PubMed Health⌕ Search

Biomedical subjects

Sandra Furlanetto

Publications and source records attributed to Sandra Furlanetto.

12 recordsLinked to original sources

Development of a CZE method for the determination of mizolastine and its impurities in pharmaceutical preparations using response surface methodology.

A fast and selective CZE method for the determination of mizolastine and related impurities is described. Response surface methodology was applied to study the influence of phosphate/triethanolamine (TEA) buffer concentration, heptakis(2,3,6-tri-O-methyl)-beta-CD (TMbetaCD) concentration, voltage and temperature. The optimum conditions were: 105 mM phosphate/TEA buffer (pH 3.0) containing 10 mM TMbetaCD, temperature 19 degrees C and voltage 30 kV. Validation of the method was performed in drug substance and drug product. Robustness was evaluated using a Plackett-Burman design, including pH among the considered factors. Applying the optimal conditions, the nine peaks were baseline separated in about 10 min. The method was applied to the quality control of mizolastine in controlled-release tablets.

Benzimidazoles↗

Selection of background electrolyte for CZE analysis by a chemometric approach. Part II. Separation of a mixture of basic beta-blocker drugs.

In the first part of this study a chemometric approach to choose a suitable background electrolyte for CZE analysis was introduced. Two hundred and twenty-two possible electrolytes were previously characterized by means of the descriptors pH, conductivity, ionic strength and relative viscosity and the approach was applied to the separation of a mixture of acidic drugs. In this second part, another application concerning the analysis of basic drugs is presented. The test mixture was made of eight beta-blocker drugs. According to the basic nature of the analytes, the original data set was reduced to a new subset of 117 objects with pH less than or equal to 7, and after computing principal components the new set of objects was represented in a two-dimensional space. Ten objects to be tested in CZE, capable of covering homogeneously the principal component space, were selected by means of Kennard-Stone algorithm. The data set was further reduced around the BGEs which gave the best results, and a new set of electrolytes to be tested was selected. Using pH 4 citrate buffer, an electropherogram with baseline resolution was obtained in 10 min. A Doehlert design was run to further reduce analysis time, and applying the optimized conditions (voltage, 23 kV; temperature, 26 degrees C) the separation was obtained in about 7 min.

Adrenergic beta-Antagonists↗

Selection of background electrolyte for CZE analysis by a chemometric approach. Part I. Separation of a mixture of acidic non-steroidal anti-inflammatory drugs.

This paper is the first part of the presentation of a chemometric approach for the rapid selection of a suitable background electrolyte (BGE) in CZE analysis of small drug molecules. The strategy is based on principal component analysis and experimental design. In this first section, the approach is applied to the analysis of a mixture of six arylpropionic anti-inflammatory drugs. Initially, 222 possible aqueous background electrolytes (objects) were characterized using as descriptors pH, conductivity, ionic strength and relative viscosity. In order to allow the dissociation of the acidic analytes, this original data set was reduced to 154 background electrolytes with pH values higher than or equal to 5. Principal component analysis made it possible to graphically represent the new set of objects, described by the four variables, in a two-dimensional space. Among these electrolytes, Kennard-Stone algorithm selected ten objects to be tested by CZE, covering homogeneously principal component space. CZE analyses were carried out with the selected electrolytes, and 0.1 M borax was identified as the most suitable one for the specified application. Finally, the characteristics of the analysis were finely tuned by means of a response surface study, which allowed the best conditions to be determined: borax concentration, 0.09 M; methanol, 6% (v/v); temperature, 24 degrees C, voltage, 20 kV. Applying these conditions, a baseline resolution among the six compounds was obtained in less than 10 min.

Anti-Inflammatory Agents, Non-Steroidal↗

Mixture design in the optimization of a microemulsion system for the electrokinetic chromatographic determination of ketorolac and its impurities: method development and validation.

Microemulsion EKC (MEEKC) was used for the determination of ketorolac and its three impurities. The microemulsion system was optimized, for the first time in the literature, using a multivariate strategy involving a mixture design. A 13-run experimental plan covering an experimental domain defined by the components aqueous phase (10 mM borate buffer pH 9.2), oil phase (n-heptane) and surfactant/cosurfactant (SDS/n-butanol) was carried out. Good results were obtained with all microemulsions tested considering as responses analysis time and resolution, and according to the desirability function the best microemulsion system was constituted by 90.0% 10 mM borate buffer, 2.0% n-heptane, 8.0% of SDS/n-butanol in 1:2 ratio. Finally, with the aim of reducing analysis time, a response surface study was carried out in the experimental domain defined by the process variables temperature and voltage and the best values were 17 degrees C and -17 kV, respectively. Applying the optimised conditions, a complete resolution among the analytes was obtained in about 3 min using the short-end injection method. The method was validated for both drug substances and drug product and was applied to the quality control of ketorolac in coated tablets. A comparison of MEEKC, MEKC and CEC for assaying ketorolac and its related substances has been made.

Anti-Inflammatory Agents, Non-Steroidal↗

Penicillin G acylase as chiral selector in CE using a pullulan-coated capillary.

In the present study, penicillin G acylase (PGA), an enzyme belonging to the family of hydrolases, has been investigated as chiral selector in CE using the partial filling technique. Owing to the strong disposition of PGA to be adsorbed by the inner capillary wall, permanently coated capillaries were used to diminish both the protein-wall interactions and the EOF. In particular, the silica surface of the capillary was chemically coated by an antiadhesive and an hydrophilic layer of pullulan, a high-molecular-mass homopolysaccharide. The coating procedure consisted in the silanization with glycidoxypropyltrimethoxysilane and the subsequent coupling of the hydroxyl groups of pullulan onto the silanized capillary. Using this approach, a significant EOF suppression was obtained within a wide pH range (pH 3.0-9.0); this result was very important in order to find the suitable conditions for the application of partial filling technique. The optimization of partial filling was carried out by considering the effects of different experimental conditions (buffer pH, PGA concentration, and loading duration), on the migration time and enantioresolution of rac-ketoprofen. Under the selected conditions as: 100 mM sodium phosphate buffer (pH 5.5) containing 240 microM of PGA (partial filling of 120 s at a pressure of 50 mbar), a series of acidic compounds resulted to be enantioresolved in about 10 min. The long-term stability of the proposed coating was evaluated; more than 100 injections were performed without significant loss of reproducibility.

Buffers↗

Development and evaluation of an in vitro method for prediction of human drug absorption I. Assessment of artificial membrane composition.

A study was undertaken aimed at developing a dynamic in vitro method based on the use of artificial membranes for screening and prediction of the absorption properties of drugs. The development of a suitable artificial membrane simulating the behaviour of the natural gastrointestinal one is the critical step for the fulfillment of this research and it has been the aim of the present work. A series of filters of different chemical nature and different characteristics (pore size, percent of porosity, thickness) were evaluated and compared in order to select the most suitable one to use as support for the artificial lipid membrane preparation. Permeation experiments were performed by using naproxen as reference model drug. The target was to achieve a naproxen apparent permeability (P(app)) value close to that previously obtained using a Caco-2 cell dynamic methodology (4.88 x 10(-5)cms(-1)), which related well to the fraction of dose absorbed in vivo in human. Filters of cellulose nitrate-acetate mixture with a porosity of 70% and 0.025 microm pore size were selected on the basis of the highest reproducibility of results and suitable drug P(app) value obtained. Mixture design experiments were then carried out in order to optimize the composition of the lipid mixture to use for porous support impregnation to obtain the desired P(app) value. Sixteen different lipid mixtures were prepared according to mixture experimental plan and evaluated by diffusion experiments. The contour plot obtained was used to select an optimum lipidic mixture (cholesterol 2.10%; Lipoid((R)) E 80 1.70%; n-octanol 96.2%) for the cellulose nitrate-acetate membrane impregnation. The experimental response obtained from diffusion experiments performed by utilising the optimised lipidic impregnation mixture, was 4.88 x 10(-5)cms(-1), matching exactly the prefixed target.

Anti-Inflammatory Agents, Non-Steroidal↗

Analysis of catechins in Theobroma cacao beans by cyclodextrin-modified micellar electrokinetic chromatography.

A micellar electrokinetic chromatography (MEKC) method was developed for the quantitation of polyphenols (+)-catechin and (-)-epicatechin (catechin monomers) and the methylxanthine theobromine in Theobroma cacao beans. Owing to the poor stability of catechin monomers in alkaline conditions, a 50 mM Britton-Robinson buffer at a pH 2.50 was preferred as the background electrolyte. Under these conditions, the addition of hydroxypropyl-beta-cyclodextrin (HP-beta-CD) at a concentration of 12 mM to the SDS micellar solution (90 mM), resulted in a cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) endowed with two peculiar advantages compare to the conventional MEKC: (i) strong improvement of separation of the most important phytomarkers of T. cacao and (ii) enantioselectivity toward (+/-)-catechin. In particular, separation of methylxanthines (theobromine and caffeine), procyanidin dimers B1 and B2, and catechins (epicatechin and catechin) was obtained simultaneously to the enantioseparation of racemic catechin within 10min. The enantioselectivity of the method makes it suitable in evaluation of possible epimerisation at the C-2 position of epicatechin monomer potentially occurring during heat processing and storage of T. cacao beans. The extraction procedure of the phytomarkers from the beans was approached using ultrasonic bath under mild conditions optimized by a multivariate strategy. The method was validated for robustness, selectivity, sensitivity, linearity, range, accuracy and precision and it was applied to T. cacao beans from different countries; interestingly, the native enantiomer (+)-catechin was found in the beans whereas, for the first time we reported that in chocolate, predominantly (-)-catechin is present, probably yielded by epimerisation of (-)-epicatechin occurred during the manufacture of chocolate.

Cacao↗

Study of formulation variables influencing the drug release rate from matrix tablets by experimental design.

Experimental design was utilized to simultaneously investigate the effect of varying the type of diluent (insoluble Calcium phosphate or water-soluble arabic gum) and the diluent/matrix ratio on the drug release behaviour from both lipophilic (glyceryl behenate, Compritol) or hydrophilic (hydroxypropylmethylcellulose) matrix tablets. Ketoprofen, theophylline and sodium sulphadiazine were selected as model drugs on the basis of their respectively very low, medium and high water-solubility, in order to evaluate the influence of this parameter as well. The selected response variables were the dissolution efficiency (i.e. the area under the dissolution curve) after one and six hours and the time necessary to dissolve 10% drug. Tablets obtained by direct compression of drug-diluent-matrix ternary mixtures prepared according to the experimental plan provided for by an asymmetric screening matrix, were tested for drug release properties using a USP paddle apparatus. Graphic analysis of the effects allowed identification, for each examined drug, of the formulation factors active on the selected responses and determination of the proper level of the variables to be selected for the response improvement. The different results obtained with the three examined drugs pointed out the role of the drug solubility in determining the influence of formulation parameters on drug release rate from matrix tablets.

Calcium Phosphates↗

Analysis of ketorolac and its related impurities by capillary electrochromatography.

Capillary electrochromatography (CEC) was employed for the assay of ketorolac (KT) and its known related impurities [1-hydroxy analog of ketorolac (HK), 1-keto analog of ketorolac (KK), ketorolac decarboxylated (DK)] in both drug substance and coated tablets. Detection was made at 323 nm and flufenamic acid was selected as internal standard. The experiments were performed in a 100 microm i.d. capillary packed with RP-18 silica particles (33.0, 24.5, 23.0 cm total, effective and packed lengths, respectively). The composition of the mobile phase was optimised by changing pH of the buffer and acetonitrile (ACN) content and by addition of other organic modifiers (methanol, ethanol, isopropanol, n-propanol) in order to evaluate the effect of these factors on the method performance (efficiency, retention and resolution). The optimum mobile phase consisted of a mixture of 50 mM ammonium formate buffer pH 3.5-water-acetonitrile (10:20:70, v/v/v), while voltage and temperature were set at 30 kV and 20 degrees C, respectively. Applying these conditions, all peaks were baseline resolved and the analysis was performed in less than 9 min. Selectivity, repeatability of retention time and peak area, detection and quantitation limits, linearity and range, precision and accuracy were also investigated. R.S.D. and bias values obtained for all the analytes were below 5% and sensitivity was satisfactory, thus the method was deemed suitable for pharmaceutical quality control. Applying the method to coated tablets, a recovery of 98.5+/-0.8% and an R.S.D. of 0.5% were found.

Calibration↗

Simultaneous liquid chromatographic analysis of catecholamines and 4-hydroxy-3-methoxyphenylethylene glycol in human plasma. Comparison of amperometric and coulometric detection.

The comparison of two HPLC methods, one with electrochemical detection and the other with coulometric detection, for the simultaneous analysis of catecholamines and 4-hydroxy-3-methoxyphenylethylene glycol (MHPG) in human plasma is presented. The careful pre-treatment of plasma samples is based on an innovative two-step procedure by means of solid-phase extraction (SPE) which uses one single hydrophilic-lipophilic balance cartridge. The extraction yield values found were higher than 85% for epinephrine, norepinephrine and MHPG, and higher than 70% for dopamine. The assays carried out on real plasma samples with the coulometric system gave good results in terms of sensitivity (limits of quantitation: 0.10-0.15 ng ml(-1) for catecholamines, 0.6 ng ml(-1) for MHPG) and selectivity, while interference was sometimes found when using the amperometric system. Precision was also satisfactory, with relative standard deviation values for intermediate precision always lower than 6%. The HPLC method with coulometric detection coupled to a novel SPE procedure is thus suitable for the simultaneous determination of catecholamines and MHPG in plasma of volunteers subjected to experimental stress.

Case-Control Studies↗

Quality control of commercial tablets containing the novel antipsychotic quetiapine.

Quetiapine (bis [2-(2-[4-(dibenzo[b,f][1,4]thiazepin-11-yl]ethoxy)ethanol]fumarate) is the most recent agent introduced on the drug market for the treatment of psychotic disorders. Two different analytical methods for the quality control of quetiapine in commercial formulations have been developed and compared: a spectrophotometric method and a capillary zone electrophoretic (CZE) method. The spectrophotometric assay was carried out measuring the absorbance at a wavelength of 246 nm. The CZE method used an uncoated fused-silica capillary and a pH 2.5, 50 mM phosphate buffer as the background electrolyte. The detection wavelength was 205 nm, the separation voltage was 15 kV, and a complete electrophoretic run lasts less than 2.5 min. Extraction of quetiapine from the commercial tablets consisted of a simple one-step treatment with a pH 2.5, 50 mM phosphate buffer. Linearity was observed in the 5-25 microg ml(-1) concentration range of quetiapine for the spectrophotometric method, and in the 5-50 microg ml(-1) concentration range for the electrophoretic method. Both methods gave satisfactory results in terms of repeatability and intermediate precision (RSD<1.9%). Also accuracy values were very good for both methods, the recovery being between 98.2 and 100.5%.

Antipsychotic Agents↗

Didanosine extended-release matrix tablets: optimization of formulation variables using statistical experimental design.

Statistical experimental design was applied to evaluate the influence of some process and formulation variables and possible interactions among such variables, on didanosine release from directly-compressed matrix tablets based on blends of two insoluble polymers, Eudragit RS-PM and Ethocel 100, with the final goal of drug release behavior optimization. The considered responses were the percent of drug released at three determined times, the dissolution efficiency at 6 h and the time to dissolve 10% of drug. Four independent variables were considered: tablet compression force, ratio between the polymers and their particle size, and drug content. The preliminary screening step, carried out by means of a 12-run asymmetric screening matrix according to a D-optimal design strategy, allowed evaluation of the effects of different levels of each variable. The drug content and the polymers ratio had the most important effect on drug release, which, moreover, was favored by greater polymers particle size; on the contrary the compression force did not have a significant effect. The Doehlert design was then applied for a response-surface study, in order to study in depth the effects of the most important variables. The desirability function was used to simultaneously optimize the five considered responses, each having a different target. This procedure allowed selection, in the studied experimental domain, of the best formulation conditions to optimize drug release rate. The experimental values obtained from the optimized formulation highly agreed with the predicted values. The results demonstrated the reliability of the model in the preparation of extended-release matrix tablets with predictable drug release profiles.

Anti-HIV Agents↗