmural stent placement, we developed a prototype 3-layer puncture kit that allows the simultaneous insertion of 2 guidewires at the initial puncture in one step. This puncture kit consists of a 22-gauge needle used for FNA, a 6F inner polytetrafluoroethylene (Teflon) catheter, and an outer 8.5F Teflon catheter. SETTING: Tertiary referral center. PATIENTS: Eight consecutive patients were treated. INTERVENTIONS: With use of a therapeutic linear echoendoscope and the assembled kit with the needle protruding out distally, the pseudocyst cavity was punctured by using electrocautery. The needle and the inner catheter were then withdrawn, leaving the outer catheter within the cavity. The size of this outer catheter permitted the simultaneous insertion of two 0.035-inch guidewires. Sequential insertion of a transmural stent and nasocystic catheter was then performed without a need for recannulation of the pseudocyst or abscess cavity. MAIN OUTCOME MEASUREMENTS: Successful endoscopic drainage. RESULTS: All patients were successfully treated without complications. Mean procedural time was 32.5 minutes (range 25-45 minutes). CONCLUSIONS: With this novel technique, establishing an irrigation system for the treatment of pancreatic pseudocysts and abscesses becomes easier, faster, and safer.

Abscess↗

Endoscopic resection of benign tumors of the duodenal papilla without and with intraductal growth.

BACKGROUND: Endoscopic papillectomy of benign papillary tumor is still not widely practiced. Intraductal growth has been considered a contraindication for endoscopic therapy. This prospective study evaluates endoscopic papillectomy for treatment of benign papillary tumors without and with intraductal growth. METHODS: Monofilament snare and monopolar electrocoagulation were used for papillectomy. A 7F stent was placed in the pancreatic duct. Patients with distal intraductal growth underwent sphincterotomy and endoscopic resection after exclusion of more proximal growth. RESULTS: Between February 1985 and April 2004, 106 patients (109 lesions), 68 women, 38 men, median age 68 years (range 29-88 years) were included. Median tumor size was 2 cm (range 0.5-6 cm) with one session (range 1-8) required for removal. Nine patients had invasive carcinoma (8%). Surgery for incomplete removal or recurrence was performed in 12% of 75 patients without and 37% of 31 patients with intraductal growth (p < 0.01), respectively. Fifteen patients had recurrence (15%); but, only 4 required surgery. Endoscopic resection was curative (median follow-up, 43 months) in 83% without and 46% with intraductal growth (p < 0.001). CONCLUSIONS: Endoscopic papillectomy is safe and effective, and may be feasible in cases of intraductal growth. Surveillance and, if required, re-treatment are mandatory because of the risk of recurrence.

Adult↗

Aggressive endoscopic therapy for pancreatic necrosis and pancreatic abscess: a new safe and effective treatment algorithm (videos).

BACKGROUND: Pancreatic necrosis and pancreatic abscess are severe complications of acute pancreatitis. Surgery is associated with significant morbidity and mortality in these critically ill patients. Endoscopic therapy has the potential to offer a safer and more effective alternative treatment modality. However, its role needs to be further investigated. METHODS: This is a retrospective study of the outcome of consecutive patients with pancreatic necrosis and pancreatic abscess, all unfit to undergo surgery, who underwent a new aggressive endoscopic approach. The treatment includes (1) synchronous EUS-guided multiple transmural and/or transpapillary drainage procedures followed by balloon dilation of the cystogastrostoma or cystoduodenostoma, (2) daily endoscopic necrosectomy and saline solution lavage, and (3) sealing of pancreatic fistula by N-butyl-2-cyanoacrylate. RESULTS: Pancreatic necrosis and pancreatic abscesses were successfully drained in 13 patients, thus avoiding emergency surgery as an initial treatment. Surgery was completely avoided in 9 patients over a median follow-up of 8.3 months (range 3-81 months). Surgery was combined with endoscopic therapy in one patient because of abscess extension into the right paracolic gutter, which was not manageable by endoscopic drainage. Because of the "disconnected-duct syndrome," two patients later developed recurrent pseudocysts and underwent elective surgery. Complications included minor bleeding after balloon dilation and necrosectomy in 4 cases, which were self limiting or controlled endoscopically. CONCLUSIONS: This aggressive endoscopic approach shows promising results. It expands the potential for endoscopic treatment in patients with pancreatic necrosis and/or pancreatic abscess.

Abscess↗

Endoscopic sealing of pancreatic fistula by using N-butyl-2-cyanoacrylate.

BACKGROUND: The treatment of pancreatic fistula can be difficult. A novel endoscopic approach to sealing pancreatic fistulas by using N-butyl-2-cyanoacrylate is described. METHODS: Twelve patients with pancreatic fistulas underwent endoscopic injection of N-butyl-2-cyanoacrylate into the fistulous tract, in addition to endoscopic drainage. RESULTS: Fistulas were closed successfully in 8 of 12 patients. A single treatment session was successful in 7 patients; a second session was required in one patient. In two patients, closure was temporary, and, in one patient, the treatment failed. One patient died 24 hours after treatment. He developed a pulmonary thromboembolism from a left popliteal vein thrombosis and died from complications of surgical thromboembolectomy. At autopsy, a pulmonary embolus was found, but there was no evidence of N-butyl-2-cyanoacrylate in the lungs. No procedure-related complication occurred over a median follow-up of 20.7 months (range 9-51 months). CONCLUSIONS: In this preliminary study, occlusion of pancreatic fistulas by using N-butyl-2-cyanoacrylate glue was safe and effective, and obviated the need for surgery in a substantial proportion of patients. Further studies of the use of N-butyl-2-cyanoacrylate for closure of pancreatic fistula are warranted.

Adult↗

EUS-guided FNA of the left adrenal gland in patients with thoracic or GI malignancies.

BACKGROUND: The diagnostic yield and safety of trans-gastric EUS-guided FNA of the left adrenal gland are not well defined. METHODS: All patients with an enlarged left adrenal gland on abdominal imaging and known or suspected malignancy referred to two EUS centers over a 3-year period were included in this study. EUS-guided FNA was performed on an outpatient basis by one of 4 experienced endosonographers. RESULTS: Thirty-one consecutive patients (21 men, 10 women; mean age 64.8 years) were evaluated. Tissue adequate for interpretation was obtained in all patients; no attempt to obtain tissue was unsuccessful. The median number of needle passes was 4.5 (range 1-8). No immediate complications were encountered. EUS-guided FNA confirmed malignant left adrenal involvement in 42% (13/31) of the patients. Patients with malignant left adrenal masses were more likely to have known cancer at another site (OR 12.0: 95% CI[1.6, 87.9]). Patients with benign masses were more likely to have preservation of the normal sonographic appearance of the adrenal gland ("seagull" configuration) compared with those with malignant masses (OR 9.8: 95% CI[1.9, 51.0]). The accuracy of EUS imaging based on size (> or =3 cm) alone was 81%: 95% CI[63, 93]). Of the patients with malignant adrenal masses, 85% (11/13) died or their clinical condition deteriorated during follow-up, while 15% (2/13) were being treated and were stable clinically. CONCLUSIONS: EUS-guided FNA of the left adrenal gland is a minimally invasive, safe, and highly accurate method that confirms or excludes malignant adrenal involvement in patients with thoracic or GI malignancies.

Adrenal Gland Neoplasms↗