PubMed Health⌕ Search

Biomedical subjects

Sanli Ergun

Publications and source records attributed to Sanli Ergun.

2 recordsLinked to original sources

Coherent array imaging using phased subarrays. Part II: simulations and experimental results.

The basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing the number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging--which uses only one element per firing event--and full-phased array (FPA) imaging-which uses all elements for each firing. The performance of PSA generally ranges between that obtained by CSA and FPA using the same array, and depends on the amount of hardware complexity reduction. For the work described in this paper, we performed FPA, CSA, and PSA imaging of a resolution phantom using both simulated and experimental data from a 3-MHz, 3.2-cm, 128-element capacitive micromachined ultrasound transducer (CMUT) array. The simulated system point responses in the spatial and frequency domains are presented as a means of studying the effects of signal bandwidth, reconstruction filter size, and subsampling rate on the PSA system performance. The PSA and FPA sector-scanned images were reconstructed using the wideband experimental data with 80% fractional bandwidth, with seven 32-element subarrays used for PSA imaging. The measurements on the experimental sector images indicate that, at the transmit focal zone, the PSA method provides a 10% improvement in the 6-dB lateral resolution, and the axial point resolution of PSA imaging is identical to that of FPA imaging. The signal-to-noise ratio (SNR) of PSA image was 58.3 dB, 4.9 dB below that of the FPA image, and the contrast-to-noise ratio (CNR) is reduced by 10%. The simulated and experimental test results presented in this paper validate theoretical expectations and illustrate the flexibility of PSA imaging as a way to exchange SNR and frame rate for simplified front-end hardware.

Computer Simulation↗

Medical imaging using capacitive micromachined ultrasonic transducer arrays.

We are investigating the use of capacitive micromachined ultrasonic transducers (cMUT's) for use in medical imaging. We propose an ultrasound probe architecture designed to provide volumetric ultrasound imaging from within an endoscope channel. A complete automated experimental system has been implemented for testing the imaging performance of cMUT arrays. This PC-based system includes custom-designed circuit boards, a software interface, and resolution test phantoms. We have already fabricated 1D and 2D cMUT arrays, and tested the pulse-echo imaging characteristics of 1D arrays. Beamforming and image formation algorithms that aim to reduce the complexity of data acquisition hardware are tested via numerical simulations and using real data acquired from our system.

Journal Article↗