PubMed Health⌕ Search

Biomedical subjects

Samuel A Wickline

Publications and source records attributed to Samuel A Wickline.

At least 37 records · Page 2Linked to original sources

Acoustic characterization in whole blood and plasma of site-targeted nanoparticle ultrasound contrast agent for molecular imaging.

The ability to enhance specific molecular markers of pathology with ultrasound has been previously demonstrated by our group employing a nanoparticle contrast agent [Lanza et al., Invest. Radiol. 35, 227-234 (2000); Ultrasound Med. Biol. 23, 863-870 (1997)]. One of the advantages of this agent is very low echogenicity in the blood pool that allows increased contrast between the blood pool and the bound, site-targeted agent. We measured acoustic backscatter and attenuation coefficient as a function of the contrast agent concentration, ambient pressure, peak acoustic pressure, and as an effect of duty cycle and wave form shape. Measurements were performed while the nanoparticles were suspended in either whole porcine blood or plasma. The nanoparticles were only detectable when insonified within plasma devoid of red blood cells and were shown to exhibit backscatter levels more than 30 dB below the backscatter from whole blood. Attenuation of nanoparticles in whole porcine blood was not measurably different from that of whole blood alone over a range of concentrations up to eight times the maximum in vivo dose. The resulting data provide upper bounds on blood pool attenuation coefficient and backscatter and will be needed to more precisely define levels of molecular contrast enhancement that may be obtained in vivo.

Animals↗

Regional ventricular wall thickening reflects changes in cardiac fiber and sheet structure during contraction: quantification with diffusion tensor MRI.

Dynamic changes of myocardial fiber and sheet structure are key determinants of regional ventricular function. However, quantitative characterization of the contraction-related changes in fiber and sheet structure has not been reported. The objective of this study was to quantify cardiac fiber and sheet structure at selected phases of the cardiac cycle. Diffusion tensor MRI was performed on isolated, perfused Sprague-Dawley rat hearts arrested or fixed in three states as follows: 1) potassium arrested (PA), which represents end diastole; 2) barium-induced contracture with volume (BV+), which represents isovolumic contraction or early systole; and 3) barium-induced contracture without volume (BV-), which represents end systole. Myocardial fiber orientations at the base, midventricle, and apex were determined from the primary eigenvectors of the diffusion tensor. Sheet structure was determined from the secondary and tertiary eigenvectors at the same locations. We observed that the transmural distribution of the myofiber helix angle remained unchanged as contraction proceeded from PA to BV+, but endocardial and epicardial fibers became more longitudinally orientated in the BV- group. Although sheet structure exhibited significant regional variations, changes in sheet structure during myocardial contraction were relatively uniform across regions. The magnitude of the sheet angle, which is an index of local sheet slope, decreased by 23 and 44% in BV+ and BV- groups, respectively, which suggests more radial orientation of the sheet. In summary, we have shown for the first time that geometric changes in both sheet and fiber orientation provide a substantial mechanism for radial wall thickening independent of active components due to myofiber shortening. Our results provide direct evidence that sheet reorientation is a primary determinant of myocardial wall thickening.

Animals↗

Magnetic resonance nanoparticles for cardiovascular molecular imaging and therapy.

Molecular vascular imaging represents a novel tool that promises to change the current medical paradigm of 'see and treat' to a 'detect and prevent' strategy. Nanoparticle agents, such as superparamagnetic nanoparticles and perfluorocarbon nanoparticle emulsions, have been developed for noninvasive imaging, particularly for magnetic resonance imaging. Designed to target specific epitopes in tissues, these agents are beginning to enter clinical trials for cardiovascular applications. The delivery of local therapy with these nanoparticles, using mechanisms such as contact-facilitated drug delivery, is in the advanced stages of preclinical research. Ultimately, combined diagnostic and therapeutic nanoparticle formulations may allow patients to be characterized noninvasively and segmented to receive custom-tailored therapy. This review focuses on recent developments of nanoparticle technologies with an emphasis on cardiovascular applications of magnetic resonance imaging.

Animals↗

Quantification of stenotic mitral valve area with magnetic resonance imaging and comparison with Doppler ultrasound.

OBJECTIVES: The purpose of this study was to evaluate the reliability of the pressure half-time (PHT) method for estimating mitral valve areas (MVAs) by velocity-encoded cardiovascular magnetic resonance (VE-CMR) and to compare the method with paired Doppler ultrasound. BACKGROUND: The pressure half-time Doppler echocardiography method is a practical technique for clinical evaluation of mitral stenosis. As CMR continues evolving as a routine clinical tool, its use for estimating MVA requires thorough evaluation. METHODS: Seventeen patients with mitral stenosis underwent echocardiography and CMR. Using VE-CMR, MVA was estimated by PHT method. Additionally, peak E and peak A velocities were defined. Interobserver repeatability of VE-CMR was evaluated. RESULTS: By Doppler, MVAs ranged from 0.87 to 4.49 cm2; by CMR, 0.91 to 2.70 cm2, correlating well between modalities (r = 0.86). The correlation coefficient for peak E and peak A between modalities was 0.81 and 0.89, respectively. Velocity-encoded CMR data analysis provided robust, repeatable estimates of peak E, peak A, and MVA (r = 0.99, 0.99, and 0.96, respectively). CONCLUSIONS: Velocity-encoded cardiovascular magnetic resonance can be used routinely as a robust tool to quantify MVA via mitral flow velocity analysis with PHT method.

Aged↗

Targeted nanoparticles for quantitative imaging of sparse molecular epitopes with MRI.

Before molecular imaging with MRI can be applied clinically, certain problems, such as the potential sparseness of molecular epitopes on targeted cell surfaces, and the relative weakness of conventional targeted MR contrast agents, must be overcome. Accordingly, the conditions for diagnostic conspicuity that apply to any paramagnetic MRI contrast agent with known intrinsic relaxivity were examined in this study. A highly potent paramagnetic liquid perfluorocarbon nanoparticle contrast agent ( approximately 250 nm diameter, >90,000 Gd3+/particle) was imaged at 1.5 T and used to successfully predict a range of sparse concentrations in experimental phantoms with the use of standard MR signal models. Additionally, we cultured and targeted the smooth muscle cell (SMC) monolayers that express "tissue factor," a glycoprotein of crucial significance to hemostasis and response to vascular injury, by conjugating an anti-tissue factor antibody fragment to the nanoparticles to effect specific binding. Quantification of the signal from cell monolayers imaged at 1.5 T demonstrated, as predicted via modeling, that only picomolar concentrations of paramagnetic perfluorocarbon nanoparticles were required for the detection and quantification of tissue factor at clinical field strengths. Thus, for targeted paramagnetic agents carrying high payloads of gadolinium, it is possible to quantify molecular epitopes present in picomolar concentrations in single cells with routine MRI.

Analysis of Variance↗

Harmonic phase MR tagging for direct quantification of Lagrangian strain in rat hearts after myocardial infarction.

The utility of harmonic phase (HARP) analysis was recently demonstrated in humans and large animals as a technique for rapid and automatic analysis of tagged magnetic resonance images. In the current study, the applicability and accuracy of HARP analysis for automatic strain quantification in small animals were investigated. A validation study was performed on seven postinfarct rats and seven age-matched controls. A method for direct computation of 2D Lagrangian strain fields from spatial derivatives of HARP images was also developed in this paper. The results of HARP analysis were evaluated by comparison with those of homogeneous strain analysis employing finite element method and manual tag tracking. Both methods were validated with simulated digital images. Compared to conventional homogeneous strain analysis, HARP analysis yielded similar results in the assessment of regional strain patterns in both control and infarct rats. Both methods detected a reduction in maximal stretch and shortening in infarct rats. Our results suggest that HARP analysis can also be applied to quantify alterations in regional myocardial wall motion in small animals.

Animals↗

Quantitative "magnetic resonance immunohistochemistry" with ligand-targeted (19)F nanoparticles.

Unstable atherosclerotic plaques exhibit microdeposits of fibrin that may indicate the potential for a future rupture. However, current methods for evaluating the stage of an atherosclerotic lesion only involve characterizing the level of vessel stenosis, without delineating which lesions are beginning to rupture. Previous work has shown that fibrin-targeted, liquid perfluorocarbon nanoparticles, which carry a high payload of gadolinium, have a high sensitivity and specificity for detecting fibrin with clinical (1)H MRI. In this work, the perfluorocarbon content of the targeted nanoparticles is exploited for the purposes of (19)F imaging and spectroscopy to demonstrate a method for quantifiable molecular imaging of fibrin in vitro at 4.7 T. Additionally, the quantity of bound nanoparticles formulated with different perfluorocarbon species was calculated using spectroscopy. Results indicate that the high degree of nanoparticle binding to fibrin clots and the lack of background (19)F signal allow accurate quantification using spectroscopy at 4.7 T, as corroborated with proton relaxation rate measurements at 1.5 T and trace element (gadolinium) analysis. Finally, the extension of these techniques to a clinically relevant application, the evaluation of the fibrin burden within an ex vivo human carotid endarterectomy sample, demonstrates the potential use of these particles for uniquely identifying unstable atherosclerotic lesions in vivo.

Arteriosclerosis↗

Successful performance of Cox-Maze procedure on beating heart using bipolar radiofrequency ablation: a feasibility study in animals.

BACKGROUND: The Cox-Maze procedure is the gold standard for the surgical treatment of atrial fibrillation with proven long-term efficacy. However, its application has been limited by its complexity and significant morbidity. The purpose of this study was to test the feasibility and safety of performing the Cox-Maze procedure using bipolar radiofrequency ablation on the beating heart without cardiopulmonary bypass. METHODS: After median sternotomy, 6 Hanford mini-pigs underwent a modified Cox-Maze procedure using bipolar radiofrequency energy. The animals survived for 30 days. Atrial function, coronary artery, pulmonary vein anatomy, and valve function were assessed by magnetic resonance imaging. At reoperation, pacing documented electrical isolation of the pulmonary veins. Induction of atrial fibrillation was attempted by burst pacing with cholinergic stimulation. Histologic assessment was performed after sacrifice. RESULTS: There were no perioperative mortalities or neurologic events. At 30 days, atrial fibrillation was unable to be induced, and pulmonary vein isolation was confirmed by pacing. Magnetic resonance imaging assessment revealed no coronary artery or pulmonary vein stenoses. Although atrial ejection fraction decreased slightly from 0.344 +/- 0.0114 to 0.300 +/- 0.055 (p = 0.18), atrial contractility was preserved in every animal. Histologic assessment showed all lesions to be transmural, and there were no significant stenoses of the coronary vessels or injuries to the valves. CONCLUSIONS: Virtually all of the lesions of the Cox-Maze procedure can be performed without cardiopulmonary bypass using bipolar radiofrequency energy. There were no late stenoses of the pulmonary veins. Clinical trials of this new technology on the beating heart are warranted.

Animals↗

A prospective multicenter trial of bipolar radiofrequency ablation for atrial fibrillation: early results.

BACKGROUND: The Cox-Maze III remains the gold standard for the surgical treatment of atrial fibrillation. However, the "cut-and-sew" technique is time consuming and technically challenging. The pulmonary veins are the source of ectopy in the majority of patients with atrial fibrillation. The safety and efficacy of bipolar radiofrequency to electrically isolate the pulmonary veins was evaluated in a prospective multi-center trial. METHODS: Beginning in January 2002, 30 patients at three medical centers underwent pulmonary vein isolation using bipolar radiofrequency and were followed for 6 months. Twenty-four of the patients also underwent a modified Cox-Maze III. Electrical isolation of the pulmonary veins was confirmed with intraoperative pacing. Pulmonary vein patency was assessed by magnetic resonance imaging or three-dimensional computed tomography in 15 patients at 1 month. RESULTS: Mean age was 60.9 +/- 11.7 years. Nineteen patients had paroxysmal atrial fibrillation. All pulmonary veins were isolated in every patient. The left pulmonary veins underwent 3.0 +/- 1.4 applications for a total of 26.4 +/- 10.5 seconds. The right pulmonary veins underwent 2.8 +/- 1.1 applications for a total of 26.3 +/- 12.6 seconds. There was no operative mortality. At 1 month, imaging revealed no evidence of pulmonary vein stenosis. At 6 months, 96% of patients were in normal sinus rhythm. CONCLUSIONS: The use of bipolar radiofrequency for electrical isolation of pulmonary veins and to replace other Cox-Maze III incisions is safe and effective at controlling atrial fibrillation. This emerging technology may shorten and simplify the surgical management of atrial fibrillation.

Aged↗

Clinical utility of rapid prescreening magnetic resonance angiography of peripheral vascular disease prior to cardiac catheterization.

PURPOSE: The presence of peripheral vascular disease, in particular iliofemoral disease, is responsible in part for vascular complications from femoral artery cannulation. We investigated whether prescreening for vascular obstructions with magnetic resonance angiography (MRA) in high-risk patients with peripheral vascular disease (PVD) would provide useful information to angiographers seeking to improve the safety and efficiency of femoral artery access at cardiac catheterization. METHODS: Twelve consecutive patients with known or suspected PVD underwent contrast-enhanced, aorto-iliofemoral MRA using a real-time BolusTrak technique. Contrast-to-noise ratios for each patient were calculated. The cardiac angiographer reviewed the MRA prior to catheterization and selected an access site. The patients' subsequent clinical course was evaluated, and a postprocedure questionnaire was completed by the angiographer to define the value of the prescreening MRA. RESULTS: No significant vascular complications occurred in these patients as defined by failure of initially chosen access site, arterial dissection, limb ischemia, pseudoaneurysm formation, hemorrhage (including retroperitoneal hematoma), or need for blood transfusion or emergency vascular surgical repair. Statistical frequency analysis of the responses in the postprocedure questionnaire demonstrated that the MR data were clinically valuable in (1) influencing the initial choice of access site; (2) influencing technical alterations to the standard access; and, (3) enhancing confidence in the selection of access site. CONCLUSIONS: MRA prescreening in patients with PVD is an effective, novel adjunct to cardiac catheterization in selected patients that improves physician confidence and influences technical choices during coronary angiography from the femoral artery approach.

Adult↗

Ultrasonic delineation of aortic microstructure: the relative contribution of elastin and collagen to aortic elasticity.

Aortic elasticity is an important factor in hemodynamic health, and compromised aortic compliance affects not only arterial dynamics but also myocardial function. A variety of pathologic processes (e.g., diabetes, Marfan's syndrome, hypertension) can affect aortic elasticity by altering the microstructure and composition of the elastin and collagen fiber networks within the tunica media. Ultrasound tissue characterization techniques can be used to obtain direct measurements of the stiffness coefficients of aorta by measurement of the speed of sound in specific directions. In this study we sought to define the contributions of elastin and collagen to the mechanical properties of aortic media by measuring the magnitude and directional dependence of the speed of sound before and after selective isolation of either the collagen or elastin fiber matrix. Formalin-fixed porcine aortas were sectioned for insonification in the circumferential, longitudinal, or radial direction and examined using high-frequency (50 MHz) ultrasound microscopy. Isolation of the collagen or elastin fiber matrices was accomplished through treatment with NaOH or formic acid, respectively. The results suggest that elastin is the primary contributor to aortic medial stiffness in the unloaded state, and that there is relatively little anisotropy in the speed of sound or stiffness in the aortic wall.

Algorithms↗

Novel paramagnetic contrast agents for molecular imaging and targeted drug delivery.

Molecular biology and genomic sciences are revealing the early biological signatures for many diseases. In response, the Molecular Imaging community is rapidly developing contrast agents to visualize the nascent pathological changes and to concomitantly deliver treatment directly to the site of disease. The evaluation, development and use of these new agents require a complementary understanding of contrast chemistry and imaging techniques. The fundamental issues surrounding magnetic contrast agent development, rational drug delivery, MR molecular imaging, and their interdependence are elucidated.

Animals↗

Recommendations of the National Heart, Lung, and Blood Institute Nanotechnology Working Group.

Recent rapid advances in nanotechnology and nanoscience offer a wealth of new opportunities for diagnosis and therapy of cardiovascular, pulmonary, and hematologic diseases and sleep disorders. To review the challenges and opportunities offered by these nascent fields, the National Heart, Lung, and Blood Institute convened a Working Group on Nanotechnology. Working Group participants discussed the various aspects of nanotechnology and its applications to heart, lung, blood, and sleep (HLBS) diseases. This report summarizes their discussions according to scientific opportunities, perceived needs and barriers, specific disease examples, and recommendations on facilitating research in the field. An overarching recommendation of the Working Group was to focus on translational applications of nanotechnology to solve clinical problems. The Working Group recommended the creation of multidisciplinary research centers capable of developing applications of nanotechnology and nanoscience to HLBS research and medicine. Centers would also disseminate technology, materials, and resources and train new investigators. Individual investigators outside these centers should be encouraged to conduct research on the application of nanotechnology to biological and clinical problems. Pilot programs and developmental research are needed to attract new investigators and to stimulate creative, high-impact research. Finally, encouragement of small businesses to develop nanotechnology-based approaches to clinical problems was considered important.

Animals↗

Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis: comparison with echocardiography.

BACKGROUND: Valvular pathology can be analyzed quickly and accurately through the use of Doppler ultrasound. For aortic stenosis, the continuity equation approach with Doppler velocity-time integral (VTI) data is by far the most commonly used clinical method of quantification. In view of the emerging popularity of cardiac magnetic resonance (CMR) as a routine clinical imaging tool, the purposes of this study were to define the reliability of velocity-encoded CMR as a routine method for quantifying stenotic aortic valve area, to compare this method with the accepted standard, and to evaluate its reproducibility. METHODS AND RESULTS: Patients (n=24) with aortic stenosis (ranging from 0.5 to 1.8 cm2) were imaged with CMR and echocardiography. Velocity-encoded CMR was used to obtain velocity information in the aorta and left ventricular outflow tract. From this flow data, pressure gradients were estimated by means of the modified Bernoulli equation, and VTIs were calculated to estimate aortic valve orifice dimensions by means of the continuity equation. The correlation coefficients between modalities for pressure gradients were r=0.83 for peak and r=0.87 for mean. The measurements of VTI correlated well, leading to an overall strong correlation between modalities for the estimation of valve dimension (r=0.83, by means of the identified best approach). For 5 patients, the CMR examination was repeated using the best approach. The repeat calculations of valve size correlated well (r=0.94). CONCLUSIONS: Velocity-encoded CMR can be used as a reliable, user-friendly tool to evaluate stenotic aortic valves. The measurements of pressure gradients, VTIs, and the valve dimension correlate well with the accepted standard of Doppler ultrasound.

Adult↗

Molecular imaging of angiogenesis in early-stage atherosclerosis with alpha(v)beta3-integrin-targeted nanoparticles.

BACKGROUND: Angiogenesis is a critical feature of plaque development in atherosclerosis and might play a key role in both the initiation and later rupture of plaques that lead to myocardial infarction and stroke. The precursory molecular or cellular events that initiate plaque growth and that ultimately contribute to plaque instability, however, cannot be detected directly with any current diagnostic modality. METHODS AND RESULTS: Atherosclerosis was induced in New Zealand White rabbits fed 1% cholesterol for approximately 80 days. alpha(v)beta3-Integrin-targeted, paramagnetic nanoparticles were injected intravenously and provided specific detection of the neovasculature within 2 hours by routine magnetic resonance imaging (MRI) at a clinically relevant field strength (1.5 T). Increased angiogenesis was detected as a 47+/-5% enhancement in MRI signal averaged throughout the abdominal aortic wall among rabbits that received alpha(v)beta3-targeted, paramagnetic nanoparticles. Pretreatment of atherosclerotic rabbits with alpha(v)beta3-targeted, nonparamagnetic nanoparticles competitively blocked specific contrast enhancement of the alpha(v)beta3-targeted paramagnetic agent. MRI revealed a pattern of increased alpha(v)beta3-integrin distribution within the atherosclerotic wall that was spatially heterogeneous along both transverse and longitudinal planes of the abdominal aorta. Histology and immunohistochemistry confirmed marked proliferation of angiogenic vessels within the aortic adventitia, coincident with prominent, neointimal proliferation among cholesterol-fed, atherosclerotic rabbits in comparison with sparse incidence of neovasculature in the control animals. CONCLUSIONS: This molecular imaging approach might provide a method for defining the burden and evolution of atherosclerosis in susceptible individuals as well as responsiveness of individual patients to antiatherosclerotic therapies.

Animals↗

Molecular imaging of angiogenesis in nascent Vx-2 rabbit tumors using a novel alpha(nu)beta3-targeted nanoparticle and 1.5 tesla magnetic resonance imaging.

Early noninvasive detection and characterization of solid tumors and their supporting neovasculature is a fundamental prerequisite for effective therapeutic intervention, particularly antiangiogenic treatment regimens. Emerging molecular imaging techniques now allow recognition of early biochemical, physiological, and anatomical changes before manifestation of gross pathological changes. Although new tumor, vascular, extracellular matrix, and lymphatic biomarkers continue to be discovered, the alpha(nu)beta(3)-integrin remains an attractive biochemical epitope that is highly expressed on activated neovascular endothelial cells and essentially absent on mature quiescent cells. In this study, we report the first in vivo use of a magnetic resonance (MR) molecular imaging nanoparticle to sensitively detect and spatially characterize neovascularity induced by implantation of the rabbit Vx-2 tumor using a common clinical field strength (1.5T). New Zealand White rabbits (2 kg) 12 days after implantation of fresh Vx-2 tumors (2 x 2 x 2 mm(3)) were randomized into one of three treatment groups: (a) alpha(nu)beta(3)-targeted, paramagnetic formulation; (b) nontargeted, paramagnetic formulation; and (c) alpha(nu)beta(3)-targeted nonparamagnetic nanoparticles followed by (2 h) the alpha(nu)beta(3)-targeted, paramagnetic formulation to competitively block magnetic resonance imaging (MRI) signal enhancement. After i.v. systemic injection (0.5 ml of nanoparticles/kg), dynamic T(1)-weighted MRI was used to spatially and temporally determine nanoparticle deposition in the tumor and adjacent tissues, including skeletal muscle. At 2-h postinjection, alpha(nu)beta(3)-targeted paramagnetic nanoparticles increased MRI signal by 126% in asymmetrically distributed regions primarily in the periphery of the tumor. Similar increases in MR contrast were also observed within the walls of some vessels proximate to the tumor. Despite their relatively large size, nanoparticles penetrated into the leaky tumor neovasculature but did not appreciably migrate into the interstitium, leading to a 56% increase in MR signal at 2 h. Pretargeting of the alpha(nu)beta(3)-integrin with nonparamagnetic nanoparticles competitively blocked the specific binding of alpha(nu)beta(3)-targeted paramagnetic nanoparticles, decreasing the MR signal enhancement (50%) to a level attributable to local extravasation. The MR signal of adjacent hindlimb muscle or contralateral control tissues was unchanged by either the alpha(nu)beta(3)-targeted or control paramagnetic agents. Immunohistochemistry of alpha(nu)beta(3)-integrin corroborated the extent and asymmetric distribution of neovascularity observed by MRI. These studies demonstrate the potential of this targeted molecular imaging agent to detect and characterize (both biochemically and morphologically) early angiogenesis induced by minute solid tumors with a clinical 1.5 Tesla MRI scanner, facilitating the localization of nascent cancers or metastases, as well as providing tools to phenotypically categorize and segment patient populations for therapy and to longitudinally follow the effectiveness of antitumor treatment regimens.

Animals↗

Remodeling of cardiac fiber structure after infarction in rats quantified with diffusion tensor MRI.

Structural remodeling of myocardium after infarction plays a critical role in functional adaptation. Diffusion tensor magnetic resonance imaging (DTMRI) provides a means for rapid and nondestructive characterization of the three-dimensional fiber architecture of cardiac tissues. In this study, microscopic structural changes caused by MI were evaluated in Fischer 344 rats 4 wk after infarct surgery. DTMRI studies were performed on 15 excised, formalin-fixed rat hearts of both infarct (left anterior descending coronary artery occlusion, n = 8) and control (sham, n = 7) rats. Infarct myocardium exhibited increased water diffusivity (41% increase in trace values) and decreased diffusion anisotropy (37% decrease in relative anisotropy index). The reduced diffusion anisotropy correlated negatively with microscopic fiber disarray determined by histological analysis (R = 0.81). Transmural courses of fiber orientation angles in infarct zones were similar to those of normal myocardium. However, regional angular deviation of the diffusion tensor increased significantly in the infarct myocardium and correlated strongly with microscopic fiber disarray (R = 0.86). These results suggest that DTMRI may provide a valuable tool for defining structural remodeling in diseased myocardium at the cellular and tissue level.

Animals↗