PubMed Health⌕ Search

Biomedical subjects

Sandra S Halliburton

Publications and source records attributed to Sandra S Halliburton.

16 recordsLinked to original sources

Noninvasive quantification of fluid mechanical energy losses in the total cavopulmonary connection with magnetic resonance phase velocity mapping.

A major determinant of the success of surgical vascular modifications, such as the total cavopulmonary connection (TCPC), is the energetic efficiency that is assessed by calculating the mechanical energy loss of blood flow through the new connection. Currently, however, to determine the energy loss, invasive pressure measurements are necessary. Therefore, this study evaluated the feasibility of the viscous dissipation (VD) method, which has the potential to provide the energy loss without the need for invasive pressure measurements. Two experimental phantoms, a U-shaped tube and a glass TCPC, were scanned in a magnetic resonance (MR) imaging scanner and the images were used to construct computational models of both geometries. MR phase velocity mapping (PVM) acquisitions of all three spatial components of the fluid velocity were made in both phantoms and the VD was calculated. VD results from MR PVM experiments were compared with VD results from computational fluid dynamics (CFD) simulations on the image-based computational models. The results showed an overall agreement between MR PVM and CFD. There was a similar ascending tendency in the VD values as the image spatial resolution increased. The most accurate computations of the energy loss were achieved for a CFD grid density that was too high for MR to achieve under current MR system capabilities (in-plane pixel size of less than 0.4 mm). Nevertheless, the agreement between the MR PVM and the CFD VD results under the same resolution settings suggests that the VD method implemented with a clinical imaging modality such as MR has good potential to quantify the energy loss in vascular geometries such as the TCPC.

Biomechanical Phenomena↗

Coronary artery imaging with multidetector computed tomography: a call for an evidence-based, multidisciplinary approach.

Modern multidetector computed tomography systems are capable of a comprehensive assessment of the cardiovascular system, including noninvasive assessment of coronary anatomy. Multidetector computed tomography is expected to advance the role of noninvasive imaging for coronary artery disease, but clinical experience is still limited. Clinical guidelines are necessary to standardize scanner technology and appropriate clinical applications for coronary computed tomographic angiography. Further evaluation of this evolving technology will benefit from cooperation between different medical specialties, imaging scientists, and manufacturers of multidetector computed tomography systems, supporting multidisciplinary teams focused on the diagnosis and treatment of early and advanced stages of coronary artery disease. This cooperation will provide the necessary education, training, and guidelines for physicians and technologists assuring standard of care for their patients.

Coronary Angiography↗

Contrast enhancement of coronary atherosclerotic plaque: a high-resolution, multidetector-row computed tomography study of pressure-perfused, human ex-vivo coronary arteries.

OBJECTIVES: The objective of this study was to investigate the effect of contrast injection on atherosclerotic coronary plaque attenuation measured using multidetector-row computed tomography. BACKGROUND: Recent multidetector-row computed tomography studies have described the characterization of coronary atherosclerotic plaque on the basis of Hounsfield unit values. The influence of contrast injection on the attenuation of individual plaque components, however, is unknown. METHODS: Using a pressurized perfusion system, 10 human coronary arteries were examined postmortem with multidetector-row computed tomography and histology. Pre-enhanced, peak-enhanced, and delayed enhanced multidetector-row computed tomography images were acquired during continuous perfusion of the vessel. A total of 37 focal atherosclerotic plaques were identified. Vessel wall attenuation was measured from multidetector-row computed tomography images during all three enhancement phases. On the basis of the histology, plaques were categorized as noncalcified (predominantly fibrous or predominantly fibrofatty), mixed calcified (calcified fibrous or calcified necrotic core), or densely calcified. The mean Hounsfield unit was compared among contrast phases for all plaques and in plaque subgroups. RESULTS: We observed contrast enhancement of atherosclerotic plaques within the vessel wall. For noncalcified plaques including both fibrous and fibrofatty plaques, the mean Hounsfield unit of the vessel wall during and after contrast injection exceeded the mean value before injection (t-test, P<0.002). CONCLUSION: The present study demonstrates that intra-arterial injection of iodinated contrast agent results not only in luminal enhancement but also in atherosclerotic plaque enhancement in pressure-perfused coronary arteries imaged ex vivo. Plaque enhancement should be considered when characterizing plaque components on the basis of Hounsfield unit with multidetector-row computed tomography.

Adult↗

Coregistered MR imaging myocardial viability maps and multi-detector row CT coronary angiography displays for surgical revascularization planning: initial experience.

PURPOSE: To evaluate assignment of left ventricular (LV) myocardial segments to coronary arterial territories by using coregistered magnetic resonance (MR) imaging and multi-detector row computed tomography (CT) displays; to assess the accuracy of coregistered displays in determining the distribution of clinically important coronary artery disease (CAD) and regional effect of CAD on LV myocardium in patients with chronic ischemic heart disease (CIHD); and to determine the utility of coregistered displays in optimizing surgical revascularization planning. MATERIALS AND METHODS: This study was HIPAA compliant and was approved by the local Institutional Review Board, with waiver of informed consent. Twenty-six patients (19 men, seven women; age, 56 years +/- 12 [+/- standard deviation]) with CIHD underwent MR imaging assessment of myocardial viability and multi-detector row CT assessment of CAD on the same day. For coregistration, a population-based LV model was fit to each data set separately; models were then registered spatially. For data analysis, correspondence between coregistered displays and the 17-segment LV model for assessment of CIHD was evaluated, accuracy of using coregistered displays to evaluate the extent of CAD and myocardial disease was assessed, and utility of coregistered displays in optimizing surgical revascularization planning was determined. RESULTS: Coronary assignment for coregistered displays and the 17-segment LV model differed in 17% of myocardial segments. For the majority of patients, three segments (midanterolateral [62%], apical lateral [73%], and apical inferior [58%]) were discordant. Segments were supplied by the left anterior descending artery, a diagonal branch, or a ramus intermedius with diagonal distribution in all but one case. Coregistered displays were deemed concordant with selective coronary angiography and alternate myocardial imaging in all cases. Overall, surgical planning was potentially enhanced in 83% of cases because, compared with alternate imaging modalities, coregistered displays were believed to demonstrate the relationship between coronary arteries and underlying myocardial tissue more definitively and efficiently (for patients in whom surgery was performed) or more correctly and comprehensively (for a presumably better-tailored surgery). CONCLUSION: Assessment of CIHD can be improved by using coregistered displays that directly relate the condition of LV myocardium to the anatomy of the coronary arteries in individual patients.

Contrast Media↗

Potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT.

OBJECTIVE: The potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT was evaluated using Agatston, volume, and mass scoring algorithms. SUBJECTS AND METHODS: Fifty-six patients were imaged twice using an identical prospectively ECG-triggered sequential scanning protocol. The Agatston, volume, and mass scores were computed by two observers independently. In addition, a patient's total Agatston score was referenced to an age- and sex-stratified database to determine a percentile ranking. Interscan, interobserver, and intraobserver variability and the resultant impact on patients' risk stratifications were assessed. RESULTS: Significant interscan differences were found for all mean coronary calcium scores (Wilcoxson's signed rank test, p <0.0001). Although the median percentage of interscan variability was low for all scoring methods, the interquartile range was wide, indicating significant variability in the data. Median scores (lower quartile-upper quartile) for observers 1 and 2, respectively, were as follows: Agatston, 5% (0-79%) and 6% (0-83%); volume, 12% (0-51%) and 12% (0-57%); and mass, 14% (0-57%) and 14% (0-58%). Interobserver and intraobserver differences between mean calcium scores were not significant, and consequently, lower interobserver and intraobserver variabilities (narrow interquartile ranges of 0-5%) were observed for all scores. Despite significant interscan differences in calcium scores, the percentile ranking assigned to the two scans differed in only 13% of patients. Interobserver differences resulted in a change in the percentile ranking in 7-9% of patients, whereas intraobserver differences caused a change in only 5% of patients. CONCLUSION: The accuracy of sequential MDCT for coronary calcium quantification is sufficient in most cases for stratification of patient risk.

Adult↗

CT of the heart: principles, advances, clinical uses.

Computed tomography (CT) has become a standard test for many cardiovascular conditions (eg, aortic dissection and pulmonary embolism), and it has great potential in assessing other common diseases, including coronary artery disease. We review the principles of CT and its uses in cardiovascular medicine.

Cardiology↗

Fast measurements of flow through mitral regurgitant orifices with magnetic resonance phase velocity mapping.

Magnetic-resonance (MR) phase velocity mapping (PVM) shows promise in measuring the mitral regurgitant volume. However, in its conventional nonsegmented form, MR-PVM is slow and impractical for clinical use. The aim of this study was to evaluate the accuracy of rapid, segmented k-space MR-PVM in quantifying the mitral regurgitant flow through a control volume (CV) method. Two segmented MR-PVM schemes, one with seven (seg-7) and one with nine (seg-9) lines per segment, were evaluated in acrylic regurgitant mitral valve models under steady and pulsatile flow. A nonsegmented (nonseg) MR-PVM acquisition was also performed for reference. The segmented acquisitions were considerably faster (<10 min) than the nonsegmented (>45 min). The regurgitant flow rates and volumes measured with segmented MR-PVM agreed closely with those measured with nonsegmented MR-PVM (differences <5%, p > 0.05), when the CV was large enough to exclude the region of flow acceleration and aliasing from its boundaries. The regurgitant orifice shape (circular vs. slit-like) and the presence of aortic outflow did not significantly affect the accuracy of the results under both steady and pulsatile flow (p > 0.05). This study shows that segmented k-space MR-PVM can accurately quantify the flow through regurgitant orifices using the CV method and demonstrates great clinical potential.

Animals↗

Noninvasive imaging of coronary arteries: current and future role of multi-detector row CT.

While invasive imaging techniques, especially selective conventional coronary angiography, will remain vital to planning and guiding catheter-based and surgical treatment of significantly stenotic coronary lesions, the comprehensive and serial assessment of asymptomatic or minimally symptomatic stages of coronary artery disease (CAD) for preventive purposes will eventually need to rely on noninvasive imaging techniques. Cardiovascular imaging with tomographic modalities, including computed tomography (CT) and magnetic resonance imaging, has great potential for providing valuable information. This review article will describe the current and future role of cardiac CT, and in particular that of multi-detector row CT, for imaging of atherosclerotic and other pathologic changes of the coronary arteries. It will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development.

Coronary Angiography↗

Clinical blood flow quantification with segmented k-space magnetic resonance phase velocity mapping.

PURPOSE: To evaluate the accuracy of segmented k-space magnetic resonance phase velocity mapping (PVM) in quantifying aortic blood flow from through-plane velocity measurements. MATERIALS AND METHODS: Two segmented PVM schemes were evaluated, one with seven lines per segment (seg-7) and one with nine lines per segment (seg-9), in twenty patients with cardiovascular disease. A non-segmented (non-seg) PVM acquisition was also performed to provide the reference data. RESULTS: There was agreement between the aortic flow curves acquired with segmented and non-segmented PVM. The calculated systolic and total flow volume per cycle from the seg-7 and the seg-9 scans correlated and agreed with the flow volumes from the non-seg scans (differences < 5%). Sign tests showed that there were no statistically significant differences (P-values > 0.05) between the segmented and the non-segmented PVM measurements [corrected]. Seg-9, which was the fastest among the three sequences, provided adequate spatial and temporal resolution (> 10 phases per cycle). CONCLUSION: Segmented k-space PVM shows great clinical potential in blood flow quantification.

Aged↗

Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality?

PURPOSE: To evaluate segmented reconstruction algorithms for spiral multi-slice computed tomography (MSCT) that use data from two cardiac cycles to improve temporal resolution (tau) for imaging of the heart. MATERIALS AND METHODS: An initial group of 78 cardiac patients (heart rates [HR] = 63-167 beats per minute [bpm]) were imaged on a 4-slice, 500 ms gantry rotation time scanner (scanner 1). Images were reconstructed with a single-segment algorithm using data from one cardiac cycle with a reconstruction window of fixed length (tau = 250 ms). Images were also reconstructed with two variants of a multi-segment algorithm using data from two cardiac cycles where only one end of the reconstruction window was fixed and the other end was freely moveable to allow adjustment of tau according to HR: (1) "2-segment fixed start" with fixed start of reconstruction, (2) "2-segment fixed end" with fixed end of reconstruction (for both, tau = 125-250 ms). The resulting image sets were ranked from best to worst (1-3, respectively) in a side-by-side, blinded comparison by two independent readers. A second group of 26 patients (HR = 74-90 bpm) were imaged on a 12-slice, 420 ms gantry rotation time scanner (scanner 2). Data were reconstructed with a single-segment algorithm (tau = 210 ms) and a "2-segment fixed start" algorithm (tau = 105-210 ms) and image sets were ranked from best to worst (1-2, respectively). RESULTS: There was no clear evidence that any one technique is superior for imaging on scanner 1. Reader 1 ranked single-segment images the highest for all HRs, but statistically significant differences among the three algorithms were only found for the lowest HRs (< 80 bpm), where reader 1 preferred single-segment over "2-segment fixed end" techniques (p = 0.048). The highest rankings given by reader 2 varied according to HR: single-segment images were superior for lowest HRs, while "2-segment fixed start" images were superior for HRs > 80 bpm; none of these comparisons reached statistical significance. Improved performance of 2-segment reconstruction was found with scanner 2. Both readers ranked "2-segment fixed start" images the highest (p < 0.01). CONCLUSIONS: The added value of 2-segment cardiac reconstruction algorithms for spiral MSCT was not demonstrated for a 4-slice, 500 ms gantry rotation time scanner but shown to be beneficial for a 12-slice, 420 ms gantry rotation time scanner in the crucial HR range of 74-90 bpm.

Adolescent↗

Performance evaluation of a multi-slice CT system with 16-slice detector and increased gantry rotation speed for isotropic submillimeter imaging of the heart.

BACKGROUND: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany). MATERIALS AND METHODS: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented. ECG-gated scan and image reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose are described, key parameters for image quality and simulation results presented, and phantom studies and initial patient experience discussed. The impact of reduced gantry rotation time (0.42 s) on temporal resolution and initial estimations of the patient dose are presented. RESULTS: Extensions of ECG-gated reconstruction algorithms used for 4-slice CT provide adequate image quality for up to 16 slices. For each detector collimation different slice widths are available for retrospective reconstruction with well-defined slice sensitivity profiles (SSPs). For coronary CTA the heart can be covered with 0.75 mm collimation within a 20-s breathhold. The best possible spatial resolution is 0.5 x 0.5 x 0.6 mm. For 0.42 s gantry rotation time, temporal resolution reaches its optimum (105 ms) at a heart rate of 81 bpm. Effective patient dose for coronary CTA is 4-5 mSv using ECG-pulsed acquisition. CONCLUSION: The clinical performance of coronary CTA by means of spatial resolution, temporal resolution and scan time is substantially improved with the evaluated 16-slice CT scanner. Also, display of smaller coronary segments and instent visualization are substantially improved.

Algorithms↗

Automated three-dimensional assessment of coronary artery anatomy with intravascular ultrasound scanning.

BACKGROUND: Angiography allows the definition of advanced, severe stages of coronary artery disease, but early atherosclerotic lesions, which do not lead to luminal stenosis, are not identified reliably. In contrast, intravascular ultrasound scanning allows the precise characterization and quantification of a wide range of atherosclerotic lesions, independent of the severity of luminal stenosis. METHODS: Three-dimensional (3-D) reconstruction of entire coronary segments is possible with the integration of sequential 2-dimensional tomographic images and allows volumetric analysis of coronary arteries. RESULTS: Automated systems able to recognize lumen and vessel borders and to display 3-D images are becoming available. CONCLUSION: These systems have the potential for on-line 3-D image reconstruction for clinical decision-making and fast routine volumetric analysis in research studies. This review describes 3-D intravascular ultrasound scanning acquisition, analysis, and processing, and the associated technical challenges.

Coronary Artery Disease↗

Evaluation of left ventricular dysfunction using multiphasic reconstructions of coronary multi-slice computed tomography data in patients with chronic ischemic heart disease: validation against cine magnetic resonance imaging.

PURPOSE: Multi-slice computed tomography (MSCT) is an emerging technique for the angiographic assessment of coronary artery disease (CAD). The purpose of this work was to determine if multiphasic reconstructions of the same data used for the assessment of CAD could also be used for global functional evaluation of the left ventricle (LV). MATERIALS AND METHODS: Fifteen patients with chronic ischemic heart disease (CIHD) were imaged for CAD using a contrast-enhanced retrospective electrocardiographic-gated spiral technique on a MSCT scanner. The same data were reconstructed at both end-diastole and end-systole in order to measure left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV), and ejection fraction (LVEF). The results were compared to values obtained using a cine true-fast imaging with steady-state precession technique on a magnetic resonance imaging (MRI) scanner. Interobserver variability in the measurement from MSCT images was also evaluated. RESULTS: For LVEF, there was substantial agreement between MSCT and MRI (intraclass correlation coefficient of 0.825); the intermodality reproducibility for LVEF (5%) was within an acceptable clinical range. However, mean values of LVEDV and LVESV with MSCT compared to cine MRI (LVEDV: 262.0 +/- 85.6 ml and 297.2 +/- 98.8 ml, LVESV: 196.2 +/- 75.6 ml and 218.6 +/- 90.99 ml, respectively) were significantly less for both volumes (p < 0.015). Intermodality variabilities for these measurements were high (15 and 13% for LVEDV and LVESV, respectively). Readers' mean measurements of LVESV from MSCT images were significantly different (p = 0.003) resulting in differences in calculation of LVEF (p < 0.024). Still, interobserver variabilities for all values were acceptable (6, 8, and 5% for LVEDV, LVESV, and LVEF, respectively). CONCLUSION: Although values for LVEDV and LVESV were less with MSCT than with MRI, LVEF values were in agreement. This suggests that combined imaging of CAD and the evaluation of global LV dysfunction due to CIHD is feasible with the same MSCT acquisition.

Adult↗

Non-invasive assessment of plaque morphology and remodeling in mildly stenotic coronary segments: comparison of 16-slice computed tomography and intravascular ultrasound.

BACKGROUND: Non-invasive identification and characterization of mildly stenotic atherosclerotic lesions is an increasingly important focus of coronary imaging. DESIGN: We examined the accuracy of multi (16)-slice computed tomography (MSCT) for imaging of these lesions in comparison with intravascular ultrasound (IVUS). MATERIALS: Mildly stenotic segments of the left coronary artery were identified by coronary angiography and analyzed using IVUS and contrast-enhanced MSCT. Independent reviewers evaluated the accuracy of MSCT for presence, composition and distribution of atherosclerotic plaque and remodeling response in comparison to IVUS using receiver operating characteristic (ROC) data analysis. RESULTS: Of 46 segments in 14 patients, diagnostic characterization by MSCT was possible in 37 (80.4%) segments. In these segments the accuracy of MSCT for identifying plaque presence, calcification, distribution and positive remodeling was consistently greater than 0.90 (reader 1) and 0.87 (reader 2). CONCLUSION: State-of-the-art MSCT can accurately identify mildly stenotic coronary atherosclerosis and provide an assessment of morphology and remodeling response.

Adult↗

Pilot study of coronary atherosclerotic risk and plaque burden in HIV patients: 'a call for cardiovascular prevention'.

BACKGROUND: Highly active antiretroviral therapy (HAART) has dramatically improved the life expectancy of patients with human immunodeficiency virus (HIV) prompting increasing concerns related to chronic management. Suggestions of greater cardiovascular risk, partially related to recently proposed HAART-induced dyslipidemia and glucose intolerance, amplify these concerns. At this time, further corroboration of the emerging evidence for increased coronary risk, as well as complimentary estimates of coronary artery atherosclerotic burden, would be valuable to practicing physicians. METHODS: Seventeen HIV patients on HAART (all from the same HIV clinic population) without coronary artery disease (CAD) were referred to Preventive Cardiology for treatment of dyslipidemia ('referred group'). Upon entry, they underwent computed tomography (CT) of the coronary arteries. Subsequently, the referred group was matched (1:4) for age, gender and traditional risk to non-HIV non-CAD subjects (matched group, n=68) from the University of Illinois CT database. A serial review of 90 subjects from the original HIV population was sampled to determine general cardiovascular risk. RESULTS: Thirteen (76%) of the 17 referred patients revealed the presence of coronary calcium compared with 63% in the matched HIV seronegative controls (P=0.18). Log-transformed median calcium score was 2.93+/-2.3 in the referred group versus 1.97+/-2.5 in the matched group (P=0.09). Fifty one percent of the overall population smoked cigarettes, 11% were diabetic (30% diagnosed pre-HAART and 70% post-HAART) and 30% were hypertensive (33% diagnosed pre-HAART and 67% post-HAART). CONCLUSIONS: In a particularly dyslipidemic subgroup of HIV subjects without known CAD we found evidence for atherosclerosis in three-quarters based on coronary calcium. Further, in this population of HIV patients on HAART, we found an enhanced prevalence of traditional cardiovascular risk. This pilot study encourages the development of preventive strategies in this population.

Adult↗