PubMed Health⌕ Search

Biomedical subjects

Salvador Olmos

Publications and source records attributed to Salvador Olmos.

7 recordsLinked to original sources

Assessment of QT-measurement accuracy using the 12-lead electrocardiogram derived from EASI leads.

The purpose of the present study is to assess QT-interval measurements from the EASI 12-lead electrocardiogram (ECG) as compared with the standard 12-lead ECG. The QT interval was automatically determined in simultaneously recorded standard and EASI 12-lead ECGs, using a validated wavelet-based delineator. The agreement between the 2 sets of measurements was quantified both on a lead-by-lead basis and a multilead basis with global definitions of QRS onset and T-wave end. The results show that the agreement between QT-interval measurements from the 2 lead systems is acceptable, with negligible mean differences and with correlation coefficients ranging from 0.91 to 0.98 depending on the lead studied. Although the SD shows a clear dependence on the selected lead (ranging from 9.2 to 26.4 milliseconds), differences are within the accepted tolerances for automatic delineation. In a few patients, large differences were found, mainly because of changes in morphology present in both lead systems. QT intervals measured by the multilead approach were considerably more stable than single-lead measurements and resulted in a much better agreement between the 2 lead systems (correlation coefficient, 0.98; QT difference, 1.1 +/- 9.8 milliseconds). Thus, the EASI 12-lead ECG may be used for reliable QT monitoring when the multilead delineation approach is adopted.

Diagnosis, Computer-Assisted↗

Wavelet-based event detection in implantable cardiac rhythm management devices.

This paper presents a novel event detector for implantable devices. The algorithm is based on a signal model which describes an event as a linear combination of basis functions. The linear combination involves two fundamental electrogram waveforms represented at different time scales. An efficient, low-complexity detector is developed using the dyadic wavelet transform with integer filter coefficients, and a generalized likelihood ratio test. The results show that reliable detection is obtained at an intermediate signal-to-noise ratio (SNR = 25 dB) for various common noise sources. In terms of probabilities of missed events and false alarms, an over-all performance of 0.7% and 0.1%, respectively, was achieved on electrograms corrupted by the different noise types at an intermediate SNR.

Algorithms↗

Characterization of repolarization alternans during ischemia: time-course and spatial analysis.

T-wave alternans (TWA) has been linked to increased vulnerability to ventricular fibrillation in different settings including myocardial ischemia. In this study, we propose a methodology for the characterization of TWA induced by transient, regional ischemia. We studied the prevalence, magnitude and spatio-temporal relationship between TWA and ischemia in 95 patients undergoing percutaneous transluminal coronary angioplasty (PTCA). Two electrocardiogram records of each patient, a control recording before PTCA and the PTCA record, were analyzed using a robust, recently proposed method for TWA analysis. The detected episodes were characterized in terms of their time-course, lead distribution and alternans waveform. One third of the patients (33.7%) showed TWA episodes during PTCA. The highest prevalence (51.7%) and amplitude were found in patients with left anterior descendent artery occlusion. The onset of TWA was detected after the first 1-2 min of occlusion, suggesting that some level of ischemia must be attained before TWA arises, while disappearance of TWA following reperfusion was much more rapid. The TWA lead distributions and waveforms showed distinct distributions according to the occluded artery reflecting the regional nature of the TWA phenomenon.

Adult↗

Enhanced real-time ECG coder for packetized telecardiology applications.

A new real-time compression method for electrocardiogram (ECG) signals has been developed based on the wavelet transform approach. The method is specifically adaptable for packetized telecardiology applications. The signal is segmented into beats and a beat template is subtracted from them, producing a residual signal. Beat templates and residual signals are coded with a wavelet expansion. Compression is achieved by selecting a subset of wavelet coefficients. The number of selected coefficients depends on a threshold which has different definitions depending on the operational mode of the coder. Compression performance has been tested using a subset of ECG records from MIT-BIH Arrhythmia database. This method has been designed for real-time packetized telecardiology scenarios both in wired and wireless environments.

Algorithms↗

Methodological principles of T wave alternans analysis: a unified framework.

Visible T wave alternans (TWA) in the electrocardiogram (ECG) had been regarded as an infrequent phenomenon during the first 80 years of electrocardiography. Nevertheless, computerized analysis changed this perception. In the last two decades, a variety of techniques for automatic TWA analysis have been proposed. These techniques have allowed researchers to detect nonvisible TWA in a wide variety of clinical and experimental conditions. Such studies have recently shown that TWA is related to cardiac instability and increased arrhythmogenicity. Comparison of TWA analysis methods is a difficult task due to the diversity of approaches. In this paper, we propose a unified framework which holds the existing methods. In the light of this framework, the methodological principles of the published TWA analysis schemes are compared and discussed. This framework may have an important role to develop new approaches to this problem.

Algorithms↗

A wavelet-based ECG delineator: evaluation on standard databases.

In this paper, we developed and evaluated a robust single-lead electrocardiogram (ECG) delineation system based on the wavelet transform (WT). In a first step, QRS complexes are detected. Then, each QRS is delineated by detecting and identifying the peaks of the individual waves, as well as the complex onset and end. Finally, the determination of P and T wave peaks, onsets and ends is performed. We evaluated the algorithm on several manually annotated databases, such as MIT-BIH Arrhythmia, QT, European ST-T and CSE databases, developed for validation purposes. The QRS detector obtained a sensitivity of Se = 99.66% and a positive predictivity of P+ = 99.56% over the first lead of the validation databases (more than 980,000 beats), while for the well-known MIT-BIH Arrhythmia Database, Se and P+ over 99.8% were attained. As for the delineation of the ECG waves, the mean and standard deviation of the differences between the automatic and manual annotations were computed. The mean error obtained with the WT approach was found not to exceed one sampling interval, while the standard deviations were around the accepted tolerances between expert physicians, outperforming the results of other well known algorithms, especially in determining the end of T wave.

Algorithms↗

Remote processing server for ECG-based clinical diagnosis support.

In this paper, we present the development of a remote server that provides a user-friendly access to advanced electrocardiographic (ECG) signal processing techniques. The prototype supplies telemedicine facilities to doctors for clinical indexes remote computation to support diagnosis through the Internet. The user-friendly interface is based on the selection of the desired ECG signal processing tools on a Web browser window. The centralized structure of the system permits unique and user-independent update and management of the software and, therefore, is especially suitable for remote or rural regions to have access to the new ECG information techniques.

Algorithms↗