PubMed Health⌕ Search

Biomedical subjects

Sandra Bencic-Nagale

Publications and source records attributed to Sandra Bencic-Nagale.

2 recordsLinked to original sources

Microbead chemical switches: an approach to detection of reactive organophosphate chemical warfare agent vapors.

In this article, we describe the preparation and application of microbeads that exhibit a "turn on" fluorescence response within seconds of exposure to diethyl chlorophosphate (DCP) vapor. This sensing approach is modeled after the mechanism for acetylcholinesterase enzyme activity inhibition and uses a specific and irreversible reaction between phosphoryl halides and a fluorescent indicator. The microbeads are fabricated by adsorbing fluoresceinamine (FLA) onto carboxylate-functionalized polymer microbeads coated with poly(2-vinylpyridine) (PVP). When the microbeads are subjected to DCP vapor, the conversion of FLA into a phosphoramide causes a rapid and intense fluorescence increase. The PVP layer provides a high density of proton-accepting pyridine nitrogen sites that neutralize the HCl released during the reaction, thereby maintaining high product fluorescence, even after vapor exposure. No significant response is observed when the microbeads are subjected to other nerve agent simulants, a mustard gas simulant, and volatile organics. The size, sensitivity, and subsecond response of these microbeads make them suitable for nerve agent vapor detection and inclusion into microbead sensor arrays.

Journal Article↗

Extending the longevity of fluorescence-based sensor arrays using adaptive exposure.

Fluorescent microbead sensor arrays were prepared to determine sensor array longevity. Sensor longevity is limited by photobleaching of the dyes attached to the microbeads and presents one of the biggest drawbacks of most fluorescent dye-based arrays. Responses of an array of organic vapor sensors were acquired for 2 weeks to evaluate the sensor performance over time. Photobleaching effects were overcome in two ways: (1) by limiting the excitation light power and gradually increasing the power at a rate comparable to the sensor photobleaching rates and (2) by illuminating subsections of the array through an optical slit. Both approaches extended the longevity of a sensor array. During the longevity study, the sensor arrays were employed to test their ability to correctly distinguish between responses to seven vapors. A high classification accuracy (99.8%) was obtained after 17,700 exposures for vapor responses collected over two weeks using only approximately 8% of the array's surface area.

Journal Article↗