PubMed Health⌕ Search

Biomedical subjects

Sanne Engelen

Publications and source records attributed to Sanne Engelen.

2 recordsLinked to original sources

Robust PCA and classification in biosciences.

MOTIVATION: Principal components analysis (PCA) is a very popular dimension reduction technique that is widely used as a first step in the analysis of high-dimensional microarray data. However, the classical approach that is based on the mean and the sample covariance matrix of the data is very sensitive to outliers. Also, classification methods based on this covariance matrix do not give good results in the presence of outlying measurements. RESULTS: First, we propose a robust PCA (ROBPCA) method for high-dimensional data. It combines projection-pursuit ideas with robust estimation of low-dimensional data. We also propose a diagnostic plot to display and classify the outliers. This ROBPCA method is applied to several bio-chemical datasets. In one example, we also apply a robust discriminant method on the scores obtained with ROBPCA. We show that this combination of robust methods leads to better classifications than classical PCA and quadratic discriminant analysis. AVAILABILITY: All the programs are part of the Matlab Toolbox for Robust Calibration, available at http://www.wis.kuleuven.ac.be/stat/robust.html.

Algorithms↗

Lack of fluorophotometric evidence of aqueous-vitreous barrier disruption after posterior capsulorhexis.

PURPOSE: To evaluate the integrity of the aqueous-vitreous barrier by assessing the flow of fluorescein from the anterior chamber to the anterior vitreous using fluorophotometry in eyes with a posterior continuous curvilinear capsulorhexis (PCCC) and in eyes without a PCCC. SETTING: University Hospital Antwerp, Edegem, Belgium. METHODS: Ten patients had bilateral extracapsular cataract extraction with implantation of an intraocular lens. In 1 eye, a PCCC was performed; the other eye served as a negative control. The eyes of 2 other patients who had complicated cataract surgery with posterior capsule and anterior hyaloid membrane rupture served as positive controls. All patients had fluorophotometry of both eyes 12 to 18 months after surgery to measure the flow of fluorescein from the anterior chamber to the anterior vitreous. RESULTS: There were no statistically significant differences in the distribution pattern of fluorescein between eyes with PCCC and eyes without PCCC. In contrast, enhanced flow was detected in both eyes with rupture of the posterior capsule and the anterior hyaloid. CONCLUSIONS: In this fluorophotometry study, a PCCC did not seem to disrupt the aqueous-vitreous barrier. Results indicate that an intact anterior vitreous membrane is crucial to maintain the barrier function between the anterior and the posterior segments of the eye.

Aged↗