Is optimal paddle force applied during paediatric external defibrillation?

INTRODUCTION: Optimal paddle force minimises transthoracic impedance; a factor associated with increased defibrillation success. Optimal force for the defibrillation of children < or =10 kg using paediatric paddles has previously been shown to be 2.9 kgf, and for children >10 kg using adult paddles is 5.1 kgf. We compared defibrillation paddle force applied during simulated paediatric defibrillation with these optimal values. METHODS: 72 medical and nursing staff who would be expected to perform paediatric defibrillation were recruited from a University teaching hospital. Participants, blinded to the nature of the study, were asked to simulate defibrillation of an infant manikin (9 months of age) and a child manikin (6 years of age) using paediatric or adult paddles, respectively, according to guidelines. Paddle force (kgf) was measured at the time of simulated shock and compared with known optimal values. RESULTS: Median paddle force applied to the infant manikin was 2.8 kgf (max 9.6, min 0.6), with only 47% operators attaining optimal force. Median paddle force applied to the child manikin was 3.8 kgf (max 10.2, min 1.0), with only 24% of operators attaining optimal force. CONCLUSION: Defibrillation paddle force applied during paediatric defibrillation often falls below optimal values.

Body Weight↗

What is the optimal paddle force during paediatric external defibrillation?

INTRODUCTION: Transthoracic impedance (TTI) is a major determinant of transmyocardial current flow, and therefore, the success of defibrillation. European Resuscitation Council (ERC) paediatric guidelines recommend that 'firm' paddle force should be applied to the paddles during defibrillation. No study has yet established the optimal paddle force required to minimise TTI in children of different ages. METHODS: Eighty patients aged 10 weeks to 17 yrs undergoing general anaesthesia for routine surgery were studied. Using defibrillation paddles placed in an anterior-apical position, TTI (Omega) was measured for increasing values of force from 0.5 kgf (baseline) to 6.5 kgf. The optimal force, the force to achieve 95% of the overall reduction in TTI, was then determined. According to current guidelines, paediatric paddles (surface area 16 cm2) were used for infants (< or =10 kg) and adult paddles (82 cm2) for older children. Optimal force was then calculated for infants < or =10 kg, children >10 kg and < or =8 yrs and children 9-17 yrs age. RESULTS: Increasing paddle force from 0.5 kgf progressively decreased TTI. Optimal force using paediatric paddles was 2.9 kgf in infants. Optimal force using adult paddles was 5.1 kgf in children >10 kg but < or = 8 yrs and 5.3 kgf in children aged 9-17 yrs. CONCLUSIONS: Force is an important determinant of TTI and therefore, outcome of defibrillation. It is recommended that a minimum of 3 kgf be applied to paddles when defibrillating infants with paediatric paddles, and a minimum of 5 kgf be applied to all older children when adult paddles are used.

Adolescent↗