PubMed Health⌕ Search

Biomedical subjects

Sarah A Mutch

Publications and source records attributed to Sarah A Mutch.

3 recordsLinked to original sources

Proton permeation into single vesicles occurs via a sequential two-step mechanism and is heterogeneous.

This article describes the first single-vesicle study of proton permeability across the lipid membrane of small (approximately 100 nm) uni- and multilamellar vesicles, which were composed of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC). To follow proton permeation into the internal volume of each vesicle, we encapsulated carboxyfluorescein, a pH-sensitive dye whose fluorescence was quenched in the presence of excess protons. A microfluidic platform was used for easy exchange of high- and low-pH solutions, and fluorescence quenching of single vesicles was detected with single-molecule total internal reflection fluorescence (TIRF) microscopy. Upon solution exchange and acidification of the extravesicular solution (from pH 9 to 3.5), we observed for each vesicle a biphasic decay in fluorescence. Through single-vesicle analysis, we found that rate constants for the first decay followed a Poisson distribution, whereas rate constants for the second decay followed a normal distribution. We propose that proton permeation into each vesicle first arose from formation of transient pores and then transitioned into the second decay phase, which occurred by the solubility-diffusion mechanism. Furthermore, for the bulk population of vesicles, the decay rate constant and vesicle intensity (dependent on size) correlated to give an average permeability coefficient; however, for individual vesicles, we found little correlation, which suggested that proton permeability among single vesicles was heterogeneous in our experiments.

Cell Membrane Permeability↗

Layered polyelectrolyte-silica coating for nanocapsules.

This paper demonstrates the ability to grow silica directly on a deposited surface of polyelectrolyte. Using this strategy, we describe the deposition of layered polyelectrolyte-silica coating on negatively charged surfaces of polystyrene particles and latex nanocapsules, which could not be coated directly with silica alone. By etching away the underlying polystyrene bead, we were able to form polyelectrolyte-silica capsules that were mechanically robust. Using scanning and transmission electron microscopy, we imaged and studied the coating after the deposition of each layer of polyelectrolyte and silica. We then applied this new coating to latex nanocapsules that were loaded with fluorescein molecules. We found that the coating procedure did not cause the loaded molecules to leak out from the capsules, and we determined that the variation in the number of loaded molecules among capsules arose from differences in the volume of the nanocavities and was not caused by the loading and coating of the capsules. This layered architecture permits the thickness of the coating to be controlled in principle over a wide dynamic range, but more importantly, this coating could act as an effective seal to prevent undesired leakage from nanocapsules and thus increase the long-term storability of loaded capsules. Over a 30-day period, we determined that leakage from uncoated capsules was significant but negligible for ones that were coated with two layers of polyelectrolyte-silica. Using single-pulse UV photolysis of individual nanocapsules, we demonstrate that the molecules contained within coated capsules could be released effectively and on demand with a single laser pulse.

Journal Article↗

Direct manipulation and observation of the rotational motion of single optically trapped microparticles and biological cells in microvortices.

This paper describes a method for manipulating and monitoring the rotational motion of single, optically trapped microparticles and living cells in a microvortex. To induce rotation, we placed the microparticle at the center of rotation of the vortex and used the recirculating fluid flow to drive rotation. We have monitored the rotation of single beads (which ranged in diameter from a few micrometers to tens of micrometers) and living cells in a microvortex. To follow the rotation of a smooth and symmetrically shaped bead, we first ablated a small region ( approximately 1 microm) on the bead. An Ar(+) laser was then tightly focused ( approximately 0.5-microm spot size) onto the bead, and rotation was tracked by recording changes in the level of backscattered laser light as the ablated region repeatedly transited the laser focus. Using this method, we have followed bead rotation that varied in frequency from 0.15 to 100 Hz and have studied the effect of bead diameter on the rate of rotation at a given fluid flow rate. To monitor the rotation of single living cells, we selectively stained portions of B-lymphocytes with the fluorescent dye DiOC(6). We observed rotation by following changes in the fluorescence signal as the dye-stained region transited the laser focal volume. This technique provides a simple and sensitive method for controlling and monitoring the rotational motion of microparticles in a microfluidic environment.

Animals↗