PubMed Health⌕ Search

Biomedical subjects

Sang-Hee Choi

Publications and source records attributed to Sang-Hee Choi.

5 recordsLinked to original sources

Angiogenesis: noninvasive quantitative assessment with contrast-enhanced functional US in murine model.

PURPOSE: To evaluate quantitative functional ultrasonography (US) in a murine gel model by using microbubble destruction kinetics to determine whether parametric indices provided with US could help assess angiogenesis. MATERIALS AND METHODS: Institutional Animal Subjects Committee approved experiments and procedures. In 36 normal mice, two 0.4-mL gel implants were placed subcutaneously on either side of spine. One implant contained 0.5, 1.0, or 1.5 microg human basic fibroblast growth factor (bFGF) per milliliter of gel. Functional US quantitative analysis of angiogenesis with microbubble contrast agent was performed on days 3, 6, 9, and 12; histologic data were collected. Time-intensity curve of implant was fitted to mathematic decay model to calculate fractional blood volume and fraction of blood replaced per unit of time. Microvascular density (MVD) and percentage of microvascular area (MVA) were measured after anti-CD31 staining. Spearman rank order correlation was used in analyses. RESULTS: bFGF-containing implants induced MVD of eight, 35, 42, and 42 vessels per square millimeter on days 3, 6, 9, and 12, respectively; in controls, MVD was four vessels/mm2 (P<.05 on days 6, 9, and 12). bFGF-containing implants induced percentage MVA of 2%, 5%, 20%, and 27%, respectively; in controls, it was 0.5% (P<.05). Maximum enhancement was significantly increased in bFGF implants (23.3 gray level+/-14.1 [standard deviation]) compared with controls (11.0+/-5.5, P<.001). Implants containing bFGF showed poor correlations between fractional blood volume and MVD (r2=0.42) or percentage MVA (r2=0.51) at US. There was no correlation between microbubble velocity and MVD (r2<0.05) or percentage MVA (r2<0.13). CONCLUSION: Functional US perfusion parameters do not correlate with current histologic indices for quantifying angiogenesis. MVD, as a histologic quantitative measurement of angiogenesis, may not be an appropriate standard for contrast-enhanced imaging that relies on perfused neovessels.

Animals↗

Angiogenesis model for ultrasound contrast research: exploratory study.

RATIONALE AND OBJECTIVES: To optimize an angiogenesis model for imaging research that is stable and can be imaged several times over the angiogenic time course. MATERIALS AND METHODS: Mice and rats received two injections of 0.4 mL of extract of basement membrane matrix (Matrigel; Becton Dickinson Labware, Bedford, MA) in the subcutaneous spaces on either side of the spine. One of the two Matrigel plugs in each animal had either 0.1 microg/mL of basic fibroblast growth factor (bFGF) (11 mice), 1.0 microg/mL of bFGF (12 mice, 5 rats), or 1.0 microg/mL of bFGF and 60 U/mL of heparin (11 mice). Three to 12 days after implantation, animals were imaged before and after the administration of up to four injections of 0.1 mL AF0150. Phase inversion imaging was used on a Siemens Elegra (Siemens ultrasound, Issaquah, WA) equipped with a 13 MHz VFX transducer. Three observers subjectively assessed the pattern of enhancement using a four-point scale. The Matrigel plugs were then removed and two observers graded the angiogenic response on a four-point scale. Ten Matrigel plugs, five with 1.0 microg/mL bFGF and five without, were evaluated histologically following immunohistochemical staining with anti-CD31. RESULTS: The angiogenic response was greater in Matrigel plugs with 1.0 than with 0.1 microg/mL of bFGF. Heparin did not increase the angiogenic response. Vessels were predominantly at the periphery of the plugs with variable central penetration. Plugs appeared anechoic and homogeneous on ultrasound. Contrast enhancement within the plug occurred in 44% of mice with an angiogenic response at or after day 6 and the enhancement increased with the angiogenic response. In the others, peripheral enhancement could not be distinguished from the enhancement of surrounding tissues that were also hyperemic. The thicker rat skin interfered with plug assessment. CONCLUSION: A stable angiogenesis model without the complexity of tumors is described. This model offers the opportunity to image the development and/or inhibition of angiogenesis. Neovasculature in Matrigel was detectable using ultrasound contrast. Quantitative studies correlating the degree of enhancement to microvascular density will be determined in subsequent studies.

Animals↗

Model to quantify lymph node enhancement on indirect sonographic lymphography.

OBJECTIVE: Our goal was to develop a reliable technique that has minimal operator dependence for quantifying lymph node enhancement to test and optimize new sonography contrast formulations. MATERIALS AND METHODS: Twenty healthy rabbits were studied using five agents, labeled A-G. Agents D and E were the same agent and agents F and G were Imagent, studied blindly to test reproducibility. One milliliter of contrast agent was injected into each hind footpad. A 13-MHz transducer was fixed over the popliteal node, which was imaged at a 4.8-MHz central transmit frequency using phase-inversion technology at 100% power and one frame per second. Immediately after each injection, the footpad was massaged 12 times for 30 sec each time and then imaged after each massage to assess the number of times the node could be refilled from each injection. Lymph node video intensity was measured, and the degree of enhancement was evaluated using analysis of variance with the massage number and the agent used as independent variables. RESULTS: Lymph node enhancement was observed after the first massage with all agents. Degree of enhancement was least with agents A and B, intermediate with agents D and F, and greatest with agent C. Agent A was effective after the first two massages, agent B after the first four, agent C after all 12, agent D after the first eight, and agent F after the first nine. Performance of agents D and F was similar to that of their duplicates, E and G. CONCLUSION: We established a reproducible technique to quantify lymph node enhancement that can distinguish between different agents. The differences in performance suggest that it is possible to optimize agent formulation for indirect sonographic lymphography.

Analysis of Variance↗

Validation of ultrasound contrast destruction imaging for flow quantification.

Our purpose was to validate in vitro a kinetic flow model based on microbubble signal decay curve. Using a 3.5 MHz transducer and phase-inversion (1.8 MHz central transmit frequency), a renal dialysis cartridge oriented vertically was imaged in the transverse plane as 1:1000 dilution of AF0150 was infused at 50, 100, 200, 300 and 400 mL/min. Ten gray-scale images were acquired at each infusion rate using 2.5, 5 and 10 frames/s at 100%, 40%, 15% or 1% of maximum transmit power. Video-intensity measured on each 10 images was fit to a kinetic model using Sigma Plot that yielded microbubble concentration, velocity and destruction per frame. These were correlated with the experimental conditions. At 100% power, video-intensity on the first frame (microbubble concentration at equilibrium) was similar for all flow and frame rates. The model fit the experimental data for all flows at 10 frames/s and for flows lower than 400 and 100 mL/min at 5 frames/s and 2.5 frames/s, respectively. The calculated flow was similar to the experimental flow rates, regardless of technique (r(2) = 0.98). Microbubble fraction destroyed per frame was similar for all flow and frame rates and increased linearly with transmit power (r(2) > 0.98). These results suggest that using appropriate power and frame rate for a given flow rate, estimates of fractional blood volume, flow and destruction fraction can be calculated from the decay curve using 10 frames that can be acquired in 1 to 4 s.

Contrast Media↗

Usefulness of multidetector-row CT in the evaluation of reperfused myocardial infarction in a rabbit model.

OBJECTIVE: To evaluate the usefulness of multidetector-row computed tomography(CT) in the evaluation of reperfused myocardial infarction. MATERIALS AND METHODS: Eleven rabbits were subjected to 90-min occlusion of the left anterior descending coronary artery followed by reperfusion. Multidetector-row CT was performed 31 hours+/-21 after the procedure and pre and post-contrast multiphase helical CT images were obtained up to 10 min after contrast injection. The animals were sacrificed after 30 days and histochemical staining of the resected specimens was performed with 2'3'5-triphenyl tetrazolium chloride (TTC). RESULTS: In all 11 cases, the areas of myocardial infarction demonstrated with TTC-staining were identified on the CT images and the lesions showed hypoenhancement on the early phases up to 62 sec and hyperenhancement on the delayed phases of 5 min and 10 min compared with normal myocardial enhancement. The percentage area of the lesion with respect to the left ventricle wall on CT was significantly correlated with that of the TTC-staining results (p < 0.001 for both early and delayed phase CT) according to the generalized linear model analysis. The areas showing hypoenhancement on early CT were significantly smaller than those with hyperenhancement on delayed CT (p < 0.0001). CONCLUSION: Multidetector-row CT may be useful in the detection and sizing of reperfused myocardial infarction.

Animals↗