Salvador Alegret

Publications and source records attributed to Salvador Alegret.

10 recordsLinked to original sources

Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples.

Urea biosensors based on urease covalently immobilized on to ammonium and hydrogen ion-selective electrodes were included in arrays together with ammonium, potassium, sodium, hydrogen and generic response to alkaline sensors. Response models based on artificial neural network (ANN) and partial least squares (PLS1) were built, tested and compared for the simultaneous determination of urea, ammonium, potassium and sodium. The results show that it is possible to obtain good ANN and PLS calibration models for simultaneous determination of these four species, but with better prediction capability when the ANN are used. The developed bioelectronic tongue was applied to multidetermination in urine samples. The ANN model showed again better agreement with reference methods, allowing a simple direct determination of urea in the real samples without the necessity of eliminating the alkaline interferences, or compensating endogenous ammonium.

Biosensing Techniques↗

Graphite epoxy composite electrodes modified with bacterial cells.

The modification of a graphite-epoxy composite electrode (GECE) with bacterial cells along with an analytical application are presented. Pseudomonas putida DSM 50026 was used as a biological component and the measurement was based on the respiratory activity of the cells. The optimization of working conditions of resulting biosensor (including pH and temperature) was conducted and the limit of detection was calculated as 7 microM phenol based on the signal to noise ratio. Then the system was applied for xenobiotic detection. Resulting sample signals were found to be very similar with the standard solutions having the same concentration while the recoveries of the spiked samples were close to 100%.

Biosensing Techniques↗

Microchip electrophoresis with wall-jet electrochemical detector: influence of detection potential upon resolution of solutes.

This report studies the electrochemical response of wall-jet detector for microchip electrophoresis (microCE). It shows that in wall-jet configuration, the electrochemical detector operates in coulometric mode and that there is an influence of detection potential upon peak width and therefore upon the resolution of solutes. Upon raising the detection potential from +0.3 to +0.9 V, the resolution between model analytes, dopamine and catechol, increases from 0.63 to 2.90. The reasons for this behavior originate in wall-jet detector design and in its typically significant higher detector volume than the volume of injected sample. The conversion efficiency of the wall-jet electrochemical detection cell was found to be 97.4% for dopamine and 98.0% for catechol. The paper brings deeper understanding of operations of wall-jet electrochemical detectors for microchip devices, and it explains previously reported significantly sharper peaks when electrocatalytic electrodes (i.e., palladium and carbon nanotube) were used in microCE-electrochemistry wall-jet detector.

Catechols↗

Magnetically trigged direct electrochemical detection of DNA hybridization using Au67 quantum dot as electrical tracer.

A novel gold nanoparticle-based protocol for detection of DNA hybridization based on a magnetically trigged direct electrochemical detection of gold quantum dot tracers is described. It relies on binding target DNA (here called DNA1) with Au(67) quantum dot in a ratio 1:1, followed by a genomagnetic hybridization assay between Au(67)-DNA1 and complementary probe DNA (here called DNA2) marked paramagnetic beads. Differential pulse voltammetry is used for a direct voltammetric detection of resulting Au(67) quantum dot-DNA1/DNA2-paramagnetic bead conjugate on magnetic graphite-epoxy composite electrode. The characterization, optimization, and advantages of the direct electrochemical detection assay for target DNA are demonstrated. The two main highlights of presented assay are (1) the direct voltammetric detection of metal quantum dots obviates their chemical dissolution and (2) the Au(67) quantum dot-DNA1/DNA2-paramagnetic bead conjugate does not create the interconnected three-dimensional network of Au-DNA duplex-paramagnetic beads as previously developed nanoparticle DNA assays, pushing down the achievable detection limits.

DNA↗

Toward an ICPMS-linked DNA assay based on gold nanoparticles immunoconnected through peptide sequences.

Gold nanoparticles modified with anti-mouse IgG have been used to trace oligonucleotides carrying a c-myc peptide. Two strategies, a dot-blot format as well as inductively coupled plasma mass spectrometry (ICPMS) have been used to detect the nanoparticle tracer. For both cases, oligonucleotide-peptide conjugates were first applied to a nitrocellulose membrane using a manifold attached to a suction device. After immobilization of the oligonucleotide by UV radiation, the samples were incubated with an anti-c-myc monoclonal antibody. In the case of the dot-blot format strategy, it was followed by incubation with a secondary antibody conjugated to horseradish peroxidase and development with luminol as chemiluminescent substrate. In the case of ICPMS strategy, it was followed by incubation with the secondary antibody (anti-mouse IgG) conjugated to gold nanoparticles and their ICPMS detection after dissolving. The nonspecific adsorptions were found to be around zero. The limit of detection for peptide-modified DNA was 0.2 pmol. The method may have significant potential as an important ICPMS-based nonradioactive DNA detection method for the simultaneous determination of various sequences by labeling different kinds of inorganic nanoparticles.

DNA↗

Simultaneous determination of phenolic compounds by means of an automated voltammetric "electronic tongue".

This contribution describes the simultaneous determination of three phenolic compounds, o-cresol, p-chlorophenol and 4-chloro-3-methylphenol, using direct oxidation and amperometric detection coupled by signal deconvolution, accomplished via chemometric methods. Direct oxidation of phenolic compounds is performed at the surface of an epoxy-graphite transducer, by linear scan voltammetry. Due to strong signal overlapping, artificial neural networks (ANNs) were used during data treatment, in a combination of chemometrics and electrochemical sensors known as an "electronic tongue". To calibrate this system properly, a total of 80 mixed samples were prepared automatically by employing a sequential injection analysis (SIA) system designed to automatically generate the information needed to train the network. The phenolic compound concentration varied from 1 to 70 microM for o-cresol, from 0.5 microM to 140 microM for p-chlorophenol and from 1 microM to 100 microM for 4-chloro-3-methylphenol. A good prediction capability was obtained, with correlation coefficients >0.964 when the obtained values were compared with those expected for a set of 24 external test samples not used for training. The results presented here indicate that this technique is a simple and robust analytical method of environmental interest.

Journal Article↗

Glucose biosensor based on carbon nanotube epoxy composites.

A novel glucose biosensor based on a rigid and renewable carbon nanotube (CNT) based biocomposite is reported. The biosensor was based on the immobilization of glucose oxidase (GOx) within the CNT epoxy-composite matrix prepared by dispersion of multi-wall CNT inside the epoxy resin. The use of CNT, as the conductive part of the composite, ensures better incorporation of enzyme into the epoxy matrix and faster electron transfer rates between the enzyme and the transducer. Experimental results show that the CNT epoxy composite biosensor (GOx-CNTEC) offers an excellent sensitivity, reliable calibration profile, and stable electrochemical properties together with significantly lower detection potential (+0.55 V) than GOx-graphite epoxy composites (+0.90 V; difference deltaE = 0.35 V). The results obtained favorably compare to those of a glucose biosensor based on a graphite epoxy composite (GOx-GEC).

Biosensing Techniques↗

Carbon composite microelectrodes: charge percolation and electroanalytical performance.

Microelectrodes based on two different epoxy-graphite composites (Araldite-M/HY5162 and Araldite-PY302-2/HY943) that are compatible with organic solvents have been developed and characterized. The variation in the bulk conductivity with graphite particle loading is described by percolation theory and indicates that the particles interact strongly with one another. The percolation threshold is 52% v/v loading of graphite, and this composite exhibits a bulk conductivity of 15 S m(-1). Microdisk electrodes of 25-microm diameter were produced by first etching a microcavity at the tip of a platinum microelectrode, which was then packed with a composite containing 60% v/v graphite so as to optimize both electrical conductivity and the electrode stability in acetonitrile and methanol solutions. Solution phase voltammetry of ferrocene is nearly ideal, and the responses are dominated by radial diffusion (slow scan rates) and semi-infinite linear diffusion (fast scan rates). The microelectrodes display high signal-to-noise ratios, good sensitivity, and low detection limits. The response times given by the product of the resistance, R, and capacitance, C, are 7.5 x 10(-4) and 1.4 x 10(-1) s for the Araldite M and PY302-2 composites, respectively. Although these response times are significantly slower than those associated with microelectrodes based on carbon fibers or metal wires, they are sufficient for time-resolved electroanalytical applications. The long response times arise from the large composite resistances, 3.1 x 10(11) and 8.3 x 10(11) Omega cm(-2) for Araldite M and PY302-2, respectively. Voltammetry of ferrocene in the absence of deliberately added supporting electrolyte is also reported. Significantly, indistinguishable slopes and intercepts for a calibration curve of peak current vs ferrocene concentration where 2 < [ferrocene] < 50 microM are obtained in the presence and absence of supporting electrolyte.

Journal Article↗

Graphite-epoxy composites as a new transducing material for electrochemical genosensing.

The use of a rigid carbon-polymer composite material as an electrochemical transducer in hybridisation genosensors is reported. Graphite-epoxy composites (GEC) have an uneven surface where DNA can be adsorbed using a simple dry-adsorption procedure. Single-stranded-DNA binds strongly to GEC in a way that prevents the strands from self-associating, while permitting hybridisation with complementary DNA. Hybridisation has been detected through biotin-streptavidin interaction using a streptavidin conjugated to horseradish peroxidase. Non-specific adsorption onto GEC is almost non-existent even when the surface has not been treated by blocking reagents. The analytical signal obtained was higher when compared with other electrochemical genosensors. Results can be achieved in 150 min, and the detection limit is in the order of fmol. Additionally, surface regeneration is possible using a simple polishing procedure, allowing for multiple use. The new genosensor based on GEC fulfils the requirements desired for these devices: ease of preparation as dry-adsorption of DNA is very simple and easily automated, robustness, sensitivity, low cost of production, ease of miniaturisation and simple use and fast response. Additionally, it can be used for field measurements and can be produced as a genosensor kit. Also, this material can be implemented for screen-printing procedures for the mass production of genosensors. The utility of the genosensor based on GEC is also illustrated with the detection of a sequence related to novel determinant of beta-lactamase resistance in Staphylococcus aureus.

Adsorption↗

Carbon composite electrodes: surface and electrochemical properties.

Electrodes based on particulate carbon-epoxy or silicone composites have been formed and characterised using electrochemical methods, scanning electron microscopy and scanning electrochemical microscopy. These composites are rigid, exhibit high electrical conductivity and are stable in organic solvents for prolonged periods. The bulk resistance of the Araldite-M and Araldite-CW2215 based electrodes is low, 130+/-12 and 185+/-15 ohms, respectively. In contrast, the bulk resistance of the silicone based electrodes is 1480+/-112 ohms. The uncompensated resistance of electrochemical cells where the composites act as working electrodes is significantly larger than that expected on the basis of solution resistance alone, i.e., up to 7.5 kohms in the case of the silicone composites. These results are interpreted in terms of the presence of pores within the composite material. The response times of the composite electrodes to changes in the applied potential is between 3.1 and 7.2 ms which, although almost an order of magnitude longer than a comparable glassy carbon electrode, is sufficiently rapid to give useful voltammetric data for scan rates of several V s(-1). Close to ideal reversible cyclic voltammetry is observed for ferrocene under semi-infinite diffusion control for scan rates between 0.01 and 0.1 V s(-1) at the Araldite composites. In contrast, the large resistance associated with the silicone based materials causes quasi-reversible responses to be observed over this range of scan rate. Scan rate dependent cyclic voltammetry and time resolved chronoamperometry responses observed for ferrocene in solution are consistent with those expected for a random array of microelectrodes. Scanning electron microscopy and scanning electrochemical microscopy has been used to image the shape, size and electrochemical activity of the electroactive zones. In the case of Araldite-M, the quality of the electrode surface has been probed by comparing the rate of heterogeneous electron transfer at a composite microelectrode with that found for a carbon fibre electrode. The standard heterogeneous electron transfer rate constant, k degrees , is 6.0+/-0.1 x 10(-3) cm s(-1) for the composite compared to 1.5+/-0.1 x 10(-1) cm s(-1) for the carbon fibre electrode. While the smaller rate constant found for the composite suggests a less pristine surface, k degrees is sufficiently large to support reversible, electron transfer under typical electroanalytical conditions. These fundamental measurements will underpin the development of enzyme based biosensors for use in organic solvents.

Journal Article↗