Publications and source records attributed to Sanford L Meeks.

At least 19 recordsLinked to original sources

Daily variations in the position of the prostate bed in patients with prostate cancer receiving postoperative external beam radiation therapy.

PURPOSE: The aim of this study was to evaluate the extent of the variation in the position of the prostate bed with respect to the bony anatomy. METHODS AND MATERIALS: Four patients were treated to 70 Gy in 35 fractions. Before each fraction, a megavoltage computed tomography (CT) of the prostate bed was obtained, resulting in a total of 140 CT studies. Retrospectively, each CT scan was aligned to the simulation kilovoltage scan based on bony anatomy and the prostate bed. The difference between the 2 alignments was calculated for each scan. RESULTS: The average differences (+/-1 SD) between the two alignments were 0.06+/-0.37, 0.10+/-0.86, and 0.39+/-1.27 mm in the lateral, longitudinal (SI), and vertical (AP) directions, respectively. Laterally, there was no difference>or=3 mm. The cumulative frequency of SI differences were as follows; >or=3 mm: 3%, >or=4 mm: 1%, and >or=5 mm: 1% (maximum: 5 mm). The cumulative frequency of AP differences were as follows; >or=3 mm: 7%, and >or=4 mm: 3% (maximum: 4 mm). CONCLUSION: In patients with prostate cancer receiving postoperative radiotherapy, the prostate bed motion relative to the pelvic bony anatomy is of a relatively small magnitude. Significant motion (>or=3 mm) is infrequent. However, small differences between the prostate bed and the bony anatomy still exist. This might have implications on treatment margins when daily alignment on bony anatomy is performed.

Humans↗

Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy.

The incorporation of daily images into the radiotherapy process leads to adaptive radiation therapy (ART), in which the treatment is evaluated periodically and the plan is adaptively modified for the remaining course of radiotherapy. Deformable registration between the planning image and the daily images is a key component of ART. In this paper, we report our researches on deformable registration between the planning kVCT and the daily MVCT image sets. The method is based on a fast intensity-based free-form deformable registration technique. Considering the noise and contrast resolution differences between the kVCT and the MVCT, an 'edge-preserving smoothing' is applied to the MVCT image prior to the deformable registration process. We retrospectively studied daily MVCT images from commercial TomoTherapy machines from different clinical centers. The data set includes five head-neck cases, one pelvis case, two lung cases and one prostate case. Each case has one kVCT image and 20-40 MVCT images. We registered the MVCT images with their corresponding kVCT image. The similarity measures and visual inspections of contour matches by physicians validated this technique. The applications of deformable registration in ART, including 'deformable dose accumulation', 'automatic re-contouring' and 'tumour growth/regression evaluation' throughout the course of radiotherapy are also studied.

Algorithms↗

Optimal number of beams for stereotactic body radiotherapy of lung and liver lesions.

PURPOSE: The aim of this study was to determine the optimal number of coplanar and noncoplanar external beams in the setting of stereotactic body radiotherapy (SBRT). METHODS AND MATERIALS: Spherical targets were delineated within 2 separate extracranial sites, the lung and liver, with diameters varying from 2 cm to 7 cm to cover the range of volumes used in SBRT. Treatment plans were created for all target volumes using 5 to 15 geometrically optimized coplanar and noncoplanar conformal beams. Dose gradient and normal tissue complication probability (NTCP) were evaluated for each set of beam configurations and for each target size. RESULTS: For all lung and liver target volumes, the dose gradient improved with an increase in beam number from 5 to 15 for both coplanar and noncoplanar beam configurations. NTCP decreased as the beam number increased from 5 to 9 beams for all target sizes for both coplanar and noncoplanar beams. There is no significant improvement in NTCP when more than 9 beams were used for treatment planning regardless of target size. CONCLUSION: Based on dosimetric criteria, the optimal number of external beams is 13 to 15 for SBRT using either coplanar or noncoplanar beam bouquets. Simple biologic models indicate that the optimal number of beams is 9 for SBRT of lung and liver lesions >2 cm, whereas smaller lesions may benefit from plans using up to 13 beams.

Algorithms↗

Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy.

PURPOSE: To report on the initial clinical use of a commercially available system to deliver gated treatment using implanted fiducials, in-room kV X-rays, and an infrared camera tracking system. METHODS AND MATERIALS: ExacTrac Adaptive Gating from BrainLab is a localization system using infrared cameras and X-rays. Gating signals are the patient's breathing pattern obtained from infrared reflectors on the patient. kV X-rays of an implanted fiducial are synchronized to the breathing pattern. After localization and shift of the patient to isocenter, the breathing pattern is used to gate the radiation. Feasibility tests included localization accuracy, radiation output constancy, and dose distributions with gating. Clinical experience is reported on treatment of patients with small lung lesions. RESULTS: Localization accuracy of a moving target with gating was 1.7 mm. Dose constancy measurements showed insignificant change in output with gating. Improvements of dose distributions on moving targets improved with gating. Eleven patients with lung lesions were implanted with 20 mmx0.7 mm gold coil (Visicoil). The implanted fiducial was used to localize and treat the patients with gating. Treatment planning and repeat computed tomographic scans showed that the change in center of gross target volume (GTV) to implanted marker averaged 2.47 mm due in part to asymmetric tumor shrinkage. CONCLUSION: ExacTrac Adaptive Gating has been used to treat lung lesions. Initial system evaluation verified its accuracy and usability. Implanted fiducials are visible in X-rays and did not migrate.

Calibration↗

Evaluation of two tomotherapy-based techniques for the delivery of whole-breast intensity-modulated radiation therapy.

PURPOSE: To evaluate two different techniques for whole-breast treatments delivered using the Hi-ART II tomotherapy device. METHODS AND MATERIALS: Tomotherapy uses the standard rotational helical delivery. Topotherapy uses a stationary gantry while delivering intensity-modulated treatments. CT scans from 5 breast cancer patients were used. The prescription dose was 50.4 Gy. RESULTS: On average, 99% of the target volume received 95% of prescribed dose with either technique. If treatment times are restricted to less than 9 min, the average percentage ipsilateral lung receiving > or =20 Gy was 22% for tomotherapy vs. 10% for topotherapy. The ipsilateral lung receiving > or =50.4 Gy was 4 cc for tomotherapy vs. 27 cc for topotherapy. The percentage of left ventricle receiving > or =30 Gy was 14% with tomotherapy vs. 4% for topotherapy. The average doses to the contralateral breast and lung were 0.6 and 0.8 Gy, respectively, for tomotherapy vs. 0.4 and 0.3 Gy for topotherapy. CONCLUSIONS: Tomotherapy provides improved target dose homogeneity and conformality over topotherapy. If delivery times are restricted, topotherapy reduces the amount of heart and ipsilateral lung volumes receiving low doses. For whole-breast treatments, topotherapy is an efficient technique that achieves adequate target uniformity while maintaining low doses to sensitive structures.

Breast↗

A technique for adaptive image-guided helical tomotherapy for lung cancer.

PURPOSE: The gross tumor volume (GTV) for many lung cancer patients can decrease during the course of radiation therapy. As the tumor reduces in size during treatment, the margin added around the GTV effectively becomes larger, which can result in the excessive irradiation of normal lung tissue. The specific goal of this study is to evaluate the feasibility of using image-guided adaptive radiation therapy to adjust the planning target volume weekly based on the previous week's CT image sets that were used for image-guided patient setup. METHODS AND MATERIALS: Megavoltage computed tomography (MVCT) images of the GTV were acquired daily on a helical tomotherapy system. These images were used to position the patient and to measure reduction in GTV volume. A planning study was conducted to determine the amount of lung-sparing that could have been achieved if adaptive therapy had been used. Treatment plans were created in which the target volumes were reduced after tumor reduction was measured. RESULTS: A total of 158 MVCT imaging sessions were performed on 7 lung patients. The GTV was reduced by 60-80% during the course of treatment. The tumor reduction in the first 60 days of treatment can be modeled using the second-order polynomial R = 0.0002t(2) - 0.0219t + 1.0, where R is the percent reduction in GTV, and t is the number of elapsed days. Based on these treatment planning studies, the absolute volume of ipsilateral lung receiving 20 Gy can be reduced between 17% and 23% (21% mean) by adapting the treatment delivery. The benefits of adaptive therapy are the greatest for tumor volumes > or =25 cm3 and are directly dependent on GTV reduction during treatment. CONCLUSIONS: Megavoltage CT-based image guidance can be used to position lung cancer patients daily. This has the potential to decrease margins associated with daily setup error. Furthermore, the adaptive therapy technique described in this article can decrease the volume of healthy lung tissue receiving above 20 Gy. However, further study is needed to determine whether adaptive therapy could result in the underdosing of microscopic extension.

Carcinoma, Non-Small-Cell Lung↗

Serial therapy-induced changes in tumor shape in cervical cancer and their impact on assessing tumor volume and treatment response.

OBJECTIVE: The purpose of this study was to evaluate the patterns and distribution of tumor shape and its temporal change during radiation therapy (RT) in cervical cancer and the effect of tumor configuration changes on the correlation between region of interest (ROI)-based and diameter-based MRI tumor measurement. MATERIALS AND METHODS: Serial MRI examinations (T1-weighted and T2-weighted images) were performed in 60 patients (age range, 29-75 years; mean, 53.3 years) with advanced cervical cancer (stages IB2-IVB/recurrent) who were treated with RT at four time points: start of RT, during RT (at 2-2.5 and at 4-5 weeks of RT), and post-RT. Tumor configuration was classified qualitatively into oval, lobulated, and complex based on MR film review. Two methods of tumor volume measurement were compared: ellipsoid computation of three orthogonal diameters (diameter based) and ROI volumetry by delineating the entire tumor volume on the MR workstation (ROI based). Temporal changes of tumor shape and the respective tumor volumes measured by the two methods were analyzed using linear regression analysis. RESULTS: Most tumors (70%) had a non-oval (lobulated and complex) shape before RT and became increasingly irregular during and after RT: 84% at 2-2.5 weeks of RT (p = 0.037), 86% (p = 0.025) at 4-5 weeks, and 96% post-RT (p = 0.010), compared with 70% pre-RT. Diameter-based and ROI-based measurement correlated well before RT (r = 0.89) but not during RT (r = 0.68 at 2-2.5 weeks, r = 0.67 at 4-5 weeks of RT). CONCLUSION: Most cervical cancers are not oval in shape pretherapy, and they become increasingly irregular during and after therapy because of nonconcentric tumor shrinkage. ROI-based volumetry, which can optimally measure irregular volumes, may provide better response assessment during treatment than diameter-based measurement.

Adenocarcinoma↗

Intraprostatic fiducials for localization of the prostate gland: monitoring intermarker distances during radiation therapy to test for marker stability.

PURPOSE: The use of intraprostatic fiducials as surrogates for prostate gland position assumes that the markers are rigidly positioned within the prostate. To test this assumption, the intermarker distances (IMD) of implanted markers was monitored during the full course of radiation therapy to determine marker stability within the prostate gland. METHODS AND MATERIALS: The analysis is performed on 56 patients treated with intensity-modulated radiotherapy. A total of 168 markers (3 markers per patient) were implanted. Two high-resolution X-rays were acquired before treatment delivery to visualize the position of the implanted markers. A total of 2,037 daily alignments were performed on the 56 cases (average: 36 alignments per patient). Each pair of X-ray images allows the computation of the 3 IMDs. A total of 6,111 IMDs were available for analysis. To study variations in marker position, daily IMDs were compared with the IMD that was observed during the first alignment. We defined the variation in the IMD as the important measure of intrinsic marker position variation. The standard deviation (SD) of IMD variations was studied as a measure of the extent of marker position variation. Particular attention was given to cases in which significant intermarker variations were observed. RESULTS: The average directional variation of all IMDs (+/- SD) was -0.31 (+/-1.41) mm. The average absolute variation of all IMDs (+/- SD) was 1.01 (+/-1.03) mm. The largest observed variation in IMD was 10.2 mm. Among the individual 56 patients, the SDs of the IMD variations were computed and found to range from 0.4 to 4.2 mm. In 54 of the 56 patients (96%), the variations of all 3 IMDs had SD of 4.0 mm or less, which indicates little variation in the relative position of the markers. Only in 2 patients did any of the IMDs vary, with SD that exceeded 4.0 mm, which indicated noticeable and consistent marker-position variation. The maximum observed SD in the IMD variation was 4.2 mm. In each of the 2 cases, 2 IMDs were found to fluctuate, while the third IMD remained fairly constant. This finding means that 1 of 3 markers varied frequently in its relative position throughout the treatment. Therefore, only 2 of the 168 markers (1%) showed frequent changes in their relative positions. A review of these 2 cases revealed that the observed marker mobility was likely not caused by migration of the marker itself but caused by prostate deformation, secondary to rectal filling. To investigate the frequency of extreme situations, the maximum observed IMD variation was determined for each patient. In 47 of the 56 patients (84%), the maximum difference in IMDs was at least 2 mm. The corresponding numbers for 3, 4, and 5 mm were 23 (41%), 10 (18%), and 5 (9%) patients, respectively. CONCLUSION: This study is the largest reported series of localized prostate cancer patients with implanted intraprostatic markers used for daily target localization in which individual marker positions were registered and IMDs were computed to test for marker position variation. Only 2 of 168 implanted markers showed a relatively significant and consistent change in their relative position throughout a course of treatment. However, these variations in position were most likely not caused by marker migration but caused by prostate deformation. Typically, the IMDs varied minimally, which indicated relatively little deformation of the gland as well as the absence of significant marker migration. However, during a typical course of treatment, the IMD is likely to vary by several millimeters in some instances, which indicates infrequent but significant deformation. In these instances, an alignment based on the 3 markers' center of mass will still provide a meaningful alignment of the prostate within the radiation field. Intraprostatic implanted fiducials in the prostate allow a reliable and simple localization of the prostate gland, even in the presence of organ deformation.

Humans↗

Initial experience with megavoltage (MV) CT guidance for daily prostate alignments.

PURPOSE: The on-board megavoltage (MV) computed tomography (CT) capabilities of a TomoTherapy Hi*ART unit were used to obtain daily MVCT images of prostate cancer patients. For patient alignment the daily MVCT image needs to be registered with the planning CT image to calculate couch shifts. Three manual techniques of registering the MVCT images with the planning kilovoltage (kV) CT images were evaluated. The techniques are based on visual alignment of (1) fiducial prostate markers, (2) CT anatomy, and (3) kVCT contours. METHODS AND MATERIALS: One hundred and twelve alignments from 3 patients were available for analysis. The radiation therapists visually registered the MVCT images with the planning kVCT images based on fiducial markers for actual patient alignment. Retrospectively, the therapists registered each image set using anatomy and contour-based techniques. In addition to the therapists, a physician retrospectively registered each image set based on each of the three techniques. For each MVCT to kVCT image pair a reference alignment was computed from the center-of-mass (COM) of the three fiducial markers. All registration results were compared with these reference alignments. The physician's image registrations were compared with the radiation therapists' registrations to assess the user variability of the different techniques. RESULTS: The marker-based registration results agree best with the reference alignments, while the contour-based registrations show the least degree of agreement. Using anatomy and contour-based registrations, the radiation therapist's alignments differed by > or = 3 mm from the reference alignments in 24%, 33%, and 3% and 55%, 48%, and 21% of all registrations in the anterior-posterior, superior-inferior, and lateral directions, respectively. The respective values for the marker-based alignments were 3%, 6%, and 3%. The physician's registrations showed the same general trend. The marker-based registrations showed the least amount of inter-user variability while the contour-based ones showed the most. CONCLUSION: The use of fiducial markers for MVCT image guidance is advantageous to reduce the inter-user variability of the image registration. If fiducial markers are not used, anatomy-based registrations outperform contour-based registrations in terms of (1) agreement with a reference alignment and (2) inter-user variability.

Calibration↗

Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: observations on tumor regression during treatment.

PURPOSE: The ability to obtain soft-tissue imaging in the treatment room, such as with megavoltage CT imaging, enables the observation of tumor regression during a course of external beam radiation therapy. In this current study, we report on the most extensive study looking at the rate of regression of non-small-cell lung cancers during a course of external beam radiotherapy by analyzing serial megavoltage CT images obtained on 10 patients. METHODS AND MATERIALS: The analysis is performed on 10 patients treated with the Helical Tomotherapy Hi*Art device. All 10 patients had non-small-cell lung cancer. A total of 274 megavoltage CT sets were obtained on the 10 patients (average, 27 scans per patient; range, 9-35). All patients had at least a scan at beginning and at the end of treatment. The frequency of scanning was determined by the treating physician. The treatment was subsequently delivered with the Tomotherapy Hi*Art system. The gross tumor volumes (GTVs) were later contoured on each megavoltage CT scan, and tumor volumes were calculated. Although some patients were treated to draining nodal areas in addition to the primary tumor, only the primary GTVs were tracked. Response to treatment was quantified by the relative decrease in tumor volume over time, i.e., elapsed days from the first day of therapy. The individual GTVs ranged from 5.9 to 737.2 cc in volume at the start of treatment. In 6 of the 10 patients, dose recalculations were also performed to document potential variations in delivered doses within the tumors. The megavoltage CT scans were used, and the planned treatment was recalculated on the daily images. The hypothesis was that dose deposited in the target would increase throughout the course of radiotherapy because of tumor shrinkage and subsequent decreasing attenuation. Specifically, the dose received by 95% of the GTV (D95) was monitored over time for each of the 6 patients treated at M. D. Anderson Cancer Center Orlando. RESULTS: Regression of all 10 lung tumors could be observed on the serial megavoltage CT scans. The decrease in volume was observed at a relatively constant rate throughout the treatments, with no obvious initial or final plateaus. For all 10 tumors, the average decrease in volume was 1.2% per day. However, individual tumor regression rates were observed with a range of 0.6% to 2.3% per day. The lowest rate of shrinkage was observed for the smallest lesion, and the highest rate was observed in the largest lesion. Of the 6 cases in which dose recalculations were performed, 5 demonstrated a small but noticeable gradual increase in deposited doses within the tumor, with the D95 increases ranging from 0.02% to 0.1% per day. CONCLUSION: With the advent of in-room soft-tissue imaging techniques such as megavoltage CT imaging with a helical tomotherapy unit, daily documentation of the status of a grossly visible targeted tumor becomes possible. The current study demonstrated that tumor regression can be documented for patients with non-small-cell lung cancer treated with helical tomotherapy. Clinical correlations between the observations made during the course of treatment and ultimate outcomes, e.g. local control, should be investigated.

Carcinoma, Non-Small-Cell Lung↗

A geometrically based method of step and shoot stereotactic radiosurgery with a miniature multileaf collimator.

Conventional methods of inverse planning for intensity-modulated radiotherapy (IMRT) and intensity-modulated radiosurgery (IMRS) are generally based upon optimizing a set of beam fluence profiles according to a set of dose-volume constraints specified by a human planner. This optimization is generally carried out through an iterative approach that relies upon the optimization of a score, driving the plan's ability to satisfy the user-provided constraints. Following optimization of the fluence distribution, the non-trivial problem of converting the fluence distribution into a set of deliverable, intensity-modulated beams must be solved. A novel approach to solving this IMRS total inverse problem is presented in this paper. The proposed method uses a class solution that provides an optimized dose gradient and a method of designing a conformal plan based on an existing geometrically based optimization algorithm. After developing an optimal fluence distribution, the process then arranges the fluence into a set of simple and efficient MLC beam delivery sequences. The algorithm presented here offers several potential advantages for the application of intensity modulation to radiosurgery treatment planning. The geometrically based optimization process' simplicity requires far less human user input and decision making in the specification of dose and dose-volume constraints than do conventional inverse planning algorithms. This simplicity allows the optimization process to be completed much faster than conventional inverse-planning algorithms, literally seconds compared with at least several minutes. Likewise, the fluence conversion step is a simplified process (compared to conventional IMRT planning), which takes advantage of some simplifications uniquely appropriate to the problem at hand (IMRS). The converted, deliverable IMRS beams allow superior conformity and dose gradient relative to conventional IMRS planning or 3DCRT radiosurgery planning. Another benefit is that the number of beam intensity levels is greatly reduced, from hundreds to as few as a half-dozen intensity levels. Finally, since the treatment plan optimization process is based upon proven principles applicable to optimizing radiosurgery (rather than the general problem of optimizing fractionated radiotherapy plans), the plans generated and deliverable with this method of IMRS are potentially superior to those produced by conventional inverse-planning methods of IMRT/IMRS.

Algorithms↗

Initial clinical experience with frameless radiosurgery for patients with intracranial metastases.

PURPOSE: To review the initial clinical experience with frameless stereotactic radiosurgery (SRS) for treating intracranial metastatic disease. METHODS AND MATERIALS: Sixty-four patients received frameless SRS for intracranial metastatic disease. Minimum follow-up was 6 months with none lost to follow-up. Patients had a median of 2 metastases and a maximum of 4. The median number of isocenters was 2 with median arcs of 10 and median dose of 17.5 Gy. Thirteen patients were treated for progressive/recurrent disease after surgical resection or whole brain radiotherapy (WBRT). Fifty-one patients were treated with frameless SRS as an an adjunct to initial treatment. Of the total treated, 17 were treated with SRS alone, 20 were treated with WBRT plus SRS, 16 were treated with surgical resection plus SRS, and the remaining 11 were treated with surgical resection plus WBRT plus SRS. RESULTS: With a median actuarial follow-up period of 8.2 months, ultimate local control was 88%. The median time to progression was 8.1 months. The median overall survival was 8.7 months. Of the 17 patients treated with SRS alone, 86% had ultimate local control with mean overall survival of 7.1 months. Of the 13 patients who received surgical resection plus SRS without WBRT as primary treatment, there was 85% ultimate local control with an overall survival of 10.3 months. Three patients treated with initial surgery alone had recurrence treated with SRS 2-3 months after resection. All these patients obtained local control and median survival was >10 months. Of the 13 patients who received WBRT followed by SRS as boost treatment, 92% had local control and mean overall survival was 7.3 months. Of 7 patients who received SRS after recurrence after WBRT, 100% had local control with median survival of 8.2 months. For 8 patients who received surgery followed by WBRT and SRS, local control was 50%; however, ultimate intracranial control was achieved in 7 of 8 patients with repeat SRS and surgical resection. The overall survival in this group of patients was 14.7 months. No patient had a serious (Grade 3 or higher) complication requiring intervention. CONCLUSIONS: Frameless optically guided radiosurgery is less invasive, can be performed as a standard radiotherapy-based simulation procedure, and maintains submillimetric accuracy. Our initial results with frameless SRS for metastatic disease suggest survival times and local control (88%) eqiuvalent to frame-based methodologies. Practical noninvasive delivery makes treatment and potential retreatment to avoid WBRT more feasible.

Adult↗

Optically guided patient positioning techniques.

Optical tracking determines an object's position by measuring light either emitted or reflected from the object. The hallmark of optical tracking systems is their high spatial resolution and measurement in real time; such systems can resolve the position of a point source within a fraction of a millimeter and report at a rate of 10 Hz or faster. Several systems have been developed for radiation therapy, all of which track infrared markers attached to the patient's external surface. The positions of the optical markers relative to the target volume, together with the desired marker positions relative to treatment isocenter, are determined during computed tomography simulation. In the treatment room, the real marker positions are measured relative to isocenter; rigid-body mathematics then determine marker displacements from their desired positions and hence target displacement from isocenter. Real-time feedback allows one to correct the patient's position. The first systems were used for intracranial stereotaxis radiotherapy; rigid arrays of optical markers were attached to the patient via a biteplate linkage. Subsequent systems for extracranial radiotherapy tracked external markers to determine patient position and/or gate the radiation beam based on patient motion. Lastly, optical tracking has been integrated with ultrasound or stereoscopic x-ray imaging to determine the position of internal anatomy targets relative to isocenter.

Humans↗

Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit.

Helical tomotherapy is an innovative means of delivering IGRT and IMRT using a device that combines features of a linear accelerator and a helical computed tomography (CT) scanner. The HI-ART II can generate CT images from the same megavoltage x-ray beam it uses for treatment. These megavoltage CT (MVCT) images offer verification of the patient position prior to and potentially during radiation therapy. Since the unit uses the actual treatment beam as the x-ray source for image acquisition, no surrogate telemetry systems are required to register image space to treatment space. The disadvantage to using the treatment beam for imaging, however, is that the physics of radiation interactions in the megavoltage energy range may force compromises between the dose delivered and the image quality in comparison to diagnostic CT scanners. The performance of the system is therefore characterized in terms of objective measures of noise, uniformity, contrast, and spatial resolution as a function of the dose delivered by the MVCT beam. The uniformity and spatial resolutions of MVCT images generated by the HI-ART II are comparable to that of diagnostic CT images. Furthermore, the MVCT scan contrast is linear with respect to the electron density of material imaged. MVCT images do not have the same performance characteristics as state-of-the art diagnostic CT scanners when one objectively examines noise and low-contrast resolution. These inferior results may be explained, at least partially, by the low doses delivered by our unit; the dose is 1.1 cGy in a 20 cm diameter cylindrical phantom. In spite of the poorer low-contrast resolution, these relatively low-dose MVCT scans provide sufficient contrast to delineate many soft-tissue structures. Hence, these images are useful not only for verifying the patient's position at the time of therapy, but they are also sufficient for delineating many anatomic structures. In conjunction with the ability to recalculate radiotherapy doses on these images, this enables dose guidance as well as image guidance of radiotherapy treatments.

Computer Systems↗

Geometrically based optimization for extracranial radiosurgery.

For static beam conformal intracranial radiosurgery, geometry of the beam arrangement dominates overall dose distribution. Maximizing beam separation in three dimensions decreases beam overlap, thus maximizing dose conformality and gradient outside of the target volume. Webb proposed arrangements of isotropically convergent beams that could be used as the starting point for a radiotherapy optimization process. We have developed an extracranial radiosurgery optimization method by extending Webb's isotropic beam arrangements to deliverable beam arrangements. This method uses an arrangement of N maximally separated converging vectors within the space available for beam delivery. Each bouquet of isotropic beam vectors is generated by a random sampling process that iteratively maximizes beam separation. Next, beam arrangement is optimized for critical structure avoidance while maintaining minimal overlap between beam entrance and exit pathways. This geometrically optimized beam set can then be used as a template for either conformal beam or intensity modulated extracranial radiosurgery. Preliminary results suggest that using this technique with conformal beam planning provides high plan conformality, a steep dose gradient outside of the tumour volume and acceptable critical structure avoidance in the majority of clinical cases.

Computer Simulation↗

A simple and reliable index for scoring rival stereotactic radiosurgery plans.

PURPOSE: A simple and robust index for ranking rival stereotactic radiosurgery plans is presented. METHODS: The radiosurgery plan score index, CGI (Conformity/Gradient Index), is an average of a conformity score and a gradient score. Computation of the CGI score is simple, requiring only three pieces of data: (1) the total volume irradiated to the prescription isodose level, (2) the volume of the target, and (3) the total volume irradiated at half of the prescription isodose level. The overall CGI Index is a simple function of these three pieces of data. RESULTS: When multiple sets of rival stereotactic radiosurgery plans were ranked with respect to this single score index, the resulting plan rankings closely matched the plan rankings according to biologic indices (calculated nontarget brain normal tissue complication probabilities). CONCLUSIONS: The CGI is a simple and fast plan evaluation tool that can assist the radiosurgery planner in evaluating and optimizing multiple candidate radiosurgery plans.

Adult↗

Does prone positioning reduce small bowel dose in pelvic radiation with intensity-modulated radiotherapy for gynecologic cancer?

PURPOSE: Intensity-modulated radiotherapy (IMRT) has been shown to reduce the radiation dose to small bowel in pelvic RT in gynecology patients. Prone positioning has also been used to decrease small bowel dose by displacement of small bowel from the RT field in these patients. The purpose of this study was to determine whether the combination of both IMRT and prone positioning on a belly board can reduce small bowel dose further in gynecologic cancer patients undergoing pelvic RT. METHODS AND MATERIALS: IMRT plans for pelvic RT were computed in 16 patients with gynecologic cancer who had undergone planning CT scans in both the supine and the prone positions on a belly board. For the gross tumor volume, the uterus, cervix, and tumor (or postoperative region) were traced. The clinical target volume was defined as the vessels and lymph nodes from the obturator level to the aortic bifurcation, presacral region, and upper 4 cm of the vagina, in addition to gross tumor volume. The planning target volume was defined as a 2-cm margin in addition to the gross tumor volume and upper 4 cm of the vagina, and 1.5 cm for lymph nodes and vessels. Normal tissue regions of interest included small bowel, large bowel, and bladder. IMRT plans using (1) the limited arc technique (180 degrees arc length) and (2) the extended arc technique (340 degrees arc length) were computed. Dose-volume histograms for normal tissue structures and target were compared between the supine and prone IMRT plans using the paired t test. RESULTS: Prone positioning on a belly board decreased the small bowel dose in gynecologic pelvic IMRT, and the magnitude of improvement depended on the specific IMRT technique used. With the limited arc technique, prone positioning significantly decreased the irradiated small bowel volume at the 25-50-Gy dose levels compared with supine positioning. Small bowel volumes receiving > or =45 Gy decreased from 19% to 12.5% (p = 0.005) with prone positioning. With the extended arc technique, the decrease in irradiated small bowel volume was less marked, but remained detectable in the 35-45-Gy dose levels. Small bowel volumes receiving > or =45 Gy decreased from 13.6% to 10.1% (p = 0.03) with prone positioning. The effect of prone positioning on large bowel and bladder was variable. Large bowel volumes receiving > or =45 Gy increased with prone positioning from 16.5% to 20.6% (p = 0.02) in the limited arc technique and was unaffected in the extended arc technique. CONCLUSION: These preliminary data suggest that prone positioning on a belly board can reduce the small bowel dose further in gynecology patients treated with pelvic RT, and that the dose reduction depends on the IMRT technique used.

Adult↗

Ultrasound-guided extracranial radiosurgery: technique and application.

PURPOSE: Stereotactic radiosurgery is an effective treatment modality for many intracranial lesions, but target mobility limits its utility for extracranial applications. We have developed a new technique for extracranial radiosurgery based on optically guided three-dimensional ultrasound (3DUS). The 3DUS system provides the ability to image the target volume and critical structures in real time and determine any misregistration of the target volume with the linear accelerator. In this paper, we describe the system and its initial clinical application in the treatment of localized metastatic disease. METHODS AND MATERIALS: The extracranial stereotactic system consists of an ultrasound unit that is optically tracked and registered with the linear accelerator coordinate system. After an initial patient positioning based on computed tomographic (CT) simulation, stereotactic ultrasound images are acquired and correlated with the CT-based treatment plan to determine any soft-tissue shifts between the time of the planning CT and the actual treatment. Optical tracking is used to correct any patient offsets that are revealed by the real-time imaging. RESULTS: Preclinical testing revealed that the ultrasound-based stereotactic navigation system is accurate to within 1.5 mm in comparison with an absolute coordinate phantom. Between March 2001 and March 2002, the system was used to deliver extracranial radiosurgery to 17 metastatic lesions in 16 patients. Treatments were delivered in 1 or 2 fractions, with an average fractional dose of 16 Gy (range 12.5-24 Gy) delivered to the 80% isodose surface. Before each fraction, the target misalignment from isocenter was determined using the 3DUS system and the misalignments averaged over all patients were anteroposterior = 4.8 mm, lateral = 3.6 mm, axial = 2.1 mm, and average total 3D displacement = 7.4 mm (range = 0-21.0 mm). After correcting patient misalignment, each plan was delivered as planned using 6-11 noncoplanar fields. No acute complications were reported. CONCLUSIONS: A system for high-precision radiosurgical treatment of metastatic tumors has been developed, tested, and applied clinically. Optical tracking of the ultrasound probe provides real-time tracking of the patient anatomy and allows computation of the target displacement before treatment delivery. The patient treatments reported here suggest the feasibility and safety of the technique.

Aged↗