PubMed Health⌕ Search

Biomedical subjects

Saly Romero-Torres

Publications and source records attributed to Saly Romero-Torres.

4 recordsLinked to original sources

Raman spectroscopy for tablet coating thickness quantification and coating characterization in the presence of strong fluorescent interference.

We report a novel approach to the measurement of colored tablet coating thickness, which employs Raman spectroscopy with univariate and multivariate data analysis. Our results suggest that Raman sensing can serve as a viable non-invasive means to quantify tablet coating thickness in the presence of a fluorescent ingredient in the coating formulation (food colorant Alphazurine FG or D&C Blue No. 4). This study comparatively tests the advantage of several data transformation approaches, including mean centering, standard normal variate, and Savitzky-Golay smoothed second derivative as means of improving predictive models in the presence of fluorescence. By application of the partial least squares (PLS) calibration algorithm to establish optimum covariance between transformed spectral data and measured tablet coating thicknesses, we have been able to create predictive models with calibration errors as small as 4 microm for a training set that spans colored coating thicknesses from 50 to 151 microm.

Algorithms↗

On-line content uniformity determination of tablets using low-resolution Raman spectroscopy.

Analytical techniques for rapid and nondestructive content uniformity determination of pharmaceutical solid dosage forms have been studied for several years in an effort to replace the traditional wet chemistry procedures, which are labor intensive and time consuming. Both Raman spectroscopy and near-infrared spectroscopy have been used for this purpose, and predictability errors are approaching those of the traditional techniques. In this study, a low-resolution Raman spectrometer was utilized to demonstrate the feasibility of both rapid at-line and on-line determination of tablet content uniformity. Additionally, sampling statistics were reviewed in an effort to determine how many tablets should be assayed for specific batch sizes. A good correlation was observed between assay values determined by high-performance liquid chromatography and Raman analysis. Due to rapid acquisition times for the Raman data, it was possible to analyze far more samples than with wet chemistry methods, leading to a better statistical description of variation within the batch. For at-line experiments, the sampling volume was increased by rotating the laser beam during the acquisition period. For the on-line experiments, the sampling volume was increased by sampling from a stream of tablets moving underneath the Raman probe on a conveyor system. Finally, an approach is proposed for monitoring content uniformity immediately following the compaction process. In conclusion, Raman spectroscopy has potential as a rapid, nondestructive technique for at- or on-line determination of tablet content uniformity.

Algorithms↗

Raman spectroscopic measurement of tablet-to-tablet coating variability.

We report new results suggesting the feasibility of Raman spectrometry as a tool by which to examine the variability of tablet coatings. Our experiments feature a probe that can operate with a revolving laser focus to average content and coating non-uniformity. Raman spectral changes are correlated with tablet exposure times in a pan coater by means of partial least squares (PLS) multivariate analysis. Statistical models are found to be improved by pre-processing schemes that emphasize spectral changes while minimizing the effects of background light scattering and fluorescence. These pre-processing techniques include multiplicative scatter correction (MSC) and standard normal variate (SNV) transformation, used in concert with Savitzky-Golay second derivative smoothing (SGSD). The two approaches give comparable results yielding R2 values for PLS calibration and cross-calibrated prediction variance regression of 0.999 and 0.997, respectively. Correlation results and model residual values demonstrate that Raman spectroscopy serves sensitively to reflect the coating thickness of the tablets studied.

Algorithms↗

Blend uniformity analysis using stream sampling and near infrared spectroscopy.

A near infrared spectroscopic method was developed to determine drug content in a 20% (wt/wt) ibuprofen and spray-dried hydrous lactose blend. A blending profile was obtained after blending for 0.5, 1, 3, 5, 10, and 20 minutes. Stream sampling was used to collect about 20 blend samples at each of the blending times from a laboratory scale V-blender. The samples collected were used to develop a near infrared calibration model. The calibration model was then used to determine the drug content of unknown samples from 2 validation blends. The validation blends were not included in the calibration model; they were used to evaluate the effectiveness of the calibration model. A total of 45 samples from the 2 validation blends were predicted by the near infrared calibration model and then analyzed by a validated UV spectrophotometric method. The root mean square error of prediction for the first validation blend was 5.69 mg/g and 3.30 mg/g for the samples from the second blend. A paired t test at the 95% confidence level did not indicate any differences between the drug content predicted by the near infrared spectroscopy (NIRS) method and the validated UV method for the 2 blends. The results show that the NIRS method could be developed while the blending profile is generated and used to thoroughly characterize a new formulation during development by analyzing a large number of samples. The new formulation could be transferred to a manufacturing plant with an NIRS method to facilitate blend uniformity analysis.

Calibration↗