PubMed Health⌕ Search

Biomedical subjects

Sam Page

Publications and source records attributed to Sam Page.

4 recordsLinked to original sources

Direct molecular haplotyping of the IVS-8 poly(TG) and polyT repeat tracts in the cystic fibrosis gene by melting curve analysis of hybridization probes.

BACKGROUND: Molecular haplotyping is a developing technology with great potential for use in clinical diagnostics. We describe a haplotyping method that uses PCR combined with hybridization probes. METHODS: We designed a LightCycler assay that uses fluorescence resonance energy transfer hybridization probes to haplotype the poly(TG) and polyT (TG-T) tract in the IVS-8 region of the CFTR gene. The reporter probe was designed as a perfect match to the TG12-5T allele. RESULTS: Analysis of 132 samples revealed 9 unique derivative melting temperatures (Tms); the lowest was 42.4 degrees C and the highest was 63.6 degrees C. The lowest Tms were in the TGn-9T group, the intermediate Tms in the TGn-7T group, and the highest Tms in the TGn-5T group. Haplotype frequencies were highest (39%) for TG11-7T and lowest (0.4%) for TG13-5T. CONCLUSIONS: Different combinations of polymorphisms under the reporter hybridization probe had unique and characteristic Tms. This property enables genotyping as well as determination of the phase of multiple variants under the probe, a principle we demonstrated by haplotyping the TG-T repeat tract in the IVS-8 region of the CFTR gene.

Cystic Fibrosis↗

Single-tube method for nucleic acid extraction, amplification, purification, and sequencing.

BACKGROUND: The hepatitis C virus (HCV) genotype determines patient prognosis and duration of treatment, but sequencing of the gene is lengthy and labor-intensive. We used a commercially available nucleic acid extraction system to develop a single-tube extraction-to-sequencing (STETS) method for HCV genotyping. METHODS: HCV RNA was purified and amplified in tubes coated with a solid-phase matrix that irreversibly bound nucleic acid during the extraction step. After reverse transcription-PCR, the amplicon was adsorbed to the original extraction matrix for purification and use in the subsequent sequencing reactions. RESULTS: The STETS method generated genotyping-quality sequence for a range of HCV titers from 500 to 6,000,000 IU/mL. If a viral sample was detected during real-time reverse transcription-PCR, it could be sequenced and genotyped. Read lengths >600 bases were observed with the STETS method. Mixed infections were detected and genotyped if at least 15% of the minor species was present. Combining the STETS method with consecutive sequencing provided a means of performing both forward and reverse sequencing in a single tube. CONCLUSIONS: A single-tube nucleic acid extraction-to-sequencing method, which requires less time and labor than conventional methods, generates HCV sequence data that are equivalent to conventional methods and can be used to genotype HCV.

Genotype↗

Hepatitis C genotyping by denaturing high-performance liquid chromatography.

Determination of the hepatitis C virus (HCV) genotype for infected patients increasingly has become accepted as the standard of care. Genotype assignment helps in assessing disease prognosis and assists in establishing the appropriate duration of treatment. The great genetic diversity of HCV, with 11 major genotypes and >70 subtypes, contributes to the technical difficulty of genotype testing. While the "gold standard" for testing is nucleic acid sequencing, a variety of hybridization assays, including the line probe assay, have been developed to provide more rapid and accessible forms of testing. The aim of this study was to determine whether denaturing high-performance liquid chromatography (dHPLC) could be used as a clinical method for distinguishing HCV genotypes 1, 2, 3, and 4. A portion of the 5' untranslated region of the HCV genome was amplified by heminested multiplex reverse transcription PCR. The two amplicons then were analyzed by dHPLC analysis and compared to the genotypes determined by sequence analysis. After 115 specimens were analyzed as standards, 200 masked specimens (specimens whose identity was not known before testing) were analyzed to determine the concordance of the assay. The assay had a concordance of 96% at the genotype level and a concordance of 87% at the subtype level. However, the dHPLC method was not as accurate as other reported methods of HCV genotyping. This is the first time that HCV genotyping has been performed by dHPLC.

5' Untranslated Regions↗