PubMed Health⌕ Search

Biomedical subjects

Sara Rodriguez-Mozaz

Publications and source records attributed to Sara Rodriguez-Mozaz.

6 recordsLinked to original sources

Biosensors as useful tools for environmental analysis and monitoring.

Recent advances in the development and application of biosensors for environmental analysis and monitoring are reviewed in this article. Several examples of biosensors developed for relevant environmental pollutants and parameters are briefly overviewed. Special attention is paid to the application of biosensors to real environmental samples, taking into consideration aspects such as sample pretreatment, matrix effects and validation of biosensor measurements. Current trends in biosensor development are also considered and commented on in this work. In this context, nanotechnology, miniaturisation, multi-sensor array development and, especially, biotechnology arise as fast-growing areas that will have a marked influence on the development of new biosensing strategies in the near future.

Animals↗

Automated water analyser computer supported system (AWACSS) Part I: Project objectives, basic technology, immunoassay development, software design and networking.

A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe. This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods.

Algorithms↗

Automated Water Analyser Computer Supported System (AWACSS) Part II: Intelligent, remote-controlled, cost-effective, on-line, water-monitoring measurement system.

A novel analytical system AWACSS (Automated Water Analyser Computer Supported System) based on immunochemical technology has been evaluated that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration or pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) [98/83/EC, 1998. Council Directive (98/83/EC) of 3 November 1998 relating to the quality of water intended for human consumption. Off. J. Eur. Commun. L330, 32-54] and Water Framework Directive (WFD) [2000/60/EC, 2000. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy. Off. J. Eur. Commun. L327, 1-72], drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The first part article gave the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods. The systems' capability for analysing a wide range of environmental organic micro-pollutants, such as modern pesticides, endocrine disrupting compounds and pharmaceuticals in surface, ground, drinking and waste water is shown. In addition, a protocol using reconstitution of extracts of solid samples, developed and applied for analysis of river sediments and food samples, is presented. Finally, the overall performance of the AWACSS system in comparison to the conventional analytical techniques, which included liquid and gas chromatographic systems with diode-array UV and mass spectrometric detectors, was successfully tested in an inter-laboratory collaborative trial among six project partners.

Algorithms↗

Picogram per liter level determination of estrogens in natural waters and waterworks by a fully automated on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry method.

The present work describes a novel, fully automated method, based on on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry (SPE-LC-ESI-MS-MS), which allows the unequivocal identification and quantification of the most environmentally relevant estrogens (estradiol, estrone, estriol, estradiol-17-glucuronide, estradiol-17-acetate, estrone-3-sulfate, ethynyl estradiol, diethylstilbestrol) in natural and treated waters at levels well below those of concern (limits of quantification between 0.02 and 1.02 ng/L). The method is highly precise, with relative standard deviations varying between 1.43 and 3.89%, and accurate (recovery percentages >74 %). This method was used to track the presence and fate of the target compounds in a waterworks and to evaluate the removal efficiency of the treatment processes applied. Only estrone and estrone-3-sulfate were detected in the river water used as source (at 0.68 and 0.33 ng/L, respectively). After progressive removal through the various treatment steps, none of them were detected in the finished drinking water. In addition to selectivity, sensitivity, repeatability, and automation (up to 15 samples plus 6 calibration solutions and 1 blank can be analyzed unattended), this technique offers fairly high throughput (analysis time per sample is 60 min), low time and solvent consumption, and ease of use.

Autoanalysis↗

Monitoring of estrogens, pesticides and bisphenol A in natural waters and drinking water treatment plants by solid-phase extraction-liquid chromatography-mass spectrometry.

A multi-residue analytical method has been developed for the determination of various classes of selected endocrine disruptors. This method allows the simultaneous extraction and quantification of different estrogens (estradiol, estrone, estriol, estradiol-17-glucuronide, estradiol diacetate, estrone-3-sulfate, ethynyl estradiol and diethylstilbestrol), pesticides (atrazine, simazine, desethylatrazine, isoproturon and diuron), and bisphenol A in natural waters. In the method developed, 500 ml of water are preconcentrated on LiChrolut RP-18 cartridges. Further analysis is carried out by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure chemical ionisation (APCI) in the positive ion mode for determination of pesticides and electrospray in the negative ionisation mode for determination of estrogens and bisphenol A. Recoveries for most compounds were between 90 and 119%, except for bisphenol A (81%) and diethylstilbestrol (70%), with relative standard deviations below 20%. Limits of detection ranged between 2 and 15 ng/l. The method was used to study the occurrence of the selected pollutants in surface and groundwater used for abstraction of drinking water in a waterworks and to evaluate the removal efficiency of the different water treatments applied. Water samples from the river, the aquifer, and after each treatment stage (sand filtration, ozonation, activated carbon filtration and post-chlorination) were taken monthly from February to August of 2002. The presence in river water of atrazine, simazine, diuron and bisphenol A were relatively frequent at concentrations usually below 0.1 microg/l. Lower levels, below 0.02 microg/l, were usual for isoproturon. Estrone-3-sulfate and estrone were detected occasionally in the river. Most of the compounds were completely removed during the water treatment, especially after activated carbon filtration.

Benzhydryl Compounds↗

Biosensors for environmental monitoring of endocrine disruptors: a review article.

This article provides an overview of the applications of biosensors in analysis and monitoring of endocrine-disrupting compounds (EDCs) in the environment. Special attention is devoted to the various types of physical-chemical signal transduction elements, biological mechanisms employed as sensing elements and techniques used for immobilisation of the bioreceptor molecules on the transducer surface. Two different classes of biosensors for EDCs are considered: biosensors that measure endocrine-disrupting effects, and biosensors that respond to the presence of a specific substance (or group of substances) based on the specific recognition of a biomolecule. Several examples of them are presented to illustrate the power of the biosensor technology for environmental applications. Future trends in the development of new, more advanced devices are also outlined.

Biosensing Techniques↗