Interactive MR imaging and tracking of catheters with multiple tuned fiducial markers.

PURPOSE: The lack of magnetic resonance (MR) safe catheters and guide wires remains an important obstacle to widespread clinical use of MR-guided endovascular procedures. The authors looked at the feasibility of using multiple tuned fiducial markers (TFM) and novel imaging sequences to track catheters reliably under MR and to evaluate the safety of such markers in terms of heating. MATERIALS AND METHODS: The visualization and tracking of a catheter with six quadrature tuned fiducial coils was carried out in a special designed in-vitro setup within a 1.5-T MR imager simulating an MR-guided endovascular intervention. The fiducial markers were also tested for heating. RESULTS: The excellent signal contrast between the fiducial and the background when using novel interleaved real time and interactive sequences allowed for rapid and reliable identification of the fiducial markers and therefore the catheter. No significant heating of the marker was noted. CONCLUSIONS: The authors have shown that catheters with multiple tuned fiducial markers are superior to passive catheter designs in terms of visualization and do not carry the risk of heating that is commonly associated with active catheters.

Cardiac Catheterization↗

Measurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterization.

Pulmonary hypertensive disease is assessed by quantification of pulmonary vascular resistance. Pulmonary total arterial compliance is also an indicator of pulmonary hypertensive disease. However, because of difficulties in measuring compliance, it is rarely used. We describe a method of measuring pulmonary arterial compliance utilizing magnetic resonance (MR) flow data and invasive pressure measurements. Seventeen patients with suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment underwent MR-guided cardiac catheterization. Invasive manometry was used to measure pulmonary arterial pressure, and phase-contrast MR was used to measure flow at baseline and at 20 ppm nitric oxide (NO). Total arterial compliance was calculated using the pulse pressure method (parameter optimization of the 2-element windkessel model) and the ratio of stroke volume to pulse pressure. There was good agreement between the two estimates of compliance (r = 0.98, P < 0.001). However, there was a systematic bias between the ratio of stroke volume to pulse pressure and the pulse pressure method (bias = 61%, upper level of agreement = 84%, lower level of agreement = 38%). In response to 20 ppm NO, there was a statistically significant fall in resistance, systolic pressure, and pulse pressure. In seven patients, total arterial compliance increased >10% in response to 20 ppm NO. As a population, the increase did not reach statistical significance. There was an inverse relation between compliance and resistance (r = 0.89, P < 0.001) and between compliance and mean pulmonary arterial pressure (r = 0.72, P < 0.001). We have demonstrated the feasibility of quantifying total arterial compliance using an MR method.

Adolescent↗

A system for real-time XMR guided cardiovascular intervention.

The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sliding table XMR configuration. The aim of our recent work was to extend our technique by providing an improved calibration stage, real-time guidance during cardiovascular catheterization procedures, and further off-line analysis for mapping cardiac electrical data to patient anatomy. Specially designed optical trackers and a dedicated calibration object have resulted in a single calibration step that can be efficiently checked and updated before each procedure. An X-ray distortion model has been implemented that allows for distortion correction for arbitrary c-arm orientations. During procedures, the guidance system provides a real-time combined MR/X-ray image display consisting of live X-ray images with registered recently acquired MR derived anatomy. It is also possible to reconstruct the location of catheters seen during X-ray imaging in the MR derived patient anatomy. We have applied our registration technique to 13 cardiovascular catheterization procedures. Our system has been used for the real-time guidance of ten radiofrequency ablations and one aortic stent implantation. We demonstrate the real-time guidance using two exemplar cases. In a further two cases we show how off-line analysis of registered image data, acquired during electrophysiology study procedures, has been used to map cardiac electrical measurements to patient anatomy for two different types of mapping catheters. The cardiologists that have used the guidance system suggest that real-time XMR guidance could have substantial value in difficult interventional and electrophysiological procedures, potentially reducing procedure time and delivered radiation dose. Also, the ability to map measured electrical data to patient specific anatomy provides improved visualization and a path to investigation of cardiac electromechanical models.

Cardiac Catheterization↗

Novel method of quantifying pulmonary vascular resistance by use of simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow.

BACKGROUND: Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. METHODS AND RESULTS: In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to -45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to -66.0%). CONCLUSIONS: We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.

Adolescent↗

Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients.

Passive catheter tracking involves direct interaction between the device and its surroundings, creating a local signal loss or enhancement of the image. Using only standard balloon catheters filled with CO(2) and imaged with a steady-state free precession sequence, it was possible to visualize and passively track catheters in a flow phantom and in the heart and great vessels of 20 patients without any additional image processing. The phantom work demonstrated that it was advantageous to sacrifice spatial resolution in order to increase temporal resolution. Frame rates greater than 10/sec were necessary for ease of catheter manipulation. Although only the tip of the catheter was visualized, this technique proved to be effective in patients undergoing cardiac catheterization.

Adolescent↗

Catheter tracking and visualization using 19F nuclear magnetic resonance.

This work presents an investigation into catheter visualization and localization using 19F nuclear magnetic resonance (NMR) in conjunction with proton imaging. For this purpose, the imaging capabilities of a standard system were extended to allow for 19F excitation and signal detection. Two modes of operation were implemented: 1) a real-time tracking mode that provides tip tracking and automatic slice position updates interleaved with real-time, interactive proton imaging; and 2) a non-real-time catheter length visualization mode in which the entire length of a catheter can be assessed. Initial phantom experiments were conducted with the use of an angiographic balloon catheter filled with the blood substitute perfluorooctylbromide (PFOB). Using limited bandwidth excitation centered at the resonances of the CF2 groups of PFOB, we found that sufficient signal could be received to facilitate tip tracking during catheter motion and length visualization for various catheter configurations. The present approach is considered a promising alternative to existing methods, which either are associated with safety concerns (if active markers are employed) or suffer from insufficient, direction-dependent contrast (if passive visualization is used). Furthermore, our approach enables visualization of the entire length of the catheter. The proposed method provides a safe technique that, unlike electrical or optical devices, does not require modification of commercially available catheters.

Catheterization↗

Cardiac catheterisation guided by MRI in children and adults with congenital heart disease.

BACKGROUND: Fluoroscopically guided cardiac catheterisation is an essential tool for diagnosis and treatment of congenital heart disease. Drawbacks include poor soft tissue visualisation and exposure to radiation. We describe the first 16 cases of a novel method of cardiac catheterisation guided by MRI with radiographic support. METHODS: In our cardiac catheterisation laboratory, we combine magnetic resonance and radiographic imaging facilities. We used MRI to measure flow and morphology, and real-time MRI sequences to visualise balloon angiographic catheters. 12 patients underwent diagnostic cardiac catheterisation, two had interventional cardiac catheterisations, and for two patients, MRI was used to plan radiofrequency ablation for treatment of tachyarrhythmias. FINDINGS: In 14 patients, some or all of the cardiac catheterisation was guided by MRI. In two patients undergoing radiofrequency ablation, catheters were manipulated with use of fluoroscopic guidance and outcome was assessed with MRI. All patients received lower amounts of radiation than controls. There was some discrepancy between pulmonary vascular resistance calculated by flow derived from MRI and the traditional Fick method. We were able to superimpose fluoroscopic images of electro physiology electrode catheters on the three dimensional MRI of the cardiac anatomy. INTERPRETATION: We have shown that cardiac catheterisation guided by MRI is safe and practical in a clinical setting, allows better soft tissue visualisation, provides more pertinent physiological information, and results in lower radiation exposure than do fluoroscopically guided procedures. MRI guidance could become the method of choice for diagnostic cardiac catheterisation in patients with congenital heart disease, and an important tool in interventional cardiac catheterisation and radiofrequency ablation.

Adult↗

Registration and tracking to integrate X-ray and MR images in an XMR facility.

We describe a registration and tracking technique to integrate cardiac X-ray images and cardiac magnetic resonance (MR) images acquired from a combined X-ray and MR interventional suite (XMR). Optical tracking is used to determine the transformation matrices relating MR image coordinates and X-ray image coordinates. Calibration of X-ray projection geometry and tracking of the X-ray C-arm and table enable three-dimensional (3-D) reconstruction of vessel centerlines and catheters from bi-plane X-ray views. We can, therefore, combine single X-ray projection images with registered projection MR images from a volume acquisition, and we can also display 3-D reconstructions of catheters within a 3-D or multi-slice MR volume. Registration errors were assessed using phantom experiments. Errors in the combined projection images (two-dimensional target registration error--TRE) were found to be 2.4 to 4.2 mm, and the errors in the integrated volume representation (3-D TRE) were found to be 4.6 to 5.1 mm. These errors are clinically acceptable for alignment of images of the great vessels and the chambers of the heart. Results are shown for two patients. The first involves overlay of a catheter used for invasive pressure measurements on an MR volume that provides anatomical context. The second involves overlay of invasive electrode catheters (including a basket catheter) on a tagged MR volume in order to relate electrophysiology to myocardial motion in a patient with an arrhythmia. Visual assessment of these results suggests the errors were of a similar magnitude to those obtained in the phantom measurements.

Adolescent↗